i lO-I May 17,1993 j

Docket Hos.50-003 Distribution:

l and 50-247 Docket: File 4 OGC l

NRC & Local PDRs ACRS (10) l Mr. Stephen B. Bram PDI-l P,eading CCowgill, RI Vice President - Nuclear Power SVarga RSkelton, 9/D/24 Consolidated Edison Company CMiller PMcKee, 9/D/24 of New York RAcapra PErickson,'11/B/20 Broadway and Bleakley Avenue CVogan EHylton, 11/B/20 l

Buchanan, New York 10511 FWilliams RKeimig, RI l

Dear Mr. Bram:

1 l

SUBJECT:

REVIEW 0F SECURITY PLAN CHANGES PURSUANT TO 10 CFR 50.54(p) l l

INDIAN POINT NUCLEAR GENERATING UNIT NOS. 1 AND NO. 2 i

I (TAC N0. M86322) l This is in response to your letter of March 41993, submitting proposed Physical Security Plan changes, Revision 14, for the Indian Point Unit Nos. 1 and 2.

The issues contained in those revisions are considered to be policy l

l issues and have been referred to the Office of Nuclear Reactor Regulation for.

{

review.

l Based upon our initial review, additional information is necessary to I

determine the acceptability of those changes under the provisions of 10 CFR l

50.54(p)

So that we may complete our review, please provide information l

requested in the enclosure to this letter.

The enclosure to your letter contained Safeguards 'Information of a type specified in 10 CFR 73.21 and is being withheld from public disclosure.

l l

This requirement affects one respondent and, therefore, is not subject to l

Office of Management and Budget review under P.L.96-511.

Sincerely, Original Signed By:

Francis J. Williams, Project Manager Project Directorate I-1 Division of Reactor Projects I/II l

Office of Nuclear Reactor Regulation

Enclosure:

As stated cc w/ enclosure:

See next page

  • SEE PREVIOUS CONCURRENCE LA:PDI-l PM:PDI-I PSGB D:PDI-I CVogan-W IhlIams:smm
  • PMcKee RACapra I i /93 T/1)93 05/14/93 0 5 // 7/93

/ /

/ /

1

/

OFFICIAL RECORD COPY FILENAME: IP286322.LTR 9305200222 930517

~

l PDR ADDCK 05000003 F

PDR l

r

i q

f(

t UNITED STATES

[

j NUCLEAR REGULATORY COMMISSION l

f WASHINGTON, D.C. 20666-0001

\\....* /

May 17,1993 Docket Nos.50-003 and 50-247 l

l Mr. Stephen B. Bram Vice President - Nuclear Power Consolidated Edison Company of New York Broadway and Bleakley Avenue Buchanan, New York 10511 t

i

Dear Mr. Bram:

SUBJECT:

REVIEW 0F SECURITY PLAN CHANGES PURSUANT TO 10 CFR 50.54(p)

I INDIAN POINT NUCLEAR GENERATING UNIT NOS. 1 AND NO. 2 (TAC NO. M86322)

This is in response to your letter of March 41993, submitting proposed Physical Security Plan changes, Revision 14, for the Indian Point Unit Nos. 1 l

and 2.

The issues contained in those revisions are considered to be policy l

issues and have been referred to the Office of Nuclear Reactor Regulation for review.

1 I

Based upon our initial review, additional information is necessary to determine the acceptabilit,y of those changes under the provisions of 10 CFR 50.54(p). So that we may complete our review, please provide information requested in the enclosure to this letter.

i The enclosure to your letter contained Safeguards Information of a type j

specified in 10 CFR 73.21 and is being withheld from public disclosure.

j l

This requirement affects one respondent and, therefore, is not subject to Office of Management and Budget review under P.L.96-511.

l Sincerely,

'I < %

0 i

d UAbf A-

ana, F ancis J.

liams, Projectflanager Project D r ctorate I-l

)

l Division f Reactor Projects I/II i

Office of Nuclear Reactor Regulation i

Enclosure:

As stated cc w/ enclosure:

See next page 190662 n

-. 7wvn e~M it l

1

4 Mr. Stephen B. Bram Indian Point Nuclear Generating Consolidated Edison Company Station Units 1/2 of New York, Inc.

CC*

Mayor, Village of Buchanan Charles Donaldson, Esquire 236 Tate Avenue Assistant Attorney General Buchanan, New York 10511 New York Department of Law 120 Broadway Ms. Donna'Ross New York, New York 10271 New York State Energy Office 2 Empire State Plaza Mr. Peter Kokolakis, Director 16th Floor Nuclear Licensing Albany, New York 12223 Power Authority of the State of New York Mr. Charles W. Jackson 123 Main Street Manager of Nuclear Safety and White Plains, New York 10601 Licensing Consolidated Edison Company Mr. Walter Stein of New York, Inc.

Secretary - NFSC Broadway and Bleakley Avenue Consolidated Edison Company Buchanan, New York 10511 of New York, Inc.

4 Irving Place - 1822 Senior Resident Inspector-New York, New York 10003 U. S. Nuclear Regulatory Commission Post Office Box 38 Regional Administrator, Region I Buchanan, New York 10511 U. S. Nuclear Regulatory Commission 475 Allendale Road Mr. Brent L. Brandenburg King of Prussia, Pennsylvania 19406 Assistant General Counsel Consolidated Edison Company of New York, Inc.

4 Irving Place - 1822 New York, New York 10003

O T.

ENCLOSURE REQUEST FOR ADDITIONAL INFORMATION PHYSICAL SECURITY PLAN INDIAN POINT NUCLEAR GENERATING UNITS NO. 1 AND NO. 2 CHAPTER PAGE COMMENT 1

N\\A Include the updated Figures 1.1 and 1.2.

3 3-7 Regulatory reference (10 CFR 73.2(f)(1)) is incorrect.

please review all regulatory references and correct as necessary.

t 3

3-12 An unmarked change regarding the manning of the access e

portals is an unacceptable change under the provisions of 10 CFR 50.54 (p).

Revert back to previous plan commitments.

3 N\\A Include the updated Figures 3.1, 3.2, 3.3, 3.4, 3.5, 3.6, 3.7, and 3.8.

5 5-4 Editorially correct the word " genetic" barrier.

7 7-5 Same comment as 5, 5-4.

f B

B-1 Replace this missing page.

B B-2 Remove the superseded definition for "No-man's Land."

i l

t

-