f' Public Service Electric and Gas Company
. Stanley LaBruna Public Service Electric and Gas Company P.O. Box 236, Hancocks Bridge, NJ 08038 609-339-1700 Vice Prescent - %ciear Ertgiree<ig JUL 2 01993 NLR-N93110 United States Nuclear Regulatory Commission Document Control Desk Washington, DC 20555 Gentlemen:
RESPONSE TO GENERIC LETTER 92-01, REVISION 1 REACTOR VESSEL STRUCTURAL INTEGRITY, 10CFR50. 54 ( f)
REQUEST FOR ADDITIONAL INFORMATION HOPE CREEK GENERATING STATION FACILITY OPERATING LICENSE No. NPF-57 DOCKET NO. 50-354 PSE&G submitted the response to Generic Letter 92-01, Revision 1 to the NRC in Letters NLR-N92080 dated June 30, 1992, and NLR-N92120 dated September 3, 1992.
By lettc; d?ted June-1, 1993', the NRC documented the results of their initial review of these' responses and requested'the following additional information:
Question ' 2a in GL 92-01 The NRC requested PSE&G to either confirm that the BWR Owners Group Topical Report on Upper Shelf Energy (USE)
Equivalent Margin Analysis (NEDO-32205) will be used as'part of the Hope Creek Licensing Basis or to provide a plant. specific approach to demonstrate that all beltline materials that do not have a measured USE meet the requirements of 10CFR50, Appendix G.
NEDO-32205 was submitted to'the NRC by the BWR Owners Group on April 30, 1993.
Upon review and approval of NEDO-32205 by the NRC,.PSE&G will incorporate the report as part of the licensing.
basis by amendment to the Hope Creek UFSAR.
Ouestion 2b in GL 92-01 The NRC requested PSE&G'to provide all plate and. weld Charpy.
~ test curves compiled by General Electric Corporation that were used'to establish the 2 Degree F per ft-lb slope for the.
nonn+n b
9307270147J9307po
{3 1}0 DR ADocx 05000354 W"
p
- PDR, k
A
'JUL 2 0' 1993 Document Control Desk 2
NLR-N93110 transition zone of the Charpy curve.
At the present time, the.
BWR Owners Group is completing a generic evaluation of.the test data used to establish the 2 Degree F per ft-lb slope. -This evaluation'is scheduled to be submitted to the NRC in August, 1993.
PSE&G is supporting the Owners Group efforts to complete this generic evaluation.
Upon submittal of the generic evaluation by the BWR Owners Group, and review and approval by the NRC of this report and NEDO-32205, PSE&G will incorporate both these reports as part of the licensing basis by amendment to the Hope Creek UFSAR.
Should you have any questions, please contact us.
Sincerely,
.) f// W -
=
Attachment Affidavit
+
C Mr.
T.
T. Martin, Administrator - Region I U.
S.
Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. S.
Dembek, Licensing Project Manager U.
S.
Nuclear Regulatory Commission One White Flint North 11555 Rockville Pike Rockville, MD 20852 Mr.
T. P. Johnson (SO9)
USNRC Senior Resident Inspector Mr. K.
Tosch, Manager, IV NJ Department of-Environmental Protection t
Division of Environmental Quality Bureau of Nuclear Engineering CN 415
-Trenton, NJ.
08625 t
+
b
.,.,?
REF: NLR-N93110 STATE OF NEW JERSEY
)
)
SS.
COUNTY OF SALEM
)
S.
LaBruna, being duly sworn according to law deposes and says:
I am Vice President - Nuclear Engineering of Public Service Electric and Gas Company, and as such, I find the matters set forth in the above referenced letter, concerning the Hope Creek.
Generating Station, are true to the best of my knowledge, information and belief.