ML20046C182

From kanterella
Jump to navigation Jump to search
Forwards Unit 1 Refueling 20 ISI Summary Rept for Form NIS-1 & Unit 1 Refueling 20 Repair/Replacement Summary Rept for Form NIS-2. Repts Reflects ISI Activities During Third Outage of First Period of Third 10-yr Interval
ML20046C182
Person / Time
Site: Point Beach 
Issue date: 08/02/1993
From: Link B
WISCONSIN ELECTRIC POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20046C183 List:
References
CON-NRC-93-86 VPNPD-93-134, NUDOCS 9308090311
Download: ML20046C182 (1)


Text

1 Y

Wisconsin Electnc POWER COMPANY 231 w Mmom m R> 2046. Mamukee v4 53201 (4141 221-2345 VPNPD-93-134 NRC-93-86 August 2, 1993 Document Control Desk U.S.

NUCLEAR REGULATORY COMMISSION Mail Station P1-137 Washington, DC 20555 Gentlemen:

DOCKET 50-301 FILING OF OWNER'S INSERVICE INSPECTION

SUMMARY

REPORT POINT BEACH NUCLEAR PLANT, UNIT 1 Attached is the Owner's Inservice Inspection Summary Report which is submitted in accordance with ASME Section XI, IWA-6230.

Included in this submittal is the Inservice Inspection Summary Report for Form NIS-1 and the Repair / Replacement Summary Report for NIS-2.

The information contained in the report reflects the inservice inspection activities during the third outage of the first period of the third 10-year interval of Wisconsin Electric Power Company's Point Beach Nuclear Plant, Unit 1.

Sincerely,

< {/'

Bob Link Vice President Nuclear Power CTP/jg Attachment i

+

I

/

)V 9308090311 930802 P

gDR ADOCK 05000301' f3

_PDR y

Asubs&rrafHina@Dvm Onpade t-

r t

FORM NIS 1 OWNER'S REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner Wisconsin Electric Power Co., 231 W. Michigan, Milwaukee, WI 53201 (Name and Address of Owner)
2. Plant Point Beach Maclear PlanL 6610JAGlear_ Egad. Two Rivers. WT sa?al (Name and Address of Plant)
3. Plant Unit 1
4. Owner Certificate of Authorization (if required) Doc ke t_.50-26ft_
5. Commercial Service Date 1_2/21/70
6. National Board Number for Unit N/A
7. Components Inspected Manufacturer Compor ent er Manufacturer or Installer State or National Appurtenance or installer Serial No.

Province No.

Board No.

Reactor i

Pressure Vesse]

Babcock and Wilcox R-1 UO10615 NB 0138 A Reactor Coolant Pump Westinchouse 1-618J-741G01 A Steara Generator Westinchouse 16A-6339-1 UO10616 16A6079-1 Class 1 Pipino Systen Westinchouse l

Class 2 Piping Systen Westinghouse i

i t

t 1

t l

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, pro ioed (1) size is 8% in. x 11 in.,

{

{2) information in items I through 6 on this report isincluded on each sheet, and (3) each sheet is nurnbered and the number of sheetsis recorded at the top of this form.

i (12 M)

N f orm 200029) may be obisined from the Ortier Dept., AS!/E. 22 Law Drive, Dox 2300. Fairheid, NJ 07007-2300.

i l

m-i i

FORM NIS.1 (Back) t i

I

8. Examination Dates 05/31/92 to 05/05/93 9. Inspection Interval from.03 /27/93 to os/ns/93
10. Applicable Editions of Section XI 1986 Addenda None
11. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval.

Refer to attached Inservice Inspection Summary Report.

12. Abstract of Conditions Noted.

Refer to attached Inservice Inspection Summary Report.

13. Abstract of Corrective Measures Recommended and Taken, a

Refer to attached Inservice Inspection Summary Report.

.j l

We certify that the statements made in this report are correct and the examinations and corrective mea-l sures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authoriration No. (if applicable)NR_Q_ Dos];pt 50-2h1 Expiration Date N/A Wisconsin Electric

{

4 D a t e ___ _t^

19 Signed Power Company By gg, Owner

/

L CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Wisconsin and employed by HSBII, Co.

of Hartford, CT have inspected the components described in this Owner's Report during the period 1

05/31/92 to 05/05/93

, and state that to the best of my knowledge and belief, the Owner I

has performed examinations and taken corrective measures desenbed in this Owner's Report in accordance with the i

inspection plan and as required by the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection.

[-

Commissions

/47'7 8 /

M' 7 fr' N, M I Inspecfor's Sig/

a nature National Board, State, Province, and Endorsements 2

19 M Date __ 417 f

h l

I I

I

-l 1

i J

l

+