ML20049A353

From kanterella
Jump to navigation Jump to search
Forwards Info Verifying Adequacy of Spent Fuel Transfer Cask Redundant Support Assembly.Results of Verification Confirm Adequacy of Redundant Support Assembly
ML20049A353
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 12/05/1980
From: Withrow G
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML20049A354 List:
References
NUDOCS 8012150285
Download: ML20049A353 (2)


Text

.

77... TV33 9
consumers 4

n Power

(

f Company r 2.+

General Offices: 212 West Michigan Avenue Jackson, Mich:gan 49201 * (517) 788-0550 December 5, 1980 Director, Nuclear Reactor Regulation Att Mr Dennis M Lutchfield, Chief Operating Reactors Branch No 5 US Nuclear Rec 11atory Commission Washington, DC 20555 DOCKET 50-155 - LICENSE DPR BIG ROCK POINT PLANT -

2h-TON SPENT FUEL TEMISFER L.3K REDUNDA*IT SUPPORT ASSE' GLY Consumers Power Company letter dated Noventer 8,1976 notified the NRC of our intent not to proceed with modifications for mitigation of cask drops as presented in our submittal dated July 1,197h. This change in intent was pre-

'cipitated by the knowledge that the 60-ton spent fuel shipping cask (which was the basis for the ma,jority of the proposed modifications) would not be used in the foreseeable future.

This change in policy was considered acceptable for the 2h-ton spent fuel trans-fer cask, because it has a redundant support (safety sling) assembly that was designed to catch the cask in the event of a main hoist / hook failure. The 2h-ten spent fuel transfer cask redundant support system adequacy was established by a review of vendor drawings and the original purchase specification.

Recently, additional documentation of the design of the transfer cask redundant support system was sought. A review of plant records and the manufacturer's files indicated that the original design documentation coula no longer be re-trieved. The vendor indicated that it was not their practice to maintain design records for such a long period of time (approximately 20 years). Therefore, a verification of the adequacy of the redundant support system was performed. The results of this verification ( Attachment 1 - performed by MPR Associates, Inc) confirmed the adequacy of the spent fuel transfer cask redundant support system.

He manufacturer of the redundant support system (Whiting Corporation) has con-firmed the MPR Associates. Inc conclusicn.

i 80 1215011$

1

Lennis M Crutchfieldo Chief 2

December 5, 1980 Big Rock Point Plant Ten (10) and three (3) copies of Attachment 1 (MPR Associates Inc letter (P-54h) from JWJohnson to GCWithrow, dated November 26, 1980) are being submitted to NRR and I&E, respectively.

Gregory C Withrow (Signed)

Gregory C Withrov Senior Licensing Engineer CC JGKeppler, USNRC NRC Resident Inspector - Big Rock Point