Text
- --
a.
June 14, 1993 Docket No'. 50-395 J
- I d
Mr. John L. Skolds.
Vice President, Nuclear Operations South Carolina Electric & Gas' Company Virgil C. Summer Nuclear Station Post Office-Box 88 Jenkinsville, South Carolina 29065
.j
~!
Dear Mr. Skolds:
1
SUBJECT:
RELIEF REQUEST FOR APPROVAL TO PERFORM OUTLET N0ZZLE INSPECTIONS' DURING PERIOD THREE OF THE FIRST TEN-YEAR INTERVAL -
VIRGIL C. SUMMER NUCLEAR STATION, UNIT NO. 1 (TAC NO. M85660)-
By letter November 30, 1992, and supplemented by letter dated dated January. 29, 1993, South Carolina Electric & Gas Company submitted a request to perform the outlet nozzle safe end inspection, scheduled for the first period of the;;
j second ten-year inspection interval, eight months: ahead of schedule.
South j
Carolina Electric & Gas Company further proposed that 100 percent of the" j
nozzle-to-vessel welds be inspected in the third period of the second ten-year-inspection interval and subsequent inspection intervals.
i The staff has reviewed your request and has determined that the proposed -
alternative is acceptable. The staff finds that the proposed alternative will provide an acceptable level of quality and safety, and authorizes its use y
pursuant to 10 CFR 50.55a(a)(3)(1). An evaluation of the request is enclosed.
1 i
Sincerely, J
ORIGINAL SIGNED BY:
l S. Singh Bajwa, Acting Project Director Project Directorate 11-1 Division ~of Reactor Projects - I/II i
Enclosure:
Office of Nuclear Reactor Regulation.
As stated J
cc w/ enclosure:
.l See next page q
l DISTRIBUTION:
Docket Filee P. Anderson NRC/ Local PDRs G. Wunder PD 11-1 Reading File OGC T. Murley/F. Miraglia 12-G-18 E. Jordan MNBB 3701 J. Partlow G-18 G. Hill (2).P1 37 E. Rossi 9-A-2 ACRS (10)
J. Lieberman 7-H-5 OP.*4 S. Varga OC/LFDCB G. Lainaf 9306180272 930614 L. Plisco, ED0 17-G-21 S. Bajwa PDR ADOCK 05000395 E. Merschoff, R-II' P
PDR.
P1 ant Service list
.{
cc:
s:
y,g_,
- See previous concurrence LA'PD2hhhE PM:PD23;L[PE AD:PD21:DRPE, OGC*
I O
0FC HAME PDAn h GF M r:tmw SSBajwa hb ATH for JHull k
DATE
.06/IN/93 06//// ' /93' 06/ llf /93 06/09/93 h"
Document Name: SUM 85066.LTR
=
Mr. John L. Skolds Virgil C. Summer Nuclear Station South Carolina Electric & Gas Company cc:
Mr. R. J. White Nuclear Coordinator S.C. Public Service Authority l
c/o Virgil C. Summer Nuclear Station Post Office Box 88, Hail Code 802 Jenkinsville, South Carolina 29065 J. B. Knotts, Jr., Esquire l
Winston & Strawn Law Firm 1400 L Street, N.W.
Washington, D. C.
20005-3502 Resident Inspector / Summer NPS c/o U.S. Nuclear Regulatory Commission Route 1, Box 64 Jenkinsville, South Carolina 29065 Regional Administrator, Region II U.S. Nuclear Regulatory Commission 101 Marietta St., N.W., Ste. 2900 Atlanta, Georgia 30323 Chairman, Fairfield County Council Drawer 60 Winnsboro, South Carolina 29180 Mr. Heyward G. Shealy, Chief Bureau of Radiological Health l
South Carolina Department of Health and Environmental Control 2600 Bull Street l
Columbia, South Carolina 29201 1
Mr. R. M. Fowlkes, Manager Nuclear Licensing & Operating Experience South Carolina Electric & Gas Company Virgil C. Summer Nuclear Station Post Office Box 88 Jenkinsville, South Carolina 29065 1
+
_ _.. _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ _ _