Georg:a Power Cornpany 40 inverness Cener Parkwap Post othce Do< 1295 ~
Birrn7gnam A'abana 35201 Te:ephone 205 877 7122 l
m C. K. McCoy Georgia Power vce P:esdent Nuchnir July 12, 1993 me sounern ewrc usrem i
vo y e erw.m LCV-0079 Docket Nos. 50-424 50-425 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555 Gentlemen:
VOGTLE ELECTRIC GENERATING PLANT MONTHLY OPERATING REPORT Enclosed are the June 1993 monthly operating reports for Vogtle Units 1 and 2. These reports are submitted in accordance with Technical Specification 6.8.1.5.
Sincerely, I
C. K. McCoy
/
CKM/JLilgmb
/
Enclosure xc: Georgia Power Company Mr. J. B. Beasley Mr. M. Sheibani NORMS U. S. Nusigar Regulatory Commission i
Mr. S. D. Ebneter, Regional Administrator Mr. D. S. Hood, Licensing Project Manager, NRR Mr. B. R. Bonser, Senior Resident Inspector, Vogtle j
r
'/
b 9307160228 930630 T5 gi i PDR ADOCK 05000424 b
I R
PDR 9
4 4
ENCLOSUIG 1 VOGTLE ELECTRIC GENERATING PLANT. UNIT 1 MONTHLY OPERATING REPORT FOR JUNE 1993 -
TABLE OF CONTENTS NARRATIVE REPORT Page Vl-1 OPERATING DATA REPORT Page V!-2 AVERAGE DAILY POWER LEVEL Page VI-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page VI-4 e
1 1
s..
\\
NARRATIVE REPORT DOCKET NO, 50-424 UNIT 1 DATE:
JULY 1,1993 COMPLETED BY; G. L. HOOPER TELEPHONE:
(706) 826-4104 JUNE 01 00:00 UNIT 1 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.
JUNE 30 23:59 UNIT 1 AT 100% POWER WITH NO OPERATIONAL PROBLEMS.
l 4
f i
t 1
1 l
l l
l V1-1 l
\\
,,.s
4 OPERATING DATA REPORT DOCKET NO. 50-424 DATE:
JULY 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE:
-(706) 826-4104 OPERATING STATUS
- 1. UNIT NNAE:
VEGP UNIT 1
- 2. REPORT PERIOD:
JUNE 1993
- 3. LICENSED THERMAL POWER (MWt):
3565
- 4. NAMEPLATE RATING (GROSS MWe):
1215
- 5. DESIGN ELECTRICAL RATING (NET MWe):
1151
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe):
1212
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe):
1158
- 8. IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
N/A
- 9. POWER LEVEL TO WHICH RESTRICTED,IF ANY (NET MWe):
NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION,IF ANY:
N/A THIS MONTH YR. TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD:
720 4343 53328
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL:
720.0 3272.5 45474.4
- 13. REACTOR RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0 t
- 14. HOURS GENERATOR ON-LINE:
720.0 3182.9 44477.9
- 15. UNIT RESERVE SHUTDOWN HOURS:
0.0
- 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH):
2564437 10792314 148161717-
- 17. GROSS ELEC. ENERGY GENERATED (MWH):
871258 3682313 49663298
- 18. NET ELEC. ENERGY GENERATED (MWH):
835988 3509233 47150198-
.19. REACTOR S RVICE AC OR 100.0 %
75.4 %
85.3%.
E F
T
- 20. REACTOR AVAILABILITY FACTOR 100.0 %
75.4%
- 85.3%
- 21. UNIT SERVICE FACTOR:
100.0%
73.3%
83.4 %
- 22. UNIT AVAILABILITY FACTOR:
100.0 %
73.3 %
83.4 %
- 23. UNIT CAPACITY FACTOR (USING MDC NET):
100.3 %
71.3 %
81.0 %
- 24. UNIT CAPACITY FACTOR (USING DER NET):
100.9 %
71.8 %
80.2%
- 25. UNIT FORCED OUTAGE RATE:
0.0%
2.3%
6.0%
- 26. SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
I NONE
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF STARTUP:
N/A 1
V1-2
UNIT 1 '
AVERAGE DAILY DOCKET NO. 50-424-POWER LEVEL DATE:
JULY 1,1993 4
COMPLETED BY; G. L. HOOPER TELEPHONE:
(706) 826-4104 l
1 DAY Net MW 1
1164
- 2.
1168
- 3.
1161
- 4 1159
- 5.
1155 1163
- 6.
7.
1159
- 8....
1152 9.
1153 10.
1154 11 1157
.i 12.
1160
- 13.
1164
- 14.
1167
- 15.
1165
- 1164
- 16..
17 1165 *
' 18.
1166
- 19...
1168
- 20.
1165
- 21.
1164
- 22.
1162*
23.
1162
- 24.
1160
- 25..
1163
- 26 1157 27.
1160
- 28.
1159
- 29.
1159
- 30.
1161
- e
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-424 DATE:
JULY 1,1993 UNIT NAME:
VEGP UNIT 1 COMPLETED BY: G. L. HOOPER TELEPHONE:
(706) 826-4104 REPORT MONTH JUNE 1993 e
V R
M S
E E
Y T
A T
LICENSEE SC Y
S H
EVENT TO COMPONENT CAUSE & CORRECTIVE P
DURATION 0 0
REPORT ED CODE ACTION TO NO.
DATE E
(HOURS)
N D
NUMBER ME (SUBCODE)
PREVENT RECURRENCE N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A J
a F: FORCED REASON:
METHOD:
EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2 - MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3 - AUTO. SCRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4 - CONTINUATIONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5 - LOAD REDUCTION F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN)
'b h
V1-4
ENCLOSURE 2 VOGTLE ELECTRIC GENERATING PLANT - UNIT 2
- MONTHLY OPERATING REPORT FOR JUNE 1993 TABLE OF CONTENTS NARRATIVE REPORT Page V2-1 OPERATING DATA REPORT Page V2-2 AVERAGE DAILY POWER LEVEL Page V2-3 UNIT SHUTDOWNS AND POWER REDUCTIONS Page V2-4
J
]
4.
NARRATIVE REPORT DOCKET NO. 50-425 UNIT 2 DATE:
JULY 1,1993 1
COMPLETED BY: G. L HOOPER l
TELEPHONE:
(706) 826-4104 i
JUNE 01 00:00 UNIT 2 AT 99% POWER WITH NO OPERATIONAL PROBLEMS.
JUNE 28 04:57 UNIT 2 MANUAL REACTOR TRIP DUE TO MFRV FAILING SHUT. ENTERED MODE 3 JUNE 28 22:23 UNIT 2 ENTERED MODE 2 JUNE 28 23:35 UNIT 2 REACTOR CRITICAL.
I JUNE 29 01:26 UNIT 2 ENTERED MODE 1 JUNE 29 04:15 UNIT 2 TIED TO GRID.
JUNE 30 22:00 UNIT 2 RETURNED TO 99% POWER WITH NO OPERATIONAL PROBLEMS.
'l JUNE 30 23:59 UNIT 2 AT 99% POWER WITH NO OPERATIONAL PROBLEMS.
I 1
i V2-1 l
'i
OPERATING DATA REPORT DOCKET NO. 50-425 DATE:
JULY 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE:
(706) 826-4104 OPERATING S TATUS
- 1. UNIT NAME:
VEGP UNIT 2
- 2. REPORT PERlOD:
JUNE 1993
- 3. LICENSED THERMAL POWER (MWt):
3565
- 4. NAMEPLATE RATING (GROSS MWe):
1215
- 5. DESIGN ELECTRICAL RATING (NET MWe):
1151
- 6. MAXIMUM DEPENDABLE CAPACITY (GROSS MWe):
1211
- 7. MAXIMUM DEPENDABLE CAPACITY (NET MWe):
1157 8, IF CHANGES OCCUR IN CAPACITY RATINGS N/A (ITEMS 3 THROUGH 7) SINCE LAST REPORT, GIVE REASONS:
i
- 9. POWER LEVEL TO WHICH RESTRICTED, IF ANY (NET MWe):
NO RESTRICTIONS
- 10. REASONS FOR RESTRICTION,IF ANY:
N/A THIS MONTH YR. TO DATE CUMULATIVE
- 11. HOURS IN REPORTING PERIOD:
720 4343 36072
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL:
701.4 4324.4 32570.3
- 13. REACTOR RESERVE SHUTDOWN HOURS:
0.0 0.0
. 0.0
- 14. HOURS GENERATOR ON-LINE:
696.7 4319.7 32107.3 '
- 15. UNIT RESERVE SHUTDOWN HOURS:
0.0 0.0 0.0
- 13. GROSS THERMAL ENEPJY GENERATED (MWH):
2406365 14798368 105286716
- 17. GROSS ELEC. ENERGY GENERATED (MWH):
817135 5095701 35680977
- 18. NET ELEC. ENERGY GENERATED (MWH):
778885 4866651 33933227-
- 19. REACTOR SERV!CE FACTOR 97.4 %
99.6 %
90.3 %
- 20. REACTOR AVAILABILITY FACTOR 97.4 %
99.6% -
90.3%
- 21. UNIT SERVICE FACTOR:
96.8%.
99.5 %
89.0%
22: UNIT AVAILABILITY FACTOR:
96.8%
99.5%
89.0% '
- 23. UNIT CAPACITY FACTOR (USING MDC NET):
93.5%
100.1 %
85.2%'
- 24. UNIT CAPACITY FACTOR (USING DER NET):
94.0 %
100.2 %
85.3%
- 26. UNIT FORCED OUTAGE RATE:
3.2%
0.5%
1.7%
26, SHUTDOWNS SCHEDULED OVER THE NEXT 6 MONTHS (TYPE, DATE, AND DURATION OF EACH):
REFUELING, SEPTEMBER 11,1993,37 DAYS
- 27. IF SHUTDOWN AT END OF REPORT PERIOD, ESTlMATED DATE OF STARTUP:
NA V2-2
.g
' UNIT 2 '
AVERAGE DAILY DOCKET NO. 50-425 POWER LEVEL DATE:-
JULY 1,1993 COMPLETED BY; G. L. HOOPER 1
- TELEPHONE:
-(706) 826-4104
.I i
DAY Net MW -
1 1151 2.
1156 1
3, 1148.
4.
1142 5.
1139 6.
1149 7.
1147 8.
1141 9..
1134 10.
1142 11-1145 12.
1146 13.
1150 14.
1152 1150 15.
16.
1147 17, 1147 18,
1149-19.
1147 20.
1150 21
-1149 22.
1143 23.
1145' 24 1143 25...
1146 26.
1147 27.
1144 28.
147 29.
255' 30.
1103
.i s
V2-3 S
s i,
e
UNIT SHUTDOWNS AND POWER REDUCTIONS DOCKET NO. 50-425 DATE:
JULY 1,1993 UNIT NAME:
VEGP UNIT 2 COMPLETED BY: G. L. HOOPER TELEPHONE:
(706) 826-4104 REPORT MONTH JUNE 1993,
R M
S E
E Y
T A
T LICENSEE SC Y
S H
EVENT TO COMPONENT CAUSE & CORRECTIVE P
DURATION O
O REPORT ED CODE ACTION TO NO.
DATE E
(HOURS)
N D
NUMBER ME (SUBCODE)
PREVENT RECURRENCE i
I 6/27 F
23.3 A
2 2-93-004 JB FCV SEE BELOW 93-1 F: FORCED REASON:
METHOD:
EVENTS REPORTED INVOLVE S: SCHEDULED A-EQUIPMENT FAILURE (EXPLAIN) 1 - MANUAL A GREATER THAN 20%
B-MAINTENANCE OR TEST 2 - MANUAL SCRAM REDUCTION IN AVERAGE C-REFUELING 3-AUTO. SCRAM DAILY POWER LEVEL FOR D-REGULATORY RESTRICTION 4 - CONTINUATIONS THE PRECEDING 24 HOURS.
E-OPERATOR TRAINING & LICENSE 5-LOAD REDUCTION F-ADMINISTRATIVE 9 - OTHER (EXPLAIN)
G-OPERATIONAL ERROR (EXPLAIN)
H-OTHER (EXPLAIN)
CAU_SE:
UNIT 2 MANUAL TRIP IN RESPONSE TO DECREASING LEVEL ON STEAM GENERATOR 2. THE DECREASING LEVEL WAS A RESULT OF A FAILURE OF THE #2 MAIN FEED REGULATING VALVE TRACKER / DRIVER CARD.
CORRECRVE ACT!ON; STEAM GENERATOR LEVEL WAS RESTORED. THE FAILED CIRCUlT CARD WAS REPLACED AND WILL UNDERGO FAILURE ANALYSIS.
-I V24
^
+
4 ENCLOSURE 3 VOGTLE ELECTRIC GENERATING PLANT - UNITS 1 AND 2 i
MONTHLY OPERATING REPORT FOR JUNE 1993 CHALLENGES TO PORV OR SAFETY VALVES 1
)
l l
I
(ENCLOSURE 3)
DOCKET NOSi 50-424,50-425 VEGP UNITS 1 & 2 DATE:
JULY 1,1993 COMPLETED BY: G. L. HOOPER TELEPHONE:
(706) 826-4104 t
EVENT DATE TAG NO.
TYPE DESCRIPTION NO EVENTS FOR JUNE
?
i 9
3