4 7------------------------------------------m-m-mmmmm 6
1
- wnc pons sig U.S. NUCLEAR REIULATORY COMMISSION CERTIFICATE OF COMPLIANCE 1
- =
l secrRr' FOR RADIOACTIVE MATERIALS PACKAGES
,1 1l I
, a coatw, care NuMacR o newsica.NuMesa cfACKAC.E IDE.NMiCAlioN NUMBER d PAGE NUMBER e roTAt NUMBER PAGES g
9178 6
TEA /917A /a 1
m
!I il t pat *Mste a This certificate is issued to certif y that the packagmg and contents descr. bed in item 5 below, meets the apphcable safety standards set forth m Title 10, Code ll of redermi neguistions. eart ri. eackagmg and Transportation of nadioaci-e unter ai-1.,
3 b Tnis certif.cate does not reheve the consignor from comphance with any reQusrement of the regulations of the U S. Department of Transportation or other f
I R
apphcabie reguistory agencies. includmg the government of any country tnrough or into which the package wiii de transported.
ji 4
jl g
l i
(
'I g
i rnis,,gri,ric,a1ys issutoy rse aAsis or a s**rTv Natvsis,ntgonT,or 1,st,rga,c,sys4aN 04apeyt,rg y
I
- I l
'l i
Pacific Nuclear Systems, Inc.
NUPAC application dated February 29, 1988, ll l
Brookside Office Park as supplemented.
'I I
One Harbison Way, Suite 209 ill I
Columbia, SC 29212 i
I I
- c. DOCKET NUMBER 7),qj7g E
- a. coNortioNs I
This certificate is condmonal upon fumlhng the reQuarements of 10 CFR Part 71, as apphcable, and the condations specified below j!
l lI L
s.
- I
(
- I l
(a)
Packaging i
(1)
Model Nos.: NUPAC 7/100 and LN 7-100 (1'
I lI t
l I
(2)
Description
- I I
il ll I
Steel encased lead shielded casks for low specific activity material. The l
casks are right circular cylinders.with a 75.5-inch ID by 40.75-inch IH l
cavity.
The walls of the' casks contain a lead _ thickness of 3.00 inches lll I
l encased in 0.38-inch thick inner steel shell and 0.88-inch thick outer steel ll I
shell. The' top cover and cask bottom are made up of two steel plates ranging 1 :
y I
in thickness from 2.0 to 3.5 inches. The primary. cask lid is secured to the ll L
cylindrical' cask body by eight, 1-1/4-inch rachet' binders. An optional ll l
secondary lid-is centered in the primary lid and is secured to the primary g
i lid with eight,,3/4-inch studs and nuts.
Each lid is provided with a l
7 i
Neoprene gasket seal. The casks may be,provided with an optional 12-gauge it. ;
I stainless steel liner (seal. welded alongLall edges), an optional lid vent jl il I
line with pipe plug, and an optionalL3/4-inch drain line and pipe plug. The I
casks are provided with four equally spaced lifting / tie-down devices. The lp I
primary lid is provided with three lifting lugs and the optional secondary i
g lid is provided with one lifting lug.
Each cask has a gross weight of 48,900 lg I
g pounds.
jl 1
I 1-ll l
ll 1
l'I i
I l
I jl I
>l I
!I l
l
!I l
!I l
ll
\\
l il I
il I
il l
lI l
I i
I il I
9305260357 930520
{DR ADOCK 0720 8
m q------------------------------
CONolTicNS (continued) i V
I P
l 'Page 2 - Certificate No. 9178 - Revision No. 6 - Docket No. 71-9178 h
I h
l P
q 5.
(b)
Drawings F
W F
I Model No. NUPAC 7/100 E
F l
The package is fabricated in accordance with Nuclear Packaging, Inc.,
g Drawing No. X-20-309-SNP, Sheets 1, 2, and 3, Revision No. A.
g F
3, 1
Model No. LN 7-100 4
g k
N The package is fabricated in accordance with LN Technologies Corporation l
Drawing No. 5025-M-2005, Sheets 1 and 2, Revision No. O.
g (c)
Contents F
f h
g j
I (1) Type and form.of material O
N l
(i)
Dewatered, solid, or solidified wastest meeting the requirements h
y for low specific activity material, in secondary containers; or p
U l
I (ii)
Activated: solid components meeting the requirements for low F
l specific activity material, fin (secondary c6ntainers.
[
l cyz m
l (2) Maximum quantity ofimaterial per pack'agi '
L
.. i 3x 2
- .:y t
i Greater than. Type A" quantity.of radio'ctive material 4hich may contain a
=
i fissile material providedithe ? fissile material doesinot exceed the limits I
of 10 CFR 671.53.
The decay; heat; load is. limited to:17 watts.
~
I
.7, c
..r s
6.
(a)
Foranypackagecontaihingwatertand/or;organicsubstinceswhichcould l
i g
radiolytically generate ' combustible gases, _ determination must be made by 7
g tests and measurements or by' analysis;of'a~ representative package such that I
i the following criteria are met'over!a period of time that is twice the f
I expected shipment-time:
A,'
[
I i:
i l
(i) The hydrogen' generated must be limi.ted to a molar quantity that would be b
4 no more than 5% by volumeL(or; equivalent limits for other inflammable f
gli gases)ofthesecondarycoptainergasvoidifpresentatSTP(i.e.,no f
l more than 0.063 g-moles /ft at 14.7 psia and 70*F); or
[i 11 1
(ii) The secondary container and cask cavity must be inerted with a diluent to L
l assure that oxygen is limited to 5% by volume in those portions of the p
y package which could have hydrogen greater than 5%.
[
i E
I For any package delivered to a carrier for transport, the secondary container f, I
must be prepared for shipment in the same manner in which determination for h
I gas generation is made.
Shipment period begins when the package is prepared i
l (sealed) and must be completed within twice the expected shipment time.
a I
W I
Ril J
I Ii 1
,------------------------------------y------:
(f""
conosinons tcontinued)
N I
E la I
Page 3 - Certificate No. 9178 - Revision No. 6 - Docket No. 71-9178
!N E
p i
i I
!n g
(
(b)
For any package shipped within 10 days of preparation, or within 10 days 1
i after venting of drums or other secondary containers, the determination in ll; 1
(a) above need not be made, and the time restriction in (a) above does not I
l apply.
j E
!g g
7.
Maximum gross weight of the contents, secondary containers, and shoring is limited jy g
to 13,000 pounds.
g R
ll I
8.
Except for close fitting contents, shoring must be placed between secondary I
I containers and the cask cavity to minimize movement during normal conditions of
!I ll transport.
MlI
~
'l q
9.
The lid and the shield plug lifting lugs must not be used for lifting the cask, and i
must be covered in transit,
!g i
5
!s m
4 lI N
- 10. The cask must be provide'd with either (or both) a drain line or a lid vent line as I
l shown in the drawing in order to provide a method to leak' test the package.
)
8
'l i
11.
In addition to the requirements of Subpart G of 10;CFR Part.71:
R
!g l\\
l (a)
Prior to each shipment, the packaging Neoprene lid sealslif opened (or if Il security seal is broken), must be inspected'. :The seals must be replaced with i
l new seals if inspection shows any defects or every twelve ~ (12) months, which j
g ever occurs first. Cavity drain and vent" lines must be sealed with i
g appropriate sealant appl _ied'to the pipelplug threads.
ll; El ji I
(b)
Each packaging must meet the" Accept'ance Tests and Maintenance Program of:
il N
~
~
- )I l
Model No NUPAC 7/100 i
!I g
Section 8.0 of the application.
~
!g R
1 4
Model No. LN 7-100
- I!
(
!Il j)u l
LN Technologies Corporation Procedures WM-036, Rev. A; WM-026, Rev. B; and g
WM-013, Rev. F.
t il i
E' (c)
The package shall be prepared for shipment and operated in accordance with
,1 l l
the Operating Procedures of:
[
l Model No. NUPAC 7/100
)
i ll l
Section 7.0 of the application.
ll I
i i
l Model No. LN 7-100 lI i
g LN Technologies Corporation Procedures WM-025, Rev. C.
l ill 1
i
- 12. The ratchet binders on the cask lid must be torqued to 100110 ft-lbs.
l l
,1 l
13.
The cask body and each cask lid must be marked in accordance with 10 CFR 971.85(c).
a r
d l
il g
I..____________---.....-
....--..I
r
=
l R conomons (continuec)
O*
I I
I l
Page 4 - Certificate No. 9178 - Revision No. 6 - Docket No. 71-9178 f-I i
e l
- 14. The packages authorized by this certificate must be transported on a motor vehicle, P
I railroad car, aircraft, inland watercraft, or hold or deck of a seagoing vessel
[
I assigned for the sole use of the licensee.
L I
h u
E
- 15. The packages authorized by this certificate are hereby approved for use under the
!h y
general license provisions of 10 CFR s71.12.
y n
1 16.
Expiration date: May 31, 1998.
IJ l
r 1
ll j
REFERENCES
)
NuclearPackaging,Inc., application'dat'edFEbruAry:~29,j1988.
b 9
1 h;
i 1
and February 16,1995.Y f>
l Supplements dated: April 19', 1988; p
j NUS supplement dated:
Novbmber 22, 1985.
f b
.,i.,.
s 3
j LN Technologies Corporation supplement dated:
Februarpl6,1988.&
[
j n
{ScientificEcologyGroup,Inc.,supplementdated:/p(ik30,1993i?
l t 47 8
(
I FOR THE ULS". NUCLEAR REGULATORY COMMISSION b
.~
I thar~1es 'E. MacDonald, Chief i
I
)
' ' ' '. Transpoftation Branch >
J a
'Divisientof; Industrial arid h
3 Medical. Nuclear Safety, NMSS L
J lMY 2 01993 N
lf i
1 Date:
'3 1
3 g
i 1
l --
a x
1 y
-j t
l h
I: - l I
1 i
e 1
[
l L
Jl:
1 1
1 e
i L
1 L
1 N
1 L
1 i:
1 F
1 y
1 i:
1 I
p:
w
t
~
t e tro ugl*,
/
i
~,
y UNITED STATES n
E NUCLEAR REGULATORY COMMISSION o
WASHINGTON. D.C. 20066 APPROVAL RECORD Model Nos. NUPAC 7/100 and LN 7-100 Certificate of Compliance No. 9178-Revision 6
.1 I
By application dated February 16, 1993, Pacific Nuclear Systems, Inc. (PNSI),
requested renewal of Certificate of Compliance No. 9178 for the Model No.
j NUPAC 7/100 package. Also, by application dated April 30, 1993, Scientific Ecology Group, Inc. (SEG), requested renewal of Certificate of Compliance No.
j 9178, for the Model No. LN 7-100 package. PNSI or SEG did not make or request i
any changes to the package designs.
j PNSI, the certificate holder, requested that the certificate be revised to.
incorporate their company name and address. The certificate has been revised l
accordingly.
The staff has reviewed previous submittals, including the operating l
procedures, acceptance tests and maintenance programs, and has found them to be complete and adequate.
i The Certificate of Compliance has been renewed for a five year period which expires May 31, 1998.
r
- =
Charles E. MacDonald, Chief Transportation Branch i
J Division of Industrial and 1
Medical Nuclear Safety, NMSS i
NAY 2 01993 Date-i l
l i
)
1 I
--