- e. 4 No. 93-68 EA No.93-138 U. S. NUCLEAR REGULATORY COMMISSION REGION I NOTICE OF SIGNIFICANT LICENSEE MEETING Licensee:
Ieng Island Lighting Company Facility:
Shoreham Nuclear Power Station Docket No.:
50-322 Time and Date:
10:00 a.m., June 9,1993 location:
DRSS Conference Room, U. S. NRC Region I, King of Prussia, PA
Purpose:
Enforcement Conference on Fall of Refueling Jib Crane (EA No.93-138)
NRC Attendees:
R. W. Cooper, II, Director, Division of Radiation Safety and Safeguards (DRSS)
W. Hodges, Director, Division of Reactor Safety (DRS)
E. Imbro, Acting Deputy Director, DRS J. H. Joyner, Chief, Facilities Radiological Safety and Safeguards Branch, DRSS E. Wenzinger, Chief, Reactor Projects Branch No. 2, Division of Reactor Projects (DRP)
C. Anderson, Chief, Reactor Projects Section 2B, DRP W. J. Pasciak, Chief, Facilities Radiation Protection Section, FRS&SB, DRSS R. Nimitz, Senior Radiation Specialist, FRPS, FRS&SB, DRSS C. Pittiglio, Project Manager, NMSS/LLDR J. Carrasco, Reactor Engineer, DRS D. Holody, Enforcement Officer M. Banerjee, Senior Enforcement Specialist K. Smith, Regional Attorney Licensee Attendees:
L. M. Hill, Resident Manager R. L. Patch, Nuclear Quality Assumnce Department Manager S. Schoenwiesner, Licensing Regulatory Compliance Department Manager vi0006 gppgg,geconDCOPY p
9306080071 930527 PDR ADOCK 05000322
/
P pga i
- s.
Ung Island Lighting Company 2
Note: This meeting is closed to the public. Handicapped persons requiring assistance to attend the meeting shall make their requests known to Walter J. Pasciak, Chief, Facilities Radiation Protection Section, U. S. Nuclear Regulatory Commission, Region I,475 Allendale Road, King of Prussia, PA, 19406, (215) 337-5258, no later than five business days prior to the meeting. Attendance by NRC personnel at this i
meeting should be made known by 4:00 p.m., June 7,1993.
Original signed By:
Prepared By:
Walter J. Pasciak, Chief Facilities Radiation Protection Section b
i OFFICIAL RECORD COPY
1 v.
t Long Island Lighting Company 3
Distribution: (Via FeMall)
J. M. Taylor, Executive Director for Operations (EDO)
J. Sniezek, Deputy Executive Director for Nuclear Reactor Regulation, Regional Operations and Research (DEDR)
T. E. Murley, Director, Office of Nuclear Reactor Regulation H. Thompson, Deputy Executive Director for Nuclear Material Safety, Safeguards and Operations Support (DEDS)
J. Lieberman, Director, Office of Enforcement B. Grimes, Director, Division of Operating Reactor Support, NRR q
J. Partlow, Associate Director for Projects, NRR j
V. McCree, Regional Coordinator, OEDO S. Lewis, Office of the General Counsel (OGC)
R. Bernero, Director, Office of Nuclear Material Safety and Safeguards R. Bangart, Director, Division of Low-Level Waste Management and Decommissioning i
S. H. Weiss, Director, Non-Power Reactors and Decommissioning Project Dictorate J. Austin, Chief, Decommissioning and Regulatory Issues Branch, NMSS L. Bell, Chief, Facilities Section, Decommissioning and Regulatory Issues Branch C. Pittiglio, Project Manager, Facilities Section, Decommissioning and Regulatory Issues Branch Region I Branch Chiefs Region I Section Chiefs K. Abraham, Public Affairs Officer, RI D. Screnci, Field Public Affairs Officer, RI M. Miller, State Liaison Officer, RI T. Darden, State Agreements Officer, RI K. Smith, Regional Attorney, RI D. Holody, Enforcement Officer, RI B. Iztts, Office of Investigations, Region I Field Office J. Lanning, DRP, RI P. Jefferson, DRMA, RI 1
OFFICIAL RECORD COPY
4 ay a i
Long Island Lighting Company 4
Distribution:
Pablic Document Room (PDR)
Local Public Document Room (LPDR)
Leslie Hill, LIPA State of New York RA Secretary, RI DRP Division Secretary, RI DRS Division Secretary, RI DRSS Division Secretary, RI DRMA Division Secretary, RI Projects Branch No. 2, Secretary, RI Region I Receptionist i
6
'J h
?
2
+
i D
t i
i
?
I i
i i
OFFICIAL RECORD COPY l
f
~
Ieng Island Lighting Company 5
i
?
i 1
L i
i RI:DRSS S
RI:DRSS (lLb Jty-Nimitzlslj P
ak Joyner 527/93 5
3 5A793 OFFICIAL RECORD COPY
---