'l
-l URANIUM RECOVERY PROGRAM POLICY AND GUIDANCE DIRECTIVE LLWM 93-02 1
STANDARD REVIEW PLAN FOR THE REVIEW OF REMEDIAL ACTION OF INACTIVE MILL TAILINGS SITES UNDER TITLE I OF THE URANIUM MILL TAILINGS RADIATION CONTROL ACT Revision 1 June 1993 RESPONSIBLE STAFF:
'RO ' 'D BY:
$l,tstdk.[
$bt Sandra Wastler LL R John Surmeier, Chief, LLUR APP,Rd7ED BY:
EWED BY:
/ lit ( p k f f-'4 wt.
Rithard Bangarti LLWM r;a f V.
D 1 M. Gillen, LLUR REVIEWED BY -
EFFECTIVE UNTIL: 10/95 1
F1 e LLUR Reevaluation Scheduled 6/95 LLWM 93-02 APPROVED: July 1,1993 3
)
I PURPOSE:
The Standard Review Plan (SRP) provides guidance to the NRC staff to assure that the review of DOE's Uranium Mill Tailings Remedial Action (UMTRA) Project documents are conducted in a thorough, focused, efficient, and consistent manner. The SRP also assures that the staff's findings are properly documented.
In addition, the SRP provides DOE, impacted states, Indian tribes, and other interested parties, with an understanding of the review process.
DISCUSSION:
The SRP allows for consistency between reviews and among reviewers in technical and regulatory matters related to the NRC review and concurrence in DOE's proposed remedial action at UMTRA sites. This is a revision to the SRP (formerly LLWM 92-09) to reflect comments by the Advisory Committee on Nuclear Waste.
In the absence of an SRP for Title II reclamation activities, this SRP should be used as guidance in that program to the extent practicable.
LIMITATIONS:
None l
PAGES IN REFERENCED DOCUMENT:
82, A-1, B-1, C-1 to C-4, and D-1 to 0-15 BIBLIOGRAPHIC CITATION:
" Standard Review Plan for the Review of Remedial Action of l
Inactive Mill Tailings Sites Under Title I of the Uranium i
Mill Tailings Radiation Control Act," Revision 1, LLWM, June 1993.
RESPONSIBLE STAFF:
Sandra L. Wastler, LLUR, 301-504-2582 1
i j
LL\\VA193-02 APPROVED: July 1,1993 PAGE 2 l
f 92-02
" Assessments and Audits: Low Level Waste Management (LLWM) Participation in Agreement State Reviews," LLWM, February 1992.
92-03
" Interim Guidance on Evaluation Procedure for Hydraulic Conductivity of Radon / Infiltration Barriers for Title I and Title II Mill Tailings Sites," Memorandum from J.J.
Surmeier to R.E. Hall, April 9, 1992.
92-04
" Guiding Principals for EPA-NRC Cooperation and Decisionmaking," March 1992.
92-05
" Air Sampling in the Workplace,"
Reg. Guide 8.25, Rev.
1, June 1992.
92-06
" Instructions for Recording and Reporting Occupational Radiation Exposure Data," Reg. Guide 8.7, Rev.1, June 1992.
92-07
" Radiation Dose to the Embryo / fetus," Reg. Guide 8.36,_
July 1992.
92-08
" Monitoring Criteria and Methods to Calculate Occupational Radiation Doses," Reg. Guide 8.34, July 1992.
92-09
" Standard Review Plan for UMTRCA Title I Mill Tailings Remedial Action Plans," Revision 1, LLWM, October, 1992.
SUPERSEDED BY 93-02.
92-10 "ALARA Levels For Effluents From Materials Facilities,"
Draft Reg. Guide.DC-8013, October 1992.
93-01 "On-Site Construction Reviews of Remedial Action At Inactive Uranium Mill Tailings Sites,"
Chapter 2620, Inspection and Enforcement Manual, Rev.
1, February 1993.
93-02
" Standard Review Plan for the Review of Remedial Action of Inactive Mill Tailings Sites Under Title I of the Uranium Mill Tailings Radiation Control Act," Rev.
1, June 1993.
LLWM-1 ISSUED: July 1,1993 Page 7
i LLUR shall incorporate review comments when feasible and reasonable efforts shall be made to resolve the differences.
For l
comments not incorporated, the reasons for non-accommodation shall be discussed with the Director, URF0, and the Director, Division of Radiation Safety and Safeguards, and documented in a record to the file that will be transmitted to the parties involved.
A copy of this record to the file will be permanently retained by the LLUR directive system custodian. (The LLUR directive system custodian will be designated by the Chief, LLUR upon implementation of the UR Program Policy and Directive System.)
5.0 CONCURRENCE For UR directives that have broader policy or legal implications, concurrence should be obtained from other NRC offices (e.g.,
Office of the General Council, Office of State Programs, Office of Enforcement, etc.) as appropriate. A concurrence block shall be provided on the Title Cover for such concurrence.
6.0 APPROVALS OF UR DIRECTIVES The Director, LLWM shall review and approve all proposed new or revised UR directives.
7.0 DISTRIBtffION OF UR DIRECTIVES Upon approval by the Director LLWM, the UR directive will be transmitted to URF0 and LLUR for implementation. Additional distribution will be made to usual LLWM and NMSS files; to the Director, DRSS, in Region IV. A copy also will be provided to the Public Document Room and the Advisory Committee on Nuclear Waste.
The Table of Contents and Indexes for the UR Policy and Guidance Directive System will be distributed by memorandum to all URF0 and LLUR staff when changes or additions are made to the system.
Any deleted directives from the system also will be identified in the above memorandum.
8.0 EFFECTIVE DATES OF AND REVISIONS TO UR DIRECTIVES 8.1 UR Directives.
The provisions of the initial set of UR directives will go into effect on June 1, 1993. All future UR directives will go into effect immediately upon approval by the Director LLWM. When a specific effective date is necessary because of a management determination or to satisfy a legal or administrative requirement, the effective date must be specified in the UR directive.
LLWM-2 APPROVED: June 1,1993 PAGE5
i s a
Title I 89-02, 89-03, 91-02, 92-03, 93-01, 93-02 Title II 92-03, 93-02 Waste Disposal 88-06, 91-03 i
LLWM-3 ISSUED: July 1,1993 Page
l 92-08 This guide-provides acceptable criteria that may be used by licensees to determine whether monitoring is needed and to provide methods for calculating and summing' external and internal doses to demonstrate compliance with the dose limits in 10 CFR 20.1201)a)(1) for adults and 10 CFR 20.1207 for minors.
92-09 Provides a standard review plan for Title I Remedial Action Plans.
SUPERSEDED BY 93-02.
92-10 Provides guidance on designing an acceptable prcgram for establishing and maintaining ALARA levels for gaseous and liquid effluents at materials facilities.
93-01 Provides guidance for construction reviews of remedial actions at Title I sites.
93-02 Provides a standard review plan for Title I Remedial Action Plans which is also to be used for Title II reviews to the extent practicable.
LLWM-4 ISSUED: July 1.1993 Page 7