Responds to 920324 Memo Re NRC Region II Request for Guidance on Transfer of Contaminated Equipment by Itt Under Specific License to General License.Recommends That Itt Decontaminate Saw Per Current Guidelines
ML20044B509
Person / Time
Issue date: 04/29/1992
From: Joseph Austin
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Glenn J
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
Shared Package
ML20044B510 List:
References
HPPOS-281, HPPOS-284, NUDOCS 9205050249
Download: ML20044B509 (1)


Text

-

l - -,. c. ~

d

  • a atc p

oq s'

h r

7, UNITED STATES i.! 7 '

i NUCLEAR REGULATORY COMMISSION Y

b I[

WASHINGTON. D C. 20555 s-

..4y

\\...'.. #

APR 2 9 ra2 MEMORANDUM FOR:

Jchn E.

Glenn, Chief Medical, Academic, and Commercial Use Safety Branch Division of Industrial and Medical Nuclear Safety, NMSS FROM:

John H.

Austin, Chief Decommissioning and Regulatory Issues Branch Division of Low-Level Waste Management & Decommissioning, NMSS

SUBJECT:

TRANSFER OF A CONTAMINATED SAW TO A GENERAL LICENSE I am responding to your memorandum of March 24, 1992, regarding the Nuclear Regulatory Commission Region II's request for guidance on transfer of contaminated equipment by ITT under a specific license to a general license.

Based on our meeting with your staff and OGC on April 29, 1992, we understand that (1) ITgg is now only requesting transfer of a saw, witp a maximum fixed Th surface contamination of 10,000 dpm/100 cm, to gge general license, and (2) the polishing compound containing Th, which was previously used at this facility in a grinding operation, is actually a rare-earth compound that is exempt under 10 CFR Part 4 0.13 (c) (1) (vi).

In view of this new information, we recommend that ITT decontaminate the saw in accordance with the maximum fixed '4 pes for decontamination of equipment current guidel (average and 2

Th surface contamination of 1000 dpm/100 cm and 2

3000 dpm/100 cm, respectively) prior to termination of the specific license and release of the saw for unrestricted use.

If this level of cleanup is not achievable, ITT should decontaminate the saw to an alternative level that is "As Low As Reasonably Achievable" (ALARA). _If the licensee decontaminates the saw to ALARA levels (in excess of existing guidelines), we see no reason to object to transfer of the saw from a specific license to a general license.

If you have any further questions, please contact Boby Eid of my-staff at 504-3446.

Ib.

J hn H. Austin, Chief Decommissioning and Regulatory Issues Branch Division of Low-Level Waste Management & Decommissioning, NMSS e

~