Corrected 6.2.3.4 of TS Page 6-6 to Amend 83 to License NPF-38
ML20046C368
Person / Time
Site: Waterford 
Issue date: 08/04/1993
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20046C369 List:
References
NUDOCS 9308100192
Download: ML20046C368 (2)


Text

.

TABLE 6.2-1 HINIMUM SHIFT CREW COMPOSITION POSITION NUMBER OF INDIVIDUALS REQUIRED TO FILL POSITION MODE 1, 2, 3, OR 4 MODE 5 OR 6 SS 1*

1 SR0 1*

None R0 2

1 A0 2

1 STA 1*

None l

SS Shift Supervisor with a Senior Operator License SRO -

Individual with a Senior Operator License R0 Individual with an Operator License AO Auxiliary Operator STA -

Shift Technical Advisor Except for the Shift Supervisor, the shift crew composition may be one less than the minimum requirements of Table 6.2-1 for a period of time not to exceed 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> in order to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew composi-tion to within the minimum requirements of Table 6.2-1.

This provision does not permit any shift crew position to be unmanned upon shift change due to an oncoming shift crewman being late or absent.

During any absence of the Shift Supervisor from the control room while the unit is in MODE 1, 2, 3 or 4, an individual (other than the Shift Technical Advisor) with a valid Senior Operator license shall-be designated to assume the control room command function. During any absence of the Shift Supervisor

'from the control room while the unit is in MODE 5 or 6, an individual with a valid Senior Operator or Operator license shall be designated to assume the control room command function.

  • An individual with SR0/STA qualifications can satisfy the SS/STA or SR0/STA position requirements simultaneously.

WATERFORD - UNIT 3 6-5 AMENDMENT N0. 7 9308100192 930804 PDR ADOCK 05000302 P

PDR

v 0

ADMINISTRATIVE CONTROLS 6.2.3 INDEPENDENT TECHNICAL REVIEWS FUNCTICN 6.2.3.1 Independent technical reviews shall be conducted to examine plant operating characteristics, NRC issuances, industry advisories, Licensee Event Reports and other sources of plant design and operating experience information which may indicate areas for improving plant safety.

COMPOSITION 6.2.3.2 A minimum of five, full-time engineers shall be dedicated to perform the independent technical review functions described herein.

Each shall have a Bachelor's Degree in Engineering or Physical Science or equivalent and at least two years professional level experience in his/her field.

RESPONSIBILITIES 6.2.3.3 Independent technical review responsibilities shall encompass surveillance to independently verify

  • that these activities are performed safely and correctly and that human errors are reduced as much as practical.

AUTHORITY 6 2.3.4 Individuals assigned the authority to perform the functions and responsibilities delineated above shall make detailed recommendations for revised procedures, equipment modifications, maintenarce activities, operations activities, or other means of improving unit safety.

RECORDS 6.2.3.5 Written records of the activities described above shall be maintained.

Recommendations for improving unit safety shall be forwarded each calendar month to the Director of Nuclear Safety.

6.2.4 SHIFT TECHNICAL ADVISOR 6.2.4.1 The Shift Technical Advisor shall provide advisory technical support to the Shift Supervisor in the areas of thermal hydraulics, reactor engineer-ing, and plant analysis with regard to the safe operation of the unit. The STA shall meet the requirements of either Option 1 or 2 as shown below:

4 a.

Option 1 - Combined SR0/STA Position. This option is satisfied by assigning an individual with the fellowing qualifications to each operating shift crew as one of the SR0's required by 10 CFR 50.54(m) (2) (1):

  • Not responsible for sign-off function.

WATERFORD - UNIT 3 6-6 AMENDMENT N0. 18 63r83 7