U.S. NUCLEAR REGULATORY COMMISSIC"
,
,
REGION III
Reports No. 50-456/93014(DRSS); 50-457/93014(DRSS)
Dockets No. 50-456; 50-457
Licensee:
Commonwealth Edison Company
Opus West III
1400 Opus Place
Downers Grove, IL 60515
Facility Name:
Braidwood Nuclear Station, Units 1 and 2
Inspection At: Braidwood Station
-Type of Inspection: Announced, Routine Physical Security Inspection
Inspection Dates: May 17-21, 1993
Inspector:
Q
k bngt1
[o!7!N3
J. L. Belanger
V
Date
Senior Physical Security Inspector
Approved By:
f gmes R. Creed, Chief
Date
G
Mafeguards Section
1
Inspection Summary
Jnspection on May 17-21. 1993 (Reports No. 50-456/93014(DRSS):
50-457/93014(DRSS))
Areas Insp_ected: Routine, announced physical security inspection involving
'
Management Support, Security Program Plans and Audits; Protected and Vital
Area Physical Barriers, Detection and Assessment Aids; Protected and Vital.
Area Access Control of Personnel, Packages and Vehicles; and Alarm Stations
and Communications.
i
Results: The licensee was found to be in compliance with NRC requirements
within the areas examined except for one violation in the area of access
control of vehicles:
Ino20eure centsina
gAygGUARDS Ilir02fATION
to e
l
9306280031 930609
ADOCK 05000456
G
.
.
.-
-
.
. .
'.
3
..
s
ON
Certain vehicles were assigned to designated vehicle status, yet they.
routinely were assigned outside the protected area which is contrary to
the definition of a designated vehicle. A lack of management oversight
and inadequate procedural guidance characterized the licensee's
designated vehicle program.
.
The licensee's newly upgraded security communications system was identified as
'
a program strength. A weakness in the CCTV assessment of one alarm zone
because of low lighting was identified.
,
,
Four observations were noted.
Recent security force personnel layoffs have had a negative effect on
morale.
The quality of the x-ray machines barely met test standards anri should
.
be closely monitored by management.
The recently assigned onsite Quality Verification auditor responsible
for conducting field monitoring observations does not possess security
experience; consequently, this may affect his ability to identify
problem areas in the security program.
The offsite Quality Verification audit program improved because of the
comprehensive pre-audit checklist developed during the preparation phase
and the security experience of the auditor assigned.
Protected and vital area physical barriers and their associated detection
systems were maintained in an excellent condition. The quality of the-CCTV
assessment system continued to improve through an ongoing program to replace
tube cameras with solid state cameras. Alarm station operations were
excellent because of the knowledge and professionalism of the station
operators, the quality of station equipment, and the maintenance of that
equipment.
Eno30eure Containe
5
ra
Peco In Dooontrolled
.