ML20043F751

From kanterella
Jump to navigation Jump to search
Special Rept Spr 90-006:all Tech Spec Reporting Requirements Resulting from Measured Forces Below Current Acceptable Values During Fourth Tendon Surveillance.No Abnormal Degradation of Containment Tendons Occurred.W/O Rept
ML20043F751
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 05/29/1990
From: Bradham O
SOUTH CAROLINA ELECTRIC & GAS CO.
To: Ebneter S
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
SPR-90-006, SPR-90-6, NUDOCS 9006180078
Download: ML20043F751 (1)


Text

-'

4 3 , ,,

c South Cir:Hns Electric & Gas C rnpany oll6e S Bradhim Ji i svilt SC 29065 - ' ucio r r Sons

, (803) 345-4040 L ,

.SCEAG May 29, 1990

$$ M 4 A$! $$

Mr. S. D. Ebneter Regional Administrator U. S. Nuclear Regulatory Commission

, Region II, Suite 2900

.101 Marietta Street, N. W.  ;

Atlanta, Georgia 30323 i

Subject:

Virgil C. Summer Nuclear Station j Docket No. 50/395  !

Operating License No. NPF-12 i Special Report (SPR 90-006)

Dear Mr. Ebneter:

l Pursuant to the Virgil C. Summer Nuclear Station Technical Specifications, Section 3.6.1.6 -Action b, South Carolina Electric and Gas Company (SCE&G) is i forwarding the attached document, " Reactor Building Containment Fourth Period Surveillance Tendon Forces," as a 30-Day Special Report for the tendon surveillance completed on April 30, 1990.

The attached report documents the fourth tendon surveillance and includes all Technical Specifications reporting requirements resulting from the measured'

~ forces that were below the current acceptable values. The conclusions of L the report indicate that no abnormal degradation of the containment tendons .

! has' occurred. Also, the prestress in the containment continues.to be above the design requirements and, due.to a decision to re-tension the vertical tendons, is predicted to remain as such for at least the next 25 years.

Should you have any questions please call at your. convenience.

l Very truly yours,.

g f f[.,

O. S. Bradham DCH/0SB:1bs Attachment ~

OiW.Dixon,Jr./T.C.Nichols,Jr.

E. C. Roberts R. V. Tanner R. L. Prevatte 1

. General Managers Marsh & McLennan i g J.'J.- Hayes, Jr. Document Management Branch zC. A. Price INP0 Records Center R. B. Clary ANI Library J..R. Proper NSRC K. E. Nodland NPCF J. C. Snelson RTS (ON0900008)

J. B. Knotts, Jr. File (818.05 & .818.08) 9006180078 900529 4 gDR ADOCK 0500 5