C GE Nucicar Energy Geew onn own us cw:w Ame se on CA 95U5 June 18, 1993 MFN 098-93 Docket No. STN 52-001 i
Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention:
Mr. Richard W. Borchardt, Acting Director Standardization Project Directorate
Subject:
Submittal Supporting Accelerated ABWR Design Certification Review -
Submittal of Fourth Phase of Revised ABWR Tier-1/ITAAC Material i
Dear Mr.'Borchardt:
Enclosed are thirty-four (34) revised versions of ABWR' Tier 1/ITAAC material for fourteen (14) ABWR systems. The attached table lists these systems and the other ABWR Tier 1 material covered by this submittal. 'This material' represents the fourth and last of the ABWR Tier 1/ITAAC submittals we have scheduled. This transmittal, together with those of April 26, May 21, and June 4, 1993, provides material for a total of 79 ABWR systems.
1 The updated Tier 1 material'in this and the other submittals noted above s
have been prepared in parallel.with closure of open items on the SSAR and may not reflect very recent CE/NRC agreements on SSAR'open issues.
For example, some of the systems in either this and earlier transmittals may not fully reflect the outcome of GE/NRO discussions on probabilistic risk as-sessment (PRA) and severe accident insights. However, we do not view this parallel SAR resolution / Tier 1 submittal process as causing major difficulties and plan to update the Tier 1 systems material in the next few weeks to incorporate resolved SSAR design issues. We anticipate this will result in some revisions being sent to you between now and early July, 1993.
We plan to submit these revisions as hand written markups of theLearlier material. We do not anticipate any major perturbations and do not bell' eve this change process should impede staff review of the ABWR Tier 1 document.
3 240004-go
- gg62;B93ZiByggi j i$
A k
j
f i
Document Control Desk June 18, 1993 U. S. Nuclear Regulatory Commission MFN 098-93 Washington, D. C.
Docket No. STN 52-001 Attn:
Mr. Richard V. Borchardt The attached material includes road map tables for PRA Analyses and Three Mile Island issues.
These entries complete our set of road maps with the exception of a road map addressing USI/GSI resolution. This subject is -
still being addressed at the SSAR level; a Tier 1 road map will be prepared l
when the SSAR work is complete.
In addition, we are still updating the l
Control Building arrangement drawings to reflect recent GE/NRC agreements on design changes. These figures will be av ailable in the very near future, and a completed entry 2.15.12 together vith an updated version of 3.2 Radiation Protection will be submitted as soon as possible.
j l
The material in this and the other phased submittals (4/26/93, 5/21/93 and 6/4/93) is preliminary in that it has not been fully verified using GE j
procedures governing compliance with quality assurance requirements for j
engineering documentation.
This activity will involve verifying Tier 1 material against the final version of the SSAR and is scheduled to be i
completed in August 1993. Our current plan is to resubmit the complete set of verified ABWR Tier 1 material at the end of August 1993.
j As always, GE personnel will be happy to provide any support the NRC staff review teams feel they need to complete their review of the-attached material.
Sincerely, i
David J. Robare, Acting Manager Safety and Licensing (408) 925-6948 enclosures cc:
T. A. Boyce (NRC)
N. D. Fletcher (DOE)
C. Poslusny (NRC)
A. J. James (GE)
R. Louison (GE)
N. D. Hackford (GE)
J. F. Quirk (GE)
J. N. Fox (GE)
J. A. Beard (GE-Rockville) AJJ6-4:e
- f t
p ABWR DESIGN CERTIFICATION TIER 1 - PHASE D SUBMITTAL 6/18/93 l
CONTENTS System Material l
l Item 2.8.1 Nuclear Fuel 2.8.2 Fuel Channel i
2.8.3 Control Rod 2.9.1 Radwaste 2.9.2 Floor Drain Collection System
[
2.11.1 Makeup Water- (Purified) System -
i 2.11.2 Makeup Water (Condensate) System i
2.11.5 HVAC Normal Cooling Water System
't 2.11.6 HVAC Emergency Cooling Water System-7 2.14.1 Primary Containment System 2.14.9 Suppression Pool Temperature Monitoring System.
2.15.5a Control Building HVAC Systems.
l 2.15.5b Control Room Habitability Area HVAC System 2.15.5c Reactor Building HVAC System
.i h
Other Material Appendix B: Abbreviations and Acronyms' Revised Table of Contents _
2.7.1 Main Control Room Panels - Table 2.7.la (Design Description-submitted 6/4/93)
~
Road Maps for PRA Analysis and TMI Issues (Tables'11 and'13)
Interface Reauirements i
4.3 Potable and Sanitary Water i
4.6 Makeup Water Preparation 4.8 Airborne Particulate Radiation Monitoring
)
4.9 Heating, Ventilating and Air Conditioning TO BE SUBMITTED LATER 2.15.12 Control Building Figures (Design Description submitted 5/21/93)-
3.2 Radiation Protection AJJ6-4:e
]
l
b s
GE Nuclear Energy O
General Electnc Company 175 Curtnet A enue. San Jose. CA 951251014 i
)
June 18, 1993 MFN 098-93 Docket No.-STN 52-001 Document Control Desk U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Attention:
Mr. Richard W. Borchardt, Acting Director Standardization Project Directorate Subj ect:
Submittal Supporting Accelerated ABWR Design Certification Review -
Submittal of Fourth Phase of Revised ABWR Tier 1/ITAAC Material
Dear Mr. Borchardt:
Enclosed are thirty-four (34) revised versions of ABWR Tier 1/ITAAC material for fourteen (14) ABWR systems. The attached table lists these systems and the other ABWR Tier 1 material covered by this submittal.. This material-represents the fourth and last of the ABWR Tier 1/ITAAC submittals we have scheduled. This transmittal, together with those of April 26, May 21, and' June 4,1993, provides material for a total of 79 ABWR systems.
The updated Tier 1 material in this and the other submittals noted above l
have been prepared in parallel with closure of open items on the SSAR and may not reflect very recent CE/NRC agreements on SSAR open issues. For-example, some of the systems in either this and earlier transmittals may not fully reflect the outcome of CE/NRC discussions on probabilistic risk as-I sessment (PRA) and severe accident insights. 'However, we do not view this parallel SAR resolution / Tier 1 submittal process as causing major difficulties and plan to update the Tier 1 systems material in the next few weeks to incorporate resolved SSAR design issues. We anticipate this will result in some revisions being sent to you between now and early July,1993.
We plan to submit these revisions as hand-written markups of the earlier material. We do not anticipate any major perturbations and do not believe this change process should impede staff review of the ABWR Tier 1 document.
OU
4 O
Document Control Desk June 18, 1993 U. S. Nuclear Regulatory Commission MFN 098-93 Washington, D. C.
Docket No. STN 52-001 Attn:
Mr. Richard W. Borchardt The attached material includes road map tables for PRA Analyses and Three Mile Island issues. These entries complete our set of road maps with the exception of a road map addressing USI/GSI resolution. This subject is still being addressed at the SSAR level; a Tier 1 road map will be prepared when the SSAR work is complete.
In addition, we are still updating the Control Building arrangement drawings to reflect recent GE/NRC agreements on design changes. These figures will be available in the very near future, and a completed entry 2.15.12 together with an updated version of 3.2 Radiation Protection will be submitted as soon as possible.
The material in this and the other phased submittals (4/26/93, 5/21/93 and 6/4/93) is preliminary in that it has not been fully verified using GE procedures governing compliance with quality assurance requirements for engineering documentation. This activity will involve verifying Tier 1 material against the final version of the SSAR and is scheduled to be completed in August 1993. Our current plan is to resubmit the complete set of verified ABWR Tier 1 material at the end of August 1993.
As always, GE personnel will be happy to provide any support the NRC staff review teams feel they need to complete their review of the attached material.
Sincerely, David J. Robare, Acting Manager Safety and Licensing (408) 925-6948 enclosures cc:
T. A. Boyce (NRC)
N. D. Fletcher (DOE)
C. Poslusny (NRC)
A. J. James (GE)
R. Louison (GE)
N. D. Hackford (GE)
J. F. Quirk (CE)
J. N. Fox (GE)
J. A. Beard (GE-Rockville)
O Y i AJJ6-4:c i
ABWR DESIGN CERTIFICATION-TIER PHASE D SUBMITTAL 6/18/93 CONTENTS l
System Material Item 2.8.1 Nuclear Fuel l.
2.8.2 Fuel Channel 2.8.3 Control Rod 2.9.1 Radwaste l
2.9.2 Floor Drain _ Collection System 2.11.1 Makeup Water (Purified) System l
2.11.2 Makeup Water (Condensate) System l
2.11.5 HVAC Normal Cooling Water System l
2.11.6 HVAC Emergency Cooling _ Water. System j
2.14.1 Primary Containment System 2.14.9 Suppression Pool Temperature l
Monitoring System l
2.15.5a Control' Building HVAC Systems l
2.15.5b Control Room Habitability I
Area HVAC System 2.15.5c Reactor: Building HVAC System
- O Other Material
. Appendix B: Abbreviations and Acronyms Revised Table of Contents 2.7.1 Main Control Room Panels.- Table 2.7.la'(Design Description submitted 6/4/93)
Road Maps for PRA Analysis and TMI Issues (Tables 11 and 13)
Interface Reauirements 4.3 Potable and Sanitary Water 4.6 Makeup Water Preparation 4.8 Airborne Particulate Radiation Monitoring 49 Heating, Ventilating and Air Conditioning i
TO BE SUBMITTED IATER 2.15.12' Control Building _ Figures-(Design Description' submitted'5/21/93)'
'3.2-Radiation Protection AJJ6-4:c