ML20044B018

From kanterella
Jump to navigation Jump to search
NPDES Noncompliance Notification:On 900706,limited Fish Kill Discovered in Plant Circulating Water Discharge Bay.Caused by Thermal Shock from Increasing Discharge Temps Combined W/Fluctuating Water Levels in Facility Reservoir
ML20044B018
Person / Time
Site: Summer 
Issue date: 07/11/1990
From: Bradham O, Summer S
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Krecker W
SOUTH CAROLINA, STATE OF
References
NUDOCS 9007170209
Download: ML20044B018 (6)


Text

__

i gtgth Car ime Elsetr6c & Gas Ctmpany 0 10 S. Brad m g,ngggs,c mes weis., oner.i no SO E July 11, 1990 a= :~,

Mr. William R. Krecker Environmental Quality Manager Water Quality Assessments & Enforcement Division

-South Carolina Department of Health

& Environmental Control 2600 Bull Street s

Columbia, South Carolina 29201

SUBJECT:

Virgil C. Summer Nuclear Station Docket No. 50-395 C>l. o I't - O--

Discharge Bay Fish Kill -

July 6, 1990

Dear Mr. Krecker:

South Carolina Electric & Gas Company (SCE&G) herewith submits a report concerning a recent fish kill which occurred in the circulating water discharge bay of the Virgil C. Summer Nuclear Station (VCSNS).

The enclosed report describes the event and provides a probable cause. As noted in our previous correspondence on this matter, SCE&G is investigating the fish kill issue and plans to arrive at a viable solution by the Fall of 1990.

In accordance with the VCSNS Operating License NPF-12, Appendix B, a copy of this report is being provided to the Nuclear Regulatory Commission.

Additionally, a copy of the report will be provided to the South Carolina Department of Wildlife & Marine Resources per the request of Mr. H. J. Logan, Chief of Fisheries.

If you have any questions, please call Mr. Charles McKinney at 345-4723.

Very truly yours, i

0. S. Bradham EWR/OSB:nkk Attachment c: 0. W. Dixon, Jr./T. C. Nichols, Jr.

M. B. Williams Central Midlands District W. M. Lide, Jr.

Val Nash L. A. Blue HSRC R. R. Mahan NPCF S. f. Summer-,

RTS (ONO9000B1) iDocument;ControfDesO,,

j File (809.06-1 & B18.05)

'NRC Resident: Inspector 9007170209 900711 PDR ADOCK 05000393 g

S PDC

'\\\\

L,.

i I

4.

Fish Kill Report 7/6/90 A limited fish kill was discovered in the Virgil C. Summer Nuclear Station circulating f

water discharge bay on 7/6/90. The apparent cause is thermal shock from increasing discharge temperatures combined with fluctuating water levels in Monticello Reservoir caused by the operation of Fairfield Pumped Storage Facility. There were no unusual discharges from V. C. Summer Nuclear Station (VCSNS) which could have contributed to the kill. VCSNS operated at approximately 100% power t!.ioughout the time penod in ouestion. Table 1 shows the numbers and iCntification of the fish killed. Figurr,1 shows the location of the fish kills. Based on the temperature data presented in Figure 2, the fish were probably killed late at night on 7/5/90 when the circulating water disr.narge temperature (as measured in the plant) exceeded 106'F. The time of hottest discharge temperatures correlates with low reservoir levels. On the bottom of the discharge bay, where the kills probably occurred, the temperature reached approximately 105'F. Table 2 shows the lake levels and the corresponding intake and discharge temperatures from V. C. Summer Nuclear Station. More detailed data is available and will be presented to the South Carolina Wildlife and Marine Resources Department and the South Carolina Department of i

Health and Environmental Control with the quarterly fish kill study data.

ww

5. E. Summer h

l c

L L

i

~.,.

w+

I 3-*)

3i 3

y 3 l iu-

.fglD s

e.g

,,,e y 'i ;l '

r. ', :- i..

' e:

k!

. m.

~- e m. A, v>_eA i

, ;;e.

J Table 1 if.

v.

g.

7/6/90 E

s 1.

J-

.:(

  1. Fish Species.

. Size Ranae ~

1

$E : o 19 white catfish

. 5 - 10 inches:

~

)~

5'

-3 channel catfish 5 - 18 inches 4-D 3

. bluegill l

4-5 inches 4

28 unidentified sunfish

  • 3 - 6 inches

-e 3

gizzard shau 10 12 inches e<

i

'k s

  • badly decomposed 1

b

t u

F t

+

i 5['[.f 4

i f

L I

Je

\\*l P

,k_

1 v

4 t.

t' t

.a a,

I

,i-.' <

']

L,:.

2 ;

1,.

['

'3II 4

3

[l i 4 7

i

?!

. Ift ig r

l.

e lV, Y

N I(

L.

m s

g..

,,i,',

y

-: (, !

.3,=

' 1 p I.

l>

.pt c

ll;-

I, l '., \\

..t

II,

'~

F

    • ?,

k y

?

-_-,"_,!i--t j

' {

h*,~,

_~

g yi ['b R,6lf.!;I. '_

' "Y

'y' 7 -:, e >

!S'>)f

~

~

Figure.. Il

.it i

s

.,e~

e:

Myi "Y

l Monticello i,6 Reservior+:

1 J

U

/

SERVICE WATER POND p

Discharge Canal I

f B oy' f

8uoy

~

' #1 Discharge' Bay

/

+

4 N Location 4 of.

Fish Kill-I:: $.

b; 3

b;#.

fw n

o; 1g.,A lClRCULATING WATER DISCHARGE

r-7 3

3:

TABLE 2 s

Lake ltvel intake

  • Discharge
  • Lake i.evel intake
  • Discharge *
Date Hour (Feet)

Temp *F Temp *F Date Hour (Feet)

Temp *F Temp *F -

7/4/90 0100

.422.9 ND ND 7/5/90 0100 e:2.9 80.1 105.5 0200 423.1 ND ND GOO 423.2 79.1 104.6 r

?

0300 423.4 ND ND 0300 423.5 78.9 104,4:

0400 423.7 ND ND 0400 423.8 78.6 104.1 0500 424.0 NL)

ND 0500 424.1 78.5 103.9 l

0600

,424.4 ND ND 0600 424.4 78.4 103.9 0700 424.6 ND ND 0700 424.6 78.4 103.9' 0800 424.7 ND ND 0800 424.8 78.3 103.8 0900 424.7' 78.6 104.1 0900 424.9 78.4 103.8 i

1000 424.6 78.7 104.1 1000 424.9 78.5 104.0 1100 424.4-78.4 103.8 1100 424.8 78.8 104.2 j

1200 424.2 78.3 103.7 1200 424.5 79.0 104.4 1300 424.0 78.2 103.6 1300 424.1 79.5 104.9 1400 423,7 78.7

'104.1 1400 423.6 80.1 105.4-1500 423 4 79.4 104.7 1500 423.2 81.2 106.5 1600 42 3.~2 79.3 104.7 1600 4?2.7 81.2 106.6 s

1700 422.9.

79.5 104.9 1700 422.2 81.4 106.8 x

1800 422.7 79.8 105.3 1800 421.8 81.2 106.5 1900 422.6 80.3 105.8 1900 421.3 81.2 106.6 l:

2000 422.6 80.5 106.0 2000 421.1-80.9 106.4 l-

-2100-422.5 80.6 106.1 5100 420.8 80.9 106.2

~

1-2200 422.4 80.3 105.7 2200 420.8 80.8 106.2 2300-422.4 80.1 105 6 2300 421.1 ND ND-0000 422.6 80.0 105.4 U000 421.5 ND ND~

-ND = No Data e

z

(-

1:-

1 '

.a e

ij.\\

t' 19 '{.

.i

.9. v

g..

I

)

t 4

11

'$l.

b I

g v{}.,.

y>

1s

.:f . - n E. ( '..

[3, ( i; R I

> V.

a2-

,.f ',

ay s

d W

e.e

    • j p

b W

/'p.

OH 1

2

~%

g 4

s,._4 -.

.m 4

w f*

9 %'

' I,

\\

'i c'

1

,/ "

e*"

f.

'n.

\\

s N

  • )

t 4

g 8

4 3

L.

- *1

. =

4 s.

, m_

,,d-i

.-W

./

i g

4

~

w n

x.

.-~

i, A t-

)

S '.

i

1. ; -..

u s

@ [*;

Q[

/

t,

( ri n g.g i <

e s

l=est

.g

  • h

- (* w 4 (m

yy

.j 4

l

'.T

. e.

a.

m.

m.

e.

m..

o-b i

y.

4 r,:;

e

! S 5.,

"I n +;q,,

t e nfiq., '..

L.

,.lyp ((1 tY ' y

.)

i -

y/