ML20043G426

From kanterella
Jump to navigation Jump to search
Amend 146 to License DPR-65,changing Tech Spec 5.6.1(a) to Allow Enrichments Up to 4.5 Weight Percent U-235 to Be Stored in New Fuel Storage Racks & Tech Spec 5.3.1 to Permit Max Fuel Enrichment of 4.5 Weight Percent in Reactor Core
ML20043G426
Person / Time
Site: Millstone Dominion icon.png
Issue date: 06/13/1990
From: Stolz J
Office of Nuclear Reactor Regulation
To:
Connecticut Light & Power Co, Northeast Nuclear Energy Co (NNECO), Western Massachusetts Electric Co
Shared Package
ML20043G427 List:
References
DPR-65-A-146 NUDOCS 9006200277
Download: ML20043G426 (3)


Text

,

h!

'o,,

UNITED STATES f,

NUCLEAR REGULATORY COMMISSION e,j WASHINGTON, D. C. 20655 3

r, -

\\

  • %*..../

NORTHEAST NUCLEAR ENERGY COMPANY l

THE CONNECTICUT LIGHT AND POWER COMPANY THE WESTERN MASSACHUSETTS ELECTRIC COMPANY DOCKET NO. 50-336 MILLSTONE NUCLEAR POWER STATION, UNIT NO. 2 AMENDMENT TO FACILITY OPERATING LICENSE' Amendment No.146 License No. DPR-65 1.

The Nuclear Regulatory Commission (the Commission) has found that:

A.

The application for amendment by Northeast Nuclear Energy Company, etal.(thelicensee), dated' April 10, 1990,- complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth.in 10 CFR Chapter I; B.-

.The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with'the Commission's regulations; D.

The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.

I.

9006200277 900613 PDR ADOCK 05000336 P

PDC

l 2

2.

Accordingly, the license is amended by changes to the rechnical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-65 is hereby.

amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendix A, as revised i

through Amendment No.146, are hereby incorporated in the license.

The licensee shall operate the' facility in accordance with the Technical. Specifications.

3.

This license amendment is effective as of the date of issuance, to be implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

]gJ..

JohF.Stolz,Directo/r Pr ject Directorate I-Dt ision of Reactor h0jects - 1/II Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

June 13, 1990

ATTACHMENT TO LICENSE AMENDMENT NO.146 FACILITY OPERATING LICENSE NO. DPR-65 DOCKET NO. 50-336' Replace the following pages of the Appendix "A " Technical Specifications with the enclosed pages. The revised pages are identified by amendment number and contain vertical lines indicating the areas of change. The corresponding overleaf pages are provided to maintain document completeness.

Remove Insert 5-4 5-4 5-5 5-5 i