a s am smums mm mmm m m mm m mm mm mm mm mm.m mmm mm MA i,A-*

MS u.s. NUCLEAR REGULATORY COMMitSION une ronu eis f

ca CERTIFICATE OF COMPLIANCE i

sa cra 71 FOR RADIOACTIVE MATERIALS PACKAGES if a emot wvuota. Tovat wuusta eac

,, ctny,,, cart uvueca i,atveionuvusta s eacnaat notwra scation wuusta h

9177 6

USA /9177/A 1

A a

2 PFttauBL(

p-a This certificate is situed to certify that the ptekaging and contents described m item $ below, meets the appbcable Atet y standards set fortn m Title 10, Code of Federal Regulations. Part 71. *Packagmg and Transportation of Radioactive Materiat

  • b Inis cers,s.c ie das not rei.e ine cons.gnor trom compnance witn any reauerement of Ine reguist.ons of tne u s Department of Transportation or other L

appncat9e reguiaiory agencies. metudmo tne covernment of any country enrouan or into *n.cn the package -m be transported lI t

'l 1

3 r 4g.. cays msuro on wt nass or a sarrTv awatvsm,anga7 c4Tgrgg,ogogg,,,,

[

lf

[

1 l

j Pacific Nuclear Systems, Inc.

NUPAC application dated February 29, 1988, l[

t Brookside Office Park as supplemented.

J f

One Harbison Way, Suite 209

l l

J Columbia, SC 29212 I

l e oocwrt wvusta 71., q 3 7 7 I

I

[i a cowomows l

Twis certit,cate is conditionar upon to tui.ag the reau.rements of io cr A part 71. as appucsoie. and tne conostions specit.ed teiow.

r

(

,[

jL

(

s.

(

l 1

(a) Packaging h

r J

(1)

Model Nos.: NUPAC 10/140 and LN 10-135A l[I l

g l[

[

[

l (2)

Description I

il i{[

1 Steel encased < lead shielded casks for low specific activity material.

The l

casks a're right-circular ~ cylinders with a 66.0-inch ID by 73.0-inch IH l

cavity.

The walls of the' casks contain a lead.. thickness of 2.75 inches

![

i encased in 0.50-inch thickcinneristeel shell and 1.13-inch thick outer steel ll i

i shell.

The top cover and casktbottom are made up of two steel plates ranging jf 1

in thickness.from 2.0 to 3.0 inches. The; primary cask lid is secured to the il I

cylindrical. cask body by eight, 1-1/4-inch rachet; binders. An optional f

j secondary lid is centered in the primary lid and is secured to the primary l

(4(

lid with eight,g 3/4-inch studs and nuts.

Each lid is provided with a i

Neoprene gasket seal. :The casks may be provided with an optional 12-gauge t

i{l I

stainless steel liner (seal welded along.~all edges), an optional lid vent I

line with pipe plug, and an'_cptional 3/4-inch drain line and pipe plug.

The I

casks are provided with four equally spaced lifting / tie-down devices.

The

(

l primary lid is provided with three lifting lugs and the optional secondary

![

lf lid is provided with one lifting lug.

Each cask has a gross weight of 56,500

[

j j

pounds.

li-I l

J i

L I

it

\\

1 if i

l

(

l 3

j[t-(

1 l

d l

J 1

J J

j l[

4[.

!I 1

9305260338 930520

.l PDR ADDCK 07209177

-. _J i

c ppg r,-

w raw-------------====---====-

4 1

amga -

m---------------------

.n f

.s.

ss (cont,nve u.s. NUCMAR REGULATORY ColetelSSION l

i li I

I Page 2 - Certificate No. 9177 - Revision No. 6 - Docket No. 71-9177 i,

I

!g I

I j!g g

5. (a)(3) Drawings R

I Model No. NVPAC 10/140 j

l Q

l The package is fabricated in accordance with Nuclear Packaging, Inc.,

flI y

Drawing No. X-20-308-SNP, Sheets 1, 2, and 3, Rev. A.

l N

i R

Model No. LN 10-135A il i

I The package is fabricated in accordance with LN Technologies Corporation ll l

Drawing No. 5025-M-2005:

Sheets 1 and 2, Rev. O.

H Ij g

(b) Contents

(

i j

i (1) Type and form of material

!g R

llg l

(i) Dewatered,. solid, or solidified waste, meeting-the requirements for low g

specific activity material, in secondary containers; or j

N

!j I

(ii) Activated solid. components meeting the reqsirements for low g

i specific activity material, in_ secondary containers:,

j i

J

~

j l

(2) Maximum quantity of material per package _

~y I

I V

I g

4 l

4 s

Greater than Type A quantity-of radioactjve material which may contain in l

fissile material provided the~ fissile material' does not exceed the limits in y

l

~

The decay heat load is: limited to;24 watts.

i 10 CFR 671.53.

i 4

g Foranypackagecontainingwat' rand /orforganicsub'stakeswhichcould

I I
6. (a) e l

y radiolytically generate combustible gases, determination must be made by j

!l g

tests and measurements or' by: analysis of'a' representat'ive package such that l

N the following criteria are met overJa' period of time that is twice the ly 4

expected shipment time:

g l

E z

il I

l (i) The hydrogen generated must be limi_ted.to a molar quantity that would be i

no more than 5% by volume;(or-equivalent limits for other inflammable jl gases) of the secondary container gas void if present at STP (i.e., no 1,

more than 0.063 g-moles /ft at 14.7 psia and 70*F); or lg lI (ii) The secondary container and cask cavity must be inerted with a diluent to I

1 assure that oxygen must be limited to 5% by volume in those portions of 1

the package which could have hydrogen greater than 5%.

j lu I

For any package delivered to a carrier for transport, the secondary container l

l I

must be prepared for shipment in the same manner in which determination for l'I l

gas generation is made. Shipment period begins when the package is prepared fl g

(sealed) and must be completed within twice the expected shipment time.

l 1

l I

(b)

For any package shipped within 10 days of preparation, or within 10 days j

i I

after venting of drums or other secondary containers, the determination in ln E

(a) above need not be made, and the time restriction in (a) above does not I

l apply.

I, i

I I

_ - - - - - - - - - - - _ _ _ m _ _ _ _ _ _ _ _ _ _ _ _. -.

- _ _ _,I

m---mzururawmmst m w e r s w.r CONotT80NS (contmusd)

N

'I W

I W

Page 3 - Certificate No. 9177 - Revision No. 6 - Docket No. 71-9177

!I 4

I N

'I R

l g

7.

Maximum gross weight of the contents, secondary containers, and shoring is limited lp g

i to 15,000 pounds.

R lI N

8.

Except for close fitting contents, shoring must be placed between secondary il l

containers and the cask cavity to minimize movement during normal conditions of j

q transport.

1 The lid and the shield plug lifting lugs must not be used for lifting the cask, and l1 E'

9.

l E

must be covered in transit.

,I I

I j
10. The cask must be provided with either (or both) a drain line or a lid vent line as lj shown in the drawing in order to provide a method to leak test the package.

g 11.

In addition to the requirements of Subpart G of 10 CFR Part 71:

ll

I

(

i (a)

Prior to each shipment, the packaging Neoprene ' lid seals if opened (or if il f

security seal.is broken), must be inspected. The'sealsmustbereplacedwithj y

new seals if inspection shows any defects or every twelve (12) months, which y

ever occurs first.

Cavity drain and vent lines must be sealed with ll; 1;

appropriate' sealant applied to the pipe plug 1 threads.

lllI 1

1 (b)

Each packaging must meet the Acceptance, Tests and Maintenance Program of:

lI 1

l i

l Model No. NUPAC 10/140

)

1

!I Section 8.0 of the application.

ji 1

~

il d

Model No.-LN 10-135A J'

!I r

,1 y

<g g

LN Technologies Corporation Procedures WM-036, Rev. A; WM-026, Rev. B; and lg y

WM-013, Rev. F.

l 1

.I 1

(c)

The package shall be prepared for shipment and/ operated in accordance with

I j

the Operating Procedures of:

j[l

$gj Model No. NVPAC 10/140 g

4 il M'

Section 7.0 of the application.

ll 1

,1 i

'j Model No. LN 10-135A g

LN Technologies Corporation Procedures WM-025, Rev. C.

lli r

1 I

l

12. The ratchet binders on the cask lid must be torqued to 10010 ft-lb.

Il i

f

13. The cask body and each cask lid must be marked in accordance with 10 CFR 571.85(c).

y!

Thepackagesauthorizedbythiscertificatemustbetransportedonamotorvehicle,lll g

14.

E railroad car, aircraft, inland watercraft, or hold or deck of a seagoing vessel

I E

assigned for the sole use of the licensee.

+

il

[

I lI
---------------v-v---------------------------------s

t W

l R conoursons tcomonucs)

W *

l l

1 l

i I

^

71-9177

'I I

.Page 4 - Certificate No. 9177 - Revision No. 6 - Docket No.

lI I

llI l

t i

g

15. The packages authorized by this certificate are hereby approved for use under the lI g-general license provisions of 10 CFR 571.12.

lll 5

I l

I 16.

Expiration date: May 31, 1998.

il I

ll i

I ll l

ll REFERENCES I

I I

Nuclear Packaging, Inc. application dated February 29, 1988.

l N

jI l

Supplements dated: April 19, 1988; and February 16, 1993.

j I

I g

NUS supplement dated:

November; 22', 1985:

g a

'g i

LN Technologies Corporation supplement dated:

February 16.-1988.

I I

I l

Scientific Ecology Group, Inc., supplement dated: April 30? 1993.

!lg g

J'.

g FOR THE U.S.-NUCLEAR REGULATORY COMMISSION

!I R

!\\

I E

Charles E MacDonald, Chie I

l 2 Transportation Branch

[2 j

g Division of_ Industrial an~d q;

MAY 2 01993

Medical' Nuclear Safety, NMSS
I l

m.;;

3e i

,i it Date:

(

j~ -

(l ll

~

l g

I g

-e g

R R

i

+l

?

lll t

I

I I

l i

(

I i

!I I

I I

I I

l l-iI l

i

,1 d

il l

5 i

j E

l1 I

l u

I 1

I

'I E

I i

s i

i i

I

)

l l

1

-l i

I I

1 l'

I 1

I

)

I

I I

il 1

.=.

./ '*%,

y.-

-4 %

UNITED STATES l

2

-E NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20Eli6-0001

%,...../

i APPROVAL RECORD Model Nos. NUPAC 10/140 and LN 10-135A Certificate of Compliance No. 9177 l

Revision No. 6 l

By. application dated February 16, 1993, Pacific Nuclear Systems, Inc. (PNSI),

i requested renewal of Certificate of Compliance No. 9177 for the Model No.

NUPAC 10-140 package. Also, by application dated April 30, 1993, Scientific Ecology Group, Inc. (SEG), requested renewal of Certificate of Compliance No.

9177, for the Model No. LN 10-135A package.

PNSI or SEG did not make or request any changes to the package design.

PNSI, the certificate holder, requested that the certificate be revised to l

incorporate their company name and address.

The certificate has been revised i

accordingly.

t The staff has reviewed previous submittals, including the operating procedures, acceptance tests and maintenance programs, and have found them to 4

be complete and adequate.

1 i

The Certificate of Compliance has been renewed for a five year period which l

expires May 31, 1998.

Charles E. MacDonald, Chief -

Transportation Branch Division of Industrial and I