ML20043F074

From kanterella
Jump to navigation Jump to search
Owners Data Rept for Inservice Insps
ML20043F074
Person / Time
Site: Crane 
Issue date: 06/04/1990
From:
GENERAL PUBLIC UTILITIES CORP.
To:
Shared Package
ML20043F067 List:
References
NUDOCS 9006140141
Download: ML20043F074 (36)


Text

{{#Wiki_filter:.- l A O FORM NIS.1 OWNERS' 3ATA REPORT FOR INSERYlCE INSPF.CTIONS As required by the Provisions of the ASME Code Rules

1. Owner Metropolitan Edison Company, 2800 Pottsville Pike, Reading. Pennsylvania I

(Name and Address of Owner)

2. Plant Three Mile Island Nuclear GeneVating Station, Rte 441.So., Middiciown,

{ (Name ara Address of Plant) Pennsylvania Unit 1

3. Plant Unit
4. Owner Certificate of Authorization (if required)

None

5. Commercial Service Date 09/02/74
6. National Board Number for Unit _REadL 81ASC1 1L-109_
7. Components inspected See Table 1 Manufacturer Component or Manufacturer or installer State or National Appurtenance or installer Serial No.

Province No. Board No. \\ \\ N 'N 'x ,w. sur,5 N A ~' j 6 ', \\ \\ x 'N N \\ \\ N Note: Supplemental sheets in form of lists, sketchen, or drawings may be used provided (1) site is 8 % in. x 11 in., (2) information in items 1 through 6 o e this data report is included on etch sheet. and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. This frem (E00029) rnay 1 e obtained from the Order Dept., ASME, 345 E. 47th St., New York, N.Y. 10017 . g (4 i C D' O s

,P

  • FORM NIS 1 (back)
8. Examination Dates 08/16/88 03/04/90 9. Inspection Interval from _1974 to _1991 to
10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required for current interval. See Table 1.

The 3nservice inspection required for this interval is approximately 95% completed.

11. Abstract of Conditions Noted See Table 2.
12. Abstract of Corrective Measures Recommended and Taken See Table 2.

We certify that the statements made in this report are correct and the craminations and corrective mes-sures taken conform to the rules of the ASME Code, Section XI, e NDE/ISI Services ._h - Date MW L5 19_Tp_ Signed Manager __ n y Owner Certificate of Authorisation No. (if applicable) NA Expiratmn Date NA CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and/or the State or Pr< wince of.LeJU1Rylya_niA_ and employed by Ha r t f ord Steam Boilegf I&I Co. Ilartford, Conn have inspected the components described in this Owners' Data Report during the period 08/16/_88 to 03/04/90 . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners' Data Report in accordance with the requirements of the ASME Code, Section XI. Hy signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this owners' Data Report. Furthermore, neither the inspector n-his employer shall be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with this inspection. Date MA435 19.9 0__ _ Commissions PA-1887 @ $476 i in iccto s'[ignature National board, State, Province and No. l I e ')

7 Es a. d 4 ( i FORM Nis 2 OWNER'S REPORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1.Owne. Metropolitan Edison-Company 04-04-90 - 2800 Pottsville Piksemme Reading, Pennsylvania 1 1 Sh"' 'I r Acorm 2 Plant Three Mile Island Nuclear Generating Stg,gion 1 Name BAe 123228 J06 A25E-V1225 b Route 441 South Middletown, Pennsylvania wag A25E-53228 MNCR6 880107 Adorous Hopeir oreenisetion P.o. No., Job No., etc.

3. Work Performed by GPU Nuclear NA Type Code Symbol Stomp Nem*

.100 Interpn 4 Pkwy. Authorizati n No. NA o-l- Parcippany, New Jersey Empiration Date NA } Address

4. Identification of System Decay lleat Removal 69
6. (a) Applicable Construction Cod, USAS D31. 7 39
Edition, Addenda, Code Case

. (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 1974 Edition with addenda through Summer 1975, l

6. Identification of Componenu Repelred or Replaced and Replacement Componente ASME Code Nationel
Repaired, Stemped Name of Name of Manutecturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

N o. Identification Built or Replacement or No) Support NA NA NA-Dilli-108 A 1974 Repaired No l Performed weld build-up to undersized integral attachment welds'

7. Description ot work on support Dlill-108A.

[- 8.' Tests Conducted: Hydrostatic C Pneumatic 0 Nomina Operating Pressure O Other @ Pressure pel Test Temp, 'F See Remarks NOTEi Supplemental sheets in form of lists, sketches, or drowings may be used, provided (1) size is 8% in. x 11 in., (2) informs-- tion in items 1 through 6 on this report la included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form. (12/82) This Form (E00030) may be obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y. Ir417 I 1_

?s e e I FORM NIS 2 (Bock)

9. Romerks.D_fM9.Dej r a n ( AD,d.,,,v i s u a 1.. e xjftth ions were Jp,IfOrmt,4 E _tJ1p final fillet AppHcatWe Manufecturers Dete Reports to t>e etteched

_.Wcidm2Ic.11ktte_ tests are not required. l ? CERTIFICATE OF COMPLIANCE We certif y that the statements made in the report are correct and this. repa i r conforms to the rules of the "D * P ' *C ' * * "1 ASME Code, Section X1, Type Code Symbol Stamp NA p Certifkete Authorlietion. No,-, NA Expiration Date NA NDE/ISI y Signed Servico8 Manage __r_pg, J Af 2 6 -.,1932 Owner or Owner's Designee, T6tle i CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid cornmission issued by the National Board of Boller and Pressure Vessel inspectors and the Stetc or Province of Pennov1vania end ems.:oyed by Hartford Steam Boiler I&I Co. og Hartford, Conn. have inspected the components described 1 in this Owner's Report during the period. 08-17-88 04-04-90 to . and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in eccordence with the requirements of the ASME Code, Section XI, By ugning this certificate neither the Inspectos nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in 4his Owner's Report, Furthermore, neither the inspector nor his employer shall be lieble in any menner for any personal injury os property damage or a loss of any kind erlaing from or connected with this inspection. 00 NO MI6 ~ Commissions _ nspector's Signatug Nettonal Doerd, State, Prov6nce, and E ndorsements Date $._.Ay 22 $ 19.f0 I (12/82) 1 f i

  • 1

.s. i, M. [~ l-k L FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS At Required by the Provisions of the ABME Code Section XI Metropolitan Edison Company i 04-04-90

t. Wer Date 2800 Pottsville Pike "*"

f

Readinef, PennsyJ1yania

$3,,, 1 1 y n o g Addrew ' 2. Plant Three Mile Island Nuclear Generating Stap pn 1 Route 441 Sout - t Middle 1QyL_EtnTL8,ylvania f Jcb Tickets CR721 and CR727 Addrese i Mooelt Orsentretion P,0. No., Job No., etc. l

3. Work Performed by - GPU Nuclear _

Type Code Symbol Stamp _ NA i' 100 Interpace Pkwy"*** Authorization No. NA 2ArriprAn.L_LL Expiret 9 Date NA Addrees 4 IdentHication of System Main Steam ( i+ \\

5. (a) Applicehle Consvuction Code.A.,NSI B31.(1 10E Ednion, NA NA Addende.

Code Caw (b) Applicable Ednlon of Section XI Otilised for Nepairs or Repisownents 19 74 with Addenda thru Summer 1975. p f i

6. Identification of Coneonents Mepaired or Replaced 6nd Replacement Components 5-ASME Code Neolonal Repair 6d, Stemped Manufacturer 84srd Other Yee
Replaced, (Yes Name of Name of

-3 Component Manuf acturer ' Serial No. No, identification Built or Replacement or No) HancockMff.' NA NA MS-V-74A 1974 rep aced No l 1 1/2" Valve Co. il Hancock Mft. ' -1 1/2". Valve A, NA MS-V-74B 1974 Replaced No Co. v I % 1 \\ Replace valves MS-V-74A and MS q-74B

17. Description ot Work i-Hydrostatic 0 Pneumatic 0 Nominst Operating Press fe @

t 8. Tests conducted: NA Other O Pressur, 900 psty Test Temp. yp NOTEi Supplemental sheets in form of lists, sketches, or drowings rney tw used, provided (1) stre la 84 in. = 11 in., (2) Informe. tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet js numbered and the number of sheets is - recorded at the top of this form. (12/82) - This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 _ = = _ _

J is, )l, ty .l a-

r e

FORM NISJ (Back) 9 Remark s NA As+1g able %Aariviactu er's pate Reports to be attached r -w-n.--- ~~ CERTIFICATE OF COMPLIANGE We certif y that Ibsemelhade in the teport are correct and this LCM 10ECEQE1 conf orms to the rules of the D'""'"'*""' ASME Code, Section XI. Type Code Symtwai Stamp-- -E Certificate of Authoritatiod. M _. - __ __. E x pirat ion Date _ NIL _._._.___ f/ NDI:/ISI / Signed 4. M SOTvices !4anagU Det,_[2h 2[ ,1g 9 0 o.nor or ownertmass CERTIFICATE OF INSERVICE INSPECTION I, the unoers'0ned, holdingla6 colton issued by the National Board of Boiler er.d Pressure Vessel Inspectors and the Stats or Province of.EennSdMa 9d employed by}{& r t f o rd.Ji_egm_J}qdM_lM_QQt of e lia r t f ord, Conn. nave inspected the components descrited in this Owner Report duritme g08 8_8_ _ to_ Q4-Q1-90 , and state that to the test of niy knowledW N bedowner has pertormed enam.nationy and taken corrective measures described in this Owner's Report in acco*dancest thahents of the ASML Code, Seg;N XI. By signing this certificate nther pedictor not his ernployer ma/es any warranty, expressed or impiied concerning the / exammations and correctie seuuratilted in this Owrer's A* mrt. F urthermore, neither the inspector nor his empiover shall be liabi, in any manwgeny pakry or property d-nage or a loss of any kind arising f rom or connected with this inspection / E PA-1887 N8 978 W Commissions ~~ specErsspture Nations' Board State. Province, and E ndorsements cate____/WdL.MI ___i6 (12/82)

ym S n \\ y a a i i' i 6 \\ l P.., FORM NISO (Back)

9. Flemarks NA s

Applicable Manuf acturer's Data Reports to tse ettsched 3 ( 4 5 \\ CERTIFICATE OF COMPLIAN *E We certify that the statements made in the report are correct and this RCD 1 Acement conforms to the rules of the lD**''D'***'"*"' ASME Code, Section XI. i I Type Code Symtcl Stamp NA / NA Expiration Oate NA Certificate of Authorization No,_ s NDE/ISI Signed Services MaIIASM Dete./.OMY ' E 10 90 Owner or owner's Designee. Title i CERTIFICATE OF INSERVICE INSPECTION 1, the under:10ned, holding a valid commission issued by the National Doord of Bollet and Pressure Vessel inspectors said the State or Province of Ponnsylvania endomployed bylIa. rtf ord Steam holler I&I Co. ,,, o g liartf ord r Conn. $$ve inspected the components described { in this Owner's Report during the period- 08-17-88 to 64-04-90 . and state that to the best of my knowledge and belief, the Owner has performed examination /end taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Se Nve/n XI, Dy signing this certificate neither the Inspector nor his ernployer mpes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owrer's R ort: Furthermore, neither the inspector nor his employer shall be liable in any menner for any personal injury or property d nage or a loss of any kind arising f rom or connected with this inspection, / / ' Commissions Eb'1007 W b S41 spector's Sifture l Nationet Board, State, Province, and E ndos.ements I 0! Date $5 Ck[ 19 (12/82) / i

p ey- ,g C WIS 1 OWNEkl DATA REPORT FOR INSERVICE INSPECTION 1. OWNER: Metropolitan Edison Company, 2000 Pottsvitte Pike, ReadinB, Pomsylvania 2. PLMit Three Mlle Island Nuclear GeneratinB Station, Route 441 South, Middletown, Pennsylvania 3. PLANT UNIT: 1 4 OWNER CERTIFICAfl0N OF AUTMCdtlZAfl0N (if regilred): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NAfl0NAL 804RD AMBER FOR UNIT Reactor Vessel N 109 OUTAGE 8R TABLE 1 ASME ASME lNDE l l CAT, ITEM No SYS1EM / COMPONENT COMP 0NENT ID DESCRIPil0N lMETH l MAT l DIA REMARKS ......o.......+.................................+.............+......................+....+........+........+..................... 1

  • * *
  • IN SERVICE EXAMINAfl0NS ****

BC B1.3l RC / Reactor vessel RC 11 l RH 0001 l Head to FlanBe Weld l UT ' CS

159 Examined adjacent to stud holes 40 thru 1.

BG1 B1. 8 RC / Reactor vessel RC 11 RM 0041 Head Stud and Wut UT CS 6.5 BG1 B1. 8 RC / Reactor vessel RC 11 RM 0041 Head Stud and Nut MT CS 6.5 BG1 St. 8 RC / Reactor Yesset

  • RC 11 RK J042 Head Stud and Nut UT CS 6.5 BG1 B1. 8 RC / Reactor Vessel
  • RC T1 RH 0042 Head Stud and Wut MT CS 6.5 BG1 B1. 8 RC / Reactor Vessel RC T1 kH 0043 Head Stud and Nut UT CS 6.5 BG1 St. 8 RC / Reactor vesset RC-T1 RN 0043 Head Stud and Nut MT CS 6.5 B01 B1. 8 RC / Reactor vessel RC T1 RN 0044 Head Stud and Nut UT CS 6.5 s

BG1 B1. 8 RC / Reactor vessel RC 11 RH+0044 ' Head Stud and Nut MT CS 6.5 BG1 B1. 8 RC / Reactor Vessel RC T1 RN 0045 Head Stud and Nut UT CS 6.5 BG1 B1. 8 l RC / Reactor Vessel

  • RC-T1 RH 0045 Head Stud and Nut MT CS 6.5 BG1 B1. 8 RC / Reactor Vesset RC T1 RM 0046 Head stud and Nut UT CS 6.5 BG1 ti. 8 RC / Reactor Vessel RC T1 RM 0046 Head Stud and Wut l

MT CS 6.5 BG1 B1. 8 RC / Reactor Vessel RC T1 RM 0047 Head Stud and Nut UT CS 6.5 'BG1 B1. 8 RC / Reactor vessel RC T1 ' RM 0047 Head Stud and Nut MT CS 6.5 BG1 B1. 8 RC / Reactor Vessel RC T1 RH 0048 Head Stud and Nut UT l CS 6.5 BG1 B1. 8 RC / Reactor Vessel RC T1 RH 0048 dead Stud and Nut MT CS 6.5 'B 01

81. 8 RC / Reactor Vessel RC T1 RN 0049 Head Stud and Nut UT CS 6.5 BG1
81. 8 RC / Reactor Vesset RC 11 RH 0049 Head Stud and Wut MT CS 6.5 I

I l 1-05/24/90

ig Wit 1 OWNERS DATA Rf PORT FOR INSERVICE INSPECTION. 1. 0WNER: Metropellten Edloon Cogeny, 2800 Pottsville Pike, Readint, Pomsylvente 2. PLANT: Three Mlle latend Nuclear Generatlnt $tetton, Route 441 South, Middletown, Pennsylvente 3. PLANT UNIT: 1 4 OWNER CERTIFICAfl0N OF AUTHORIZATION (if rogstred): None 5. COB 94ERCIAL SERVICE DATE: 09/02/74 6. NATIONAL 90AkD NUMBER FOR UNIT: Reactor Yessel N-10') OUTAGE 8R TABLE 1 ABME ASME l NDE CAT ITEM NO SYSTEM / COMPONENT lCOMPONENTID DESCRIPTION METH MAT DIA REMARKS ......e.......e.................................+.............+................... .+.... +........+........+..................... BG1 B1. 8 RC / Reactor Vessel RC T1 RN 0050 l Head stud and Nut UT CS 6.5 BG1 B1. 8 RC / Reactor Vessel RC T1 RM 0050 Head Stud and Nut NT. CS 6.5 BG1 St. 8 RC / Reactor Vesset RC T1 RM 0051 Head Stud and Nut UT CS 6.5 i RN 0051 Head stud and Nut MT ' CS 6.5 BG1 B1. 8 tc / Reactor Vessel RC T1 l 1 BG1 St. 8 RC / Reactor Vesset RC-T1 RN 0052 Head $tud and Nut l UT CS 6.5 I BG1 B1. 8 RC / Reactor Vessel

  • RC T1

, RM 0052 Head Stud and Nut MT. CS 6.5 j. BG1 B1. 8 RC / Reactor Vesssel RC T1 RM 0053 Head Stud and Nut UT CS 6.5 BG1 B1. 8 RC / Reactor Vesset RC T1 RN 0053 Head Stud and Nut MT CS 6.5 l BG1 B1. 8 RC / Reactor Vessel RC T1 RM 0054 Head Stud and Nut UT CS-6.5 l BG1 St. 8 RC / Reactor Vesset - RC T1 .tH 0054 . Head $tud and Not NT N 6.5 i I BG1 B1. 8 RC / Reactor vessel RC T1 RH 0055 Head Stud and Wut UT 'CS 6.5 BC1 B1. 8 RC / Reactor Vessel RC T1 RN 005$ Head $tud and Nut NT CS 6.5 l BG1 B1. 8 RC / Reactor Vesset RC T1 RH 0056 Head Stud and Nut UT l CS 6.5 BG1 St. 8 RC /Reactorvessset RC T1 RN 0056 Head Stud and Nut hi, C$ 6.5 BG1 B1. 8 RC / Reactor Vessel - RC T1 l Rh 0057 Head stud and Nut UT CS 6.5 BG1 B1. 8 RC /Seactor Vesset RC T1 RN 0057 Head stud and Nut MT CS 6.5 l l l BG1 B1. 8 RC / Reactor Vesset RC T1 RN 0058 Head Stud and Nut UT CS 6.5 l l l BG1

81. 8 RC / Reactor vesset - RC T1 RM 0058
Head Stud and Nut MT CS 6.5 BG1
81. 8 RC / Reactor Vessel RC T1

. RM 0059 Head Stud and Nut UT CS 6.5 l. l BG1 B1. 8 RC / Reactor Vessel - RC T1 RN 0059 Head stud and Nut MT lCS ' 6.5 l 2-05/24/90 1 l-

  1. (

Nis 1 OWNER $ DATA REPORT FOR INSERVICE INSPECTION 1. 0WER: Netropoliten Edison Ccapeny, 2800 Pottsville Pike, Reading, Pennsylvente 2. PLANT: Three Mlle Island Nuclear Generating Station, Route 441 South, Middletown, Pennsylvania j 3. PLANT UNIT 1 4. OWNER CERTIFICAfl0N OF AUTHORIZAfl0N (if rowtred): None 5. C0184ERCIAL SERVICE DATE: 09/02/74 l 6. Nail 0NAL 30ARD NUMRER FOR UNIT: Reector Vessel N*109 4 OUTAGE 8R TABLE 1 ) i 1 ASME AseC NDE J CAT. ITEM No SYSTEM / COMPONENT COMPONENT ID DEstRIPTION METH MAT DIA REMARKS l ......o................................................................................... BG1 B1.8l RC / Reactor Vessel RC T1 RH+0060 Head Stud and Nut UT Cs 6.5 i BG1 B1. 8 RC / Reactor vessel RC Ti RM 0060 Head stud and Nut MT CS 6.5 BC1 B1. 9 RC / Reactor vessel PC T1 RN 0041F Flange Ligaments UT ' Cs ! 6.5 t i BG1 B1. 9 RC / Reactor Vessel RC 11 RM 0042F Flange Ligaments UT ' CS 6.5 BG1 B1. 9 RC /keector Vessel

  • RC T1 RN 0043F Flange Ligaments UT CS 6.5 B G*1 B1. 9 RC / Reactor vessel RC 11 RM 0044F flange Ligaments UT CS 6.5 BG1 B1. 9 kC / Reactor Vessel RC T1 RN 0045F Flange Ligaments UT CS 6.5 BG1 Bl. 9 RC / Reactor vessel RC T1 RM 0046F Flange Ligaments UT l CS 6.5 BG1
81. 9 RC / Reactor vessel RC 11 RH 0047F Flange Ligaments UT Cs 6.5 BG1 B1. 9 RC / Reactor Vessel RC T1 RN 0048F flange Ligaments UT l CS 6.5 l

l BG1 B1. 9 RC / Reactor Vessel

  • RC*T1 RM 0049F l Flange l'gaments UT CS 6.5 B G 1' B1. 9 RC / Reactor vessel RC T1 RH+0050F Flange Ligaments UT CS l 6.5 I4.5 BG1 B1. 9 RC / Reactor vessel RC T1 RN 0051F Flange Ligaments UT Cs B G-1 B1.' 9 RC / Reactor Vessel RC 11 RM 0052F

' Flange Ligamentss UT CS 6.5 l BG1 B1. 9 RC / Reactor Vessel - RC T1 RH*0053F Flange Ligaments UT CS ' 6.5 BG1 B1. 9 RC / Reactor vessel RC T1 RX 0054F Flange Ligaments UT ' CS 6.5 l BC1 B1. 9 RC / Reactor vessel Rc T1 RM 0055F Flange Ligaments UT ' CS 6.5 BG1 B1. 9 RC / Reactor Yessel RC T1 RM 0056F Flange Ligaments UT Cs l 6.5 BG1 B1. 9 RC / Reactor Vessel RC T1 RM 0057F Flange Ligaments UT Cs o.5 BG1 B1. 9 RC / Reactor vessel RC T1 RM 005BF Flange Ligaments UT l CS 6.5 3-05/24/90

i Nis 1 OWNERS DATA REPORT FOR INTRVICE INSPECTION J 1. CMNER: hetropoliten Edison company, 2000 Pottsvitte Pike, Readirg, Pennsylvania 2. PLANT: Three Mlle Island Nucteer Generating Statlon, j Route 441 South, Middletown, Ponnsylvente 3. PLANT UNIT: 1 4. OWNER CERTIFICAfl0N of AUTHORIZAfl0N (if regsf red): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NATIONAL BOAkD NUMBER FOR UNIT: Reactor Vesset N 109 OUTAGE 8R TABLE 1 1 ASME ASME NDE CAT ' ITEM NO SYSTEM / COMPONENT COMPONENT ID DESCRIPfl0N METH ' MAT DIA REMARKS ......e.......+................................+.............+......................+....+........+........+..................... BG1 St. 9 RC / Reactor Vessel

  • RC T1 RN 0059F Flange Ligaswnts UT CS 6.5 BG1 B1. V RC / Reactor vessel RC T1 RM 0060F FlanBe LIBaments UT ' CS 6.5 BG1 B1.10 RC /keector Vessel
  • KC T1 RM 0031W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor vessel RC T1 RM 0032W Spherical Washers VT. CS 6.5 BG1 B1.10 RC / Reactor vessel
  • Rc T1 RM 0033W

$@ erleat Washers VT CS 6.5 BG1 B1.10 RC / Reactor vessel. RC T1 RM 0034W-Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel RC T1 RM 0035W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel RC T1 l RM 0036W Spherical Washers VT. CS l 6.5 RM 003N Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel

  • RC T1 dG1 B1.10 RC / Reactor Yessel - RC T1 RM 0038W Spherical Washers VT CS 6.5 B G-1 81.10 RC / Reactor Vessel RC T1 RM 0039W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Yessel RC T1

. RM 0040W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel RC T1 RM 0041W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor vessel RC T1 RM 0042W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel - RC T1 RM 0043W Spherical Washers l VT CS 6.5 BG1 B1.10 l RC / Reactor Vesset RC T1 RM 0044W l Spherical Washers VT ; CS i 6.5 BG1 B1.10 RC / Reactor Vessel RC T1 RM 0045W Spherical Washers VT CS 6.5 l l BG1 B1.10 RC / Reactor vesset RC T1 RM 0046W Spherical Washers VT, CS l 6.5 BG1 B1.10 RC / Reactor Vesssel RC T1 RM-004N Spherical Washers VT CS 6.5 l BG1 B1.10 RC / Reactor Vessel - RC T1 RM 0048W l Spherical Washers VT CS 6.5 I 4-05/24/90 l

'.l i NIS 1 OWNERS DATA REPORT FD INSERVICE INSPECil0N 1. 0WNER: Metropoliten Edison comony, 2600 Pottsville Pike, Reading, Pennsylvente 2. PLANT: Three Mlle Island Nuclear Generating Station, Route 441 South, Middletown, Pennsylvente 3. PLANT UNIT: 1 4. OWNER CERTIFICATION OF AUTHORIZAfl0N (if regJired): None 5. ColetERCI AL SERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel N 109 i OUTAGE 8R TABLE 1 [ t ABME ASME l NDE l CAT ITEM N0 SYSTEM / COMPONENT COMPONENTIDl DESCRIPfl0N METH MAT DIA l REMARKS ......e.......+.................................+.............+......................+....+........+........+..................... BG1 B1.10 RC / Reactor Vessel RC T1 RH 0049W . Sphericot Washers VT CS 6.5 B-G 1 B1.10 RC / Reactor vesset RC fi RM 0050W Sphericot Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel RC T1 RM 0051W Spherical Washers VT CS 6.5 BG1 81.10 RC / Reactor Vessel RC 11 RM 0052W Spherical Washers VT CS 6.5 BG1 31.10 RC / Reactor vessel RC 11 RM 0053W Spherical Washers VT CS 6.5 BG1 B1.10 RC / Reactor Vessel RC fi RH 0054W Sphericot Washers VT CS 6.5 BG1 B1.10 RC /Reacter Vessel RC T1 RH 0055W Sphericot Washers VT CS 6.5 BG1 81.10 RC / Reactor Vesset RC T1 RM 0056W Spherical Washers VT CS 6.5 ) -BG1 B1.10 RC / Reactor vessel RC T1 RH 0057W Shperical Washers VT CS - 6.5 BG1 B1.10 RC / Reactor Vessel RC 11 RH 0058W Spherical Washers VT CS 6.5 B G 1-31.10 RC / Reactor vessel - RC T1 - RM 0059W Spherical Washers VT CS 6.5 RC1 B1.10 't RC / Reactor vessel RC T1 RM 0060W

Spherical Washers VT CS 6.5 BG2 B1.11 RC / Reactor vesset kC T1 CRDM Bolting, Flente Botting VT. CS/SS 1.0 See *.. 2.

B0 B1.18 RC / Reactor Yessel

  • RC T1 CRD 0073

' Base to Motor Tube UT SS/CS 4.2/5.8 Weld B0 51.18 RC / Reactor vessel RC T1 l CRD 0074 Motor Tube to UT SS/CS 14.2 Extension Weld -B0 B1.18 RC / Reactor vessel RC T1 CRD 0075 Extension to Cap Weld UT 4.2 B0 81.18 RC / Reactor vessel RC T1 ' RH 0074 Adapter to Flente UT SS 4.0 Weld l B0 B1.18 RC / Reactor vessel - RC T1 ' RM 0075 Bod / to Adapter Weld UT INC/SS 4.0 BF B2.4 RC /Pressuriter RC T2 PR 0009BM Safe End to Nortle UT CS/INC 5.12 Weld l BF B2.4 RC /Pressurfter - RC T2 PR 0021BM 1Nottle to safe End UT CS/S$ 11.5/11 l Weld 5-05/24/90

% je j l s Wil 1 OWNERS DATA REPORT FOR INSERVICE INSPECil0N 1. OWNER: Metropolitan Edison Company, 2800 Pottsville Pike, ReadinB, Pennsylvente 2. PLANY: Three Mlle 16tand Nuclear GeneratinB Station, Route 441 South, Middletown, Pennsylvania 3. PLANT UNIT 1 4 OWNER CERTIFICAi!ON OF AUTHORIZAil0W (if required): None 5. COMMERCIAL BERVICE DATE: 09/02/74 6. WAfl0NAL BOARD NUMBER FOR UNIT: Reactor Vsstel N 109 OUTAGE 8R FABLE 1 ABME ABME NDE CAT ITEM NO SYSTEM / COMPOWENT COMPONENT ID DESCRIPfl0N METH MAT DIA REMARKS ......o.......+.................................+.............+......................+... +,.......+.............................. BH B2.8 RC /Pressuriser RC T2 PR 0027WA Integral Attachment Mt CS 97 Weld BH B2.8 RC /Pressuriser PC-T2 PR 0028WA Integral Attachment MT CS 97 Weld BH B2.8 RC /Pressuriser RC 12 PR 0029WA Integral Attachment Mi CS 97 Weld BB B3.1 MU / Letdown Cooter MU C1B MU 1022L l Manifold Long Seam UT 3.75 Examined accessible Weld length only. BB B3.1 MU / Letdown Cooler MU C1A MU 1036L Manifold Long Seam UT ' SS 3.75 Examined accessible Weld Length only. BB B3.1 MU / Letdown Cooter MU CIA l MU 1037L Manifold Long Seam UT 3.75 Examined accessible Weld length only. BD B3.2 1C / Steam Generator

  • RC N 18 SG 0008N Wozzle to Lower Head UT CS 28 Weld and Inner Radius BD B3.2 RC / Steam Generator
  • RC N 1B SG-0009N Wozzle to Lower Head UT ' CS 28 Weld and Inner Radius BF B4. 1 DH /12" DH Orop Lire DN 0001BM Branch Safe End Weld !

UT CS/S$ 13.8/12 i BF B4. 1 Mu /2 1/2" W I Line to RC P1D MU 0901BM Velve to Safe End UT SS/INC. 2.5 Exam on safe end side Loop Weld i only. BF B4. 1 Mu /2 1/2" HPI Line to RC P1D

MU 0901BM l valve to Safe End PT

$$/INC l2.5 Loop Weld BF B4. 1 Mu /2 1/2" HPl Line to RC PIC MU 0903BM Valve to Safe End PT INC/S$ 2.5 l Loop Weld BF B4. 1 MU /21/2" HPl Line to RC P1C MU 0903BM valve to Safe End UT $$/INC 2.5 Exam on safe etid side Loop WeId onty. BF B4. 1 RC /28 Inch Line - RC H 1B to RC-0078BM Plpe to Pipe Weld PT CS/S$ 28 RC P1C l BF B4. 1 RC /28 Inch Line

  • RC H 1B to RC 0078BM Pipe to Pipe Weld UT CS/SS 28 RC P1C BF B4. 1 RC /28 Inch Line RC N 1B to RC 0097BM Pipe to Pipe Weld PT CS/S$
28 RC P1D l

l BF B4. 1 RC /28 Inch Line

  • RC N 1B to RC 0097BM Pipe to F:pe Weld l

UT CS/$$ 28 RC P1D BF B4. 1 RC /1 1/2" RC P1A Loop Drain RC-0173BM l Safe End to Elbow PT lWC/SS 1.5 lWeld j BF B4. 1 RC /1 1/2" RC P1A Loop Drain RC 0173BM Safe End to Elbow RT INC/S$ 1.5 Weld B J: '84. 5 DH /1C" Line DH*V22B to CFS DH*0020 valve to Tee Weld UT 10 l 6-05/24/90

' o,. .'/ i Nit 1 OWNER $ DATA REPORT FOR IN2VICE INSPECTION 1. OWNER: Metropoliten Edisor. Company, 2000 Pottsvitte i Pike, ReadinB, Pennsylvente 2. PLANT: Three Mlle Island Nuclear GeneratinB Stetton, Route 441 South, Middletsen, Pennsylvente 3. PLANT UNIT: 1 4. OWNER CERTIFICATION OF AUTHORI2Afl0W (if required): None 5. Co mERCIAL SERVICE DATE: 09/02/74 6. NATIONAL 90ARD WUMBER FOR UNIT: Reactor Veeset W 109 CUTAGE 8R TABLE 1 ABME ACME NDE CAT ITEM N0 SYSTEM / COMPONENT COMPONENT ID DESCRIPil0N METH MAT DIA REMARKS ......e.......+.................................+.............+......................+.... +...................................... BJ

64. 5 W /21/2" Line to MU Cit MU 0017 Elbow to Pipe Weld UT SS 2.5 BJ H.5 MU /21/2" HPI Line to RC* PIA MU 0131 Pipe to Velve Weld UT SS 2.5 Loop i

8J

84. 5 Mu /2 1/2a HP! Line to RC P1A MU 0132

' Elbow to Pipe Weld UT 2.5 Loup BJ B4. 5 MU /21/2" HP! Line to RC P1A MU 0133 Pipe to Elbow Weld UT SS 2.5 Loop 5J B4. 5 Mu /2 1/2" HPl Line to RC P1A MU 0134 , Pipe to Elbow Weld UT 2.5 Loop BJ

84. 5 Mu /2 1/2" HPI Line to RC P1A

. MU 0135 Elbow to Pipe Weld UT, SS 2.5 Loop 8J B4. 5 Mu /2 1/2" HPl Line to RC*P1A MU 0136 Pipe to Elbow Weld UT SS 2.5 Loop 8J B4. 5 Mu /2 1/2" HPI Line to RC P1A MU 0137 l Elbow to Pipe Weld UT 2.5 Loop 8J B4. 5 Mu /2 1/2" HPI Line to RC P1A MU 0138 Pipe to Elbow Weld UT 2.5 f Loop 8J B4. 5 Mu /21/2" HPI Line to RC P1A MU 0139

Elbow to Pipe Weld UT SS 2.5 Loop BJ B4. 5 Mu /2 1/2" HPI Line to RC PIA MU 0140 Elbow to Elbow Weld UT SS 2.5 Loop BJ
54. 5,

Mu /2 1/2a Line FROM MU C1B MU 0213 Pipe to Elbow Weld UT SS

2.5 l

8J E4. 5 MU /2 1/2" Line fran MU CIA MU 0217 Elbow to Velve Veld UT 2.5 i BJ

84. 5 MU /21/2" Line from MU-C1B IMU 0237 Pipe to Elbow Weld UT lSS

. 2.5 1 1 I i -BJ H.5 Mu /2 1/2" Line from MU C1B MU-0238 l Eltow to Pipe Weld UT SS ' 2.5 BJ B4. 5 Mu /2 1/2" HPI Line to RC PIA MU 0950 Pipe to Elbow Weld UT SS 2.5 l tooP BJ H.5 MU /21/2" HP! Line to RC P1A MU 0951 Elbow to Pipe Weld UT SS 2.5 i -Loop BJ

84. 5 RC /28" Line - RC N 1A to RC 0042

' Pipe to Pipe Weld UT CS 28 j RC PIB BJ-H.5 RC /28" Line RC N 1A to RC 0044 ' Pipe to Ptap Weld UT SS 31 RC PIB p. 6J lB4.5 Rr. /36" Line

  • RC T1 to RC H 1B RC 0066 Elbow to Pipe Weld UT CS

' 36 l l 7-05/24/90 l l n

i l oj a: /. ) 1 Nis.1 OWNERS DATA REPORT C INSERVICE INSPECTION 1. 0WNER: Metropolitan Edison Company, 2800 Pe'.tsville Pike, ReadinB, Pennsylvente 2. PLANT: Three Mlle island Nuclear t,eneratinB Stetton, Route 441 South, Middletown, Pennsylvente 3. PLANT UNIT: 1 4. OWNER CERTIFICATION OF AUTNORIZATION (if regelred): None j 5. ComeERCIAL BERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT Reactor vessel N 109 { OUTAGE 8R I TABLE 1 l ASME AS8( NDE t CAT : ITEM NO SYSTEM / COMPONENT COMPONENT ID DESCRIPfl0N METH MAT DIA REMARKS .............................................. +............. +...................... +.... +........ +........ +..................... f BJ B4. 5 RC /36" Line RC T1 to AC N 1B RC 0067 Pipe to Nottle Weld UT CS 36 BJ B4. 5 RC /28" Line

  • RC H 1A to RC*0120

, Pipe to Pipe Weld UT SS 31 RC P1B BJ B4. 5 kC /28" Line RC H 1A to RC 0121 Pipe to Pipe Weld UT SS 28 RC P1B l BJ B4, 5 RC /28" Line RC H 1A to RC 0131 Pipe to Pipe Weld UT : CS 28 RC P1B BJ B4.' 5 RC /36" Line RC T1 to RC N it RC 0220L Outside Radius Long UT CS 36 Elbow Weld BJ B4. 5 RC /36* Line RC T1 to RC N 1B RC 0221L Inside kedius Long UT CS 36 Elbow Weld ) i BJ B4. 5 RL '21/2" Pressurl er Relief RC 0275 Flange to Velve Weld UT SS 2.5 B J' B4. 5 RC /2 1/2" Pressurl er Spray $P 0001 Nottle to Pipe Weld UT SS 2.5 Line l BJ B4. 5 RC /2 1/2" Pressuriser Spray ! sP 0003 Elbow to Pipe Weld UT SS 2.5 Line BJ B4. 5 wC /4" Pressuriter Spray Line SP 0070 Elbow to Pipe Weld UT SS 4.0 BJ B4.8l MV /1 1/2" Seal Injection Line MU 0614s Elbow to Pipe Weld PT 1.5 to RC P1A t BJ B4. 8 MV /1 1/2" Seal injection Line MU 06578 Pipe to Elbow Weld PT 1.5 l to RC PID BJ B4. 8 Mu /1 1/2" Seal Injection MU 0748S ' Valve to Pipe Weld PT l 1.5 Header BJ B4. 8 Mu /i 1/2" Seal Injectior. Line MU 07718 Reducer to Pipe Weld PT l SS 1.5 to RC PID l l t BJ B4. 8 MV /2" Seal Injection Heador

MU 0796S Pipe to Coupling Weld PT, $S 2.0 BJ B4. 8 MU /2" Seal Injection Header MU 0797S Coupling to Pipe Weld PT ' $$

2.0 1 t BJ B4. 8 MV /2" Seal Injection Header MU 0798S Pipe to Eltow Weld PT SS 12.0 BJ B4. 8 Mu /2" Seal Injection Header MU 0799S Elbow to Pipe Weld PT SS 2.0 BJ B4. 8 Mu /2" Seal Injection Header MU 0800$ Pipe to Elbow Weld PT SS 2.0 l BJ-B4. 8 MV /2" Seal Injection Header MU 08018 ' Elbow to Pipe Weld PT SS 2.0 {' I 8-05/24/90 1 -4

c o,* =, / NIS 1 OWNERS DATA REPORT FOR INSERVICE INSPECTION 1 1. 0WNER: Metropolitan Edison Company, 2800 Pottsville Pike, leadine, Pennsylvents 2. PLANT: Thres Mlle Island Nuclear Generating Station, ) Rcute 441 South, Middletoim, Pennsylvante 3. PLANT UNIT 1 4. OWNER CERTIFICATION OF AUTHORIZATION (if rew ired): None j 5. ComERCIAL SERYlCE DATE: 09/02/74 6. NATIONAL 00ARD Nu dtR FOR UNIT: Retctor YeaseL W 109 ] l OUTAGE OR Tastt 1 .A9ME ASME l NDE CAT ITEMN0l SYSTEM / COMPONENT COMPONENT 10 DESCRIPfl0N METH MAT DIA REMARKS ......e.......+...................................................................... BJ B4. 8 Mu /2" Seal Injection Hender MU 0802S Pipe to Elbow Weld PT SS 2.0 1 1 B+J H. 8 Mu/11/2"SealInjectionLine W 08298 fee to Pipe Weld PT SS 1.5 to RC P1D r BJ H. S W /11/2" 4est injection Line itJ oc30S fee to Reducer Weld PT SS 1.5 .to.RC P1D FJ. j H. 8 W /1 1/2" Seal injection Line W 0831$ Pipe to Tee Weld PT SS b5 to RC P1D 0J.

84. 8 Mu /1 1/2" Seal injection Line W 0832" Co @ ling to Pipe Weld PT 1.5 to RC P1D BJ l D4. 8 Mu/11/2"SealInjectionLine W 08336

' Pipe to Co@ ling Weld PT SS 1.5 to RC P1D BJ_

64. 8 W /1 1/2" Seat injection Line MU 0834S Elbow to Pipe Weld PT SS 1.5 to RC P1D BJ S4. 8 Mu /1 1/2" Seat injection Line MU 08355 Pipe to Elbow Weld PT SS 1.5 to RC P1D BJ H. 8 W /1 1/2* Seal Injection Line MU 0836S
Elbow to Pipe Weld PT ' $$

' 1.5 to RC P1D RJ B4. 8 Mu /1 1/2" Seal I:Jection Line MU 08375 Pipe to Elbow Weld PT 1.5 i to P1D tJ' l B4. 8 MU /1 1/2" Seal injection Line MU 08386 Elbow to Pipe Weld PT SS 1.5 to RC P1D 8J

84. 8 Mu/11/2"SealInjectionLine MU 0830s

. Pipe to Elbow Weld PT 1.5 l' to RC P1D lI ' 8+J B4. 8 Mu/11/2"SealinjectionLine MU 0840$ Elbow to Pipe Weld PT SS 1.5 to RC P1D -l l L BJ B4. 8 Mu /1 1/2" Seal Injection Line W 08415 Pipe to Elbow Weld PT 1.5 l: to RC P1D-I'J B4. 8 MU /1 1/2" Seal Injection Line W 08425 Elbow to Pipe Weld PT . 1.5 l. to RC P1D 5J B4. 8 W /1 1/2" Seat injection Line MU 0843S Pipe to Elbow Weld PT ' $$ ' 1.5 to RC P1D B J-

64. 8 W /1 1/2' Seal Injection Line MU 0844S Elbow to Pipe Weld PT SS 1.5

(. to RC-P1D 8J B4. 8 Mu /1 1/2" Seat injection Line MU 0845$ ' Pipe to Elbow Weld PT SS 1.5 to RC PID BJ H.8 Mu /1 1/2" Seal Injection Line MU 08468 Velve to Pipe Weld PT SS 1.5 to RC P1D BJ B4. 8 W /1 1/2" Seat injection Line MU 08475 Redcer to Valve Weld PT SS 1.5 to RC PID l 9-05/24/90 y e-7 y- -m

i; NIS 1 OWNERS DATA CPORT FOR INBERVICE INSPECTION 1. 0WNER: Metropolitan Edison Com, 2600 Pottsvllte Pike, Reading, Pomsylvania 2. PLANT: Three Mlle Island Nuclear Generating Station, Route 441 South, Middletown, Pennsylvania 3. PLANT UNIT: 1 c. (NNER CERTIFICAfl0N OF AUTHORIZATION (if row ired): None ). 2 V RCIAL SERVICE DATE: 09/02/74 i p.0NALBOARDNunBERFORUNIT: Reactor Vessel N*109 OUTAQE SR TABLE 1 g } i ASMElASME NDE l CAT llTEM NO STSTEM / COMPONENT COMPONENT ID DESCRIPTION METH MAT l DIA REMARKS i ......e.......+.................................+.............+...........................+................+..................... BJ B4. 8 MU /11/2" Seat injection Line ' MU 0848$ Flow Element to PT SS 1.5 to RC*P1D keducer Weld BJ B4. 8 MU /1 1/28 Seal injection Line MU 08495 Elbow to flow element PT SS 1.5 to RC PID Weld BJ ~ B4. 8 Mu /1 1/2" Seal injection Line MU 0850$ Pipe to Elbow Weld PT ' SS 1.5 to RC P1D BJ B4. 8 MV /1 1/2" Seat injection line MU 00518 Elbow to Plpe Weld PT SS 1.5 to RC P10 BJ B4. 8 MV /11/2" Seal Injection Line MU 08528 Pipe to Elbow Weld PT SS 1.$ to RC P1D BK1 B4. 9 CF /14" B Line to Reactor CF 0051WA . Integral Attachment PT 14 See Table 2. Vessel Weld 'B K 1 B4. 9 CF /14" B Line to Reactor CF 0052WA Integral Attachment PT SS

14 See Table 2.

Vessel Weld BK1 B4. 9 CF /14" B Line to Reactor CF 0053WA Integral Attachment PT SS 14 Vessel ' Weld BK1 B4. 9 CF /14" 5 Line to Reactor CF 0054WA Integral Attachment PT 14 Vessel Weld i'.BK2 B4.10 CF / Piping Support CF 007 Snubber VT WA 14 See Table 2. BK2 B4.10 CF / Piping Steport

CF 008 Srm&ber VT NA 14 I

BK2 B4.10 CF / Piping Support ! CF 013 Verlable VT NA 14 BK2 B4.10 DH / Piping Support DM 001 Verlable VT NA 12 BK2 B4.10 DN / Piping Steport DM 5 l Snubber VT NA 12 BK2 B4.10 DH / Piping Support DH 6 Anchor VT NA 12 BK2 B4.10 MV / Piping Support MU 092 1 U Bolt VT NA 1.5 I BK2 B4.10 MU / Piping Steport seJ 099 8 U Bolt VT NA 1.5 BK2 B4.10 Mu / Piping Support MU 111 16 U Bolt VT NA l 1.5 g' l BK2 B4.10 Mu / Piping Stpport- . MU 136 1 nriable l VT NA 1.5 See Table 2.. BK2 B4.10 Mu / Piping Stpport MU 136 2 Verlebte YT NA 1.5 See Table 2. 10-05/24/90 1

L l e ,a NIS 1 thalER$ DATA REP 0Itf FOR INSERVICE INSPECTION 1. OWuft: Metropolitan Edison Company, 2400 Pottsville Pike, Reading, Pennsylvanla 2. PLANT: Three Mlle Island Nuclear Generatirg Station, toute 441 South, Middletown, Pennsylvania 3. PLANT UNIT 1 4. OWNER CERTIFICATION OF AUTie0RIZAfl0W (if rogstrod): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NAfl0NAL BOARD NUMBER FOR UNIT Reactor Vessel N 109 OUTAGE 8R TABLE 1 s ASME AtME NDE CAT ITEM NO STSTEM / COMPONENT COMPONENT ID DESCRIPTION METH MAT DIA REMARKS ......e......................................................................................................................... BK2 B4.10 Mu /Pipiry tiupport MU 136 3 Verfable VT NA 1.5 ' See Table 2. BK2 84.10 Mu / Piping 14pport MU 136 4 ' U Bott VT l NA t.5 l BK2 94.10 Mu / Piping $ w rt 'MU 136 5 U Bolt VT NA 1.5 B K+2 B4.10 Mu / Piping Support MU 136 6 U Bott VT NA 1.5 See Table 2. B K+2 B4.10 Mu / Piping support MU 1371 U Bolt VT NA 1.5 , see Table 2. l BK2 B4.10 Mu / Piping Support MU 137 2 U Bolt VT NA 1.5 BK2 B4.10 MU / Piping Support MU 137 3 U Bolt VT NA 1.5 BK2 B4,10 MV / Piping Support MU 137 4 U Bolt VT NA 1.5 BK2 B4,10 Mu / Piping $ @ port MU 137 5 , U Bolt VT NA 1.5 l -BK2 B4.10 Mu / Piping Support MU 137 7 U-Bolt VT NA 1.5 I BK2 54.10 Mu / Piping Support MU 138 2 U Bolt VT NA 1.5 i BK2 B4.10 MU / Piping Support MU 138 3 U Bolt VT NA 1.5 BK2 B4.10 Mu / Piping Support MU+138 4 U Bolt VT NA 1.5 BK2 B4.10 Mu /Piplng $ @ port MU 139 1 U Bolt VT WA 1.5 BK2 B4.10 Mu / Piping $ gport MU 139 6 Variable VT NA 1.5 see Table 2. UK2 'B4.10 Mu / Piping Support MU 139 7 variable VT NA 1.5 See Table 2. BK2 B4.10 MU / Piping support MU 140 4 Varlebte VT NA 1.5 See Table 2. l BK2 B4.10 MU / Piping support MU 141 1 U Bott VT WA . 1.5 l BK2 84,10 Mu / Piping S@ port MU 141 2 U Bolt VT NA 1.5 BK2 B4.10 ' Mu / Piping Support MU 141 3 U Bolt VT WA 1.5 i 11 05/24/90 s

  • 4

.,e Wit 1 OWER$ DATA CiPORT FOR INSERVICE INSPECTION i 1 1. OWER: Metropoliten Edison Ctapany, 2800 Pottavllte Pike, Reading, Pennsylvente f 2. PLANT: Three Mlle Island Nucteer Generating Stetton, Route 441 South, Middletown, Pennsylvente 3. PLANT UNIT: 1 4. O WER CERTIFICATION OF AUTHOR 12Afl0N (if re w ired): None J 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NAT10kAL BOARD NUMBER FOR UNIT: Reactor Vessel N 109 CUTAGE BR TABLE 1 AIME ABME NDE CAT ITEM WO SYSTEM / COMPONENT COMPONENT ID DESCRIPfl0N METN MAT DIA REMARKS i ......o.........................................+.............+......................+.... +....................................... 6 B K 2 { B4.10 MV / Piping Support MU 141 4 l U-Bott VT NA 1.5 l BK2 B4.10 MU / Piping Support MU 141*5 U Bolt VT NA 1.5 l BK2 B4.10 Mu / Piping $ @ port MU 141 8 U Bolt VT NA 1.5 BK2 B4.10 l Mu / Piping Support MU 142 6 U Bolt VT NA 1.5 BK2 B4.10 MV /Plping S @ Port MU 143 1 U Bolt VT NA 1.5 j BK2 B4.10 Mu / Piping Support , W 144 02 U Bolt l VT NA 1.5 BK2 B4.10 MJ / Piping Support MU 144 03 U Bott VT NA 1.5 BK2 B4.10 Mu / Piping Support MU 144 05 U Bolt VT NA 1.5 BK2 B4.10 Mu / Piping Support MU 144 06 U Bolt VT NA 1.5 BK2 B4.10 MU / Piping Support MU 144 07 U Bolt VT NA 1.5 BK2 54.10 MU / Piping $@ port MU 144 08 U Bott VT NA 1.5 t BK2 B4.10 MV /Plping Support MU 144 09 U Bolt VT-NA 1.5 B K 2' B4.10 MV / Piping Support MU 144 10 U Bolt VT NA 1.5 t l BK2 B4.10 Mu / Piping support MU 145 1

U Bolt VT NA 1.5 BK2 B4.10 Mu / Piping Support MU 145 2 U Bolt VT NA 1.5 BK2 84.10 MU / Piping $@ port MU 146 1 U Bolt VT NA 1.5 B

BK2 B4.10 Mu /Plping $@ port MU 146 2

Verlebte VT NA 1.5 BK2 B4.10 Mu / Piping Support MU 146 3 U Bolt VT WA 1.5 t

l I BK2 B4.10 MU / Piping S@ port MU 146 4 U Bolt VT NA 1.5 See Table 2. B-K 2 B4.10 MU / Piping Support MU 148-03 U Bott VT. NA 1.5 12-05/24/90 i l 1

e,' i NIS*1 OWNERC DATA ktPCaf FC IN$ttVICE INSPECTION 11 OWNER: Metromilitan Edison compeny, 2500 Pottsville Pikei Reading, Pennsylvente 2. PLANT: Three pile Island kelaar Generating Station, Route 441 South, Middletoem, Pennsylvents 3. PLANT UNIT: 1 4 OWNER CERTIFICAfl0N OF AUTHORIZATION (if required): None 5. CGestRCIAL $F.RVICE Daft: 09/02/74 6. NATIONAL BOARD NUMBER FDP. UNIT: Reactor Vessel N 109 OUTAct BR TABLE 1 i ABME ASME NDE CAf litM No ST$ TEM / COMPONENT COMPONENT 10 DESCRIPfl0N METN MAT DIA REMAkKS ......e.........................................+.............+......................+....+........+........+..................... BK2 H.10 MU / Piping Support m 148 04 U Bolt VT ' NA . 1.5 See Table 2. BK2 B4.10 MU / Piping Su mort MU 148 05 U Bolt VT NA 1.5 BK2 H.10 W / Piping $wrt ' MU 148 11 U Bolt VT NA 1.5 B K*2 H.10 MV / Piping Support MU 148 12 U Bolt VT NA 1.5 BK2 B4.10 MV / Piping Support MU 148 13 U Bolt VT NA 1.5 B K+2 H.10 Mu / Piping Support ' MU+148 14 U Bolt VT NA

1.5 BK2 B4.10 Mu / Piping Support MU 148 15 U Bolt VT NA 1.5 BK2 H.10 MV / Piping $g port MU 149 01 U Bolt VT NA

' 2 BK2 54.10 Mu / Piping $g port MU 149 02 U Bolt VT WA 2 BK2 B4.10 MV / Piping Support MU 149 03 U Bolt VT NA 2 I B K*2 B4.10 MU / Piping S p rt MU 149 04 U Bolt VT N 2 BK2 H.10 Mu / Piping support ' MU 149 05 U Bolt VT NA . 2 See Table 2. BK2 54.10 Mu / Piping support ' MU 149 06 U Bolt VT NA 2 BK2 B4.10 MV / Piping Support MU 149-07 U Bolt VT NA 2 BK2 B4.10 MV / Piping Support MU 149 08 l'# Bolt VT NA 2 l BK2 B4.10 Mu / Piping support MU 149 09 U Bolt VT NA

2 BK2 B4.10 MV / Piping Support MU 149 10 U Bolt VT - NA 2

See Table 2. BK2 B4.10 MV / Piping $ w port MU 149 11 U Bolt VT NA 2 BK2 B4.10 Mu / Piping Support MU 149 12 U Bolt VT NA 2 BK2 B4.10 Mu / Piping Sg port MU 149 13 U Bolt VT lNA 2 l 1 13-05/24/90 l ~

t l' 1 a j. -., ' { WIS*1 OWNERS DATA REPORT FD INSERVICE INSPECTION 1. OWNER: Metropoliten Edleon Company, 2800 Pottsvltte Pike, Reading, Pennsylvenle 2. PLANT: Three Mlle Island Nucteer Generating Station, Route 441 South, Middletown, Pennsylvente 3. PLANT UNIT 1 4. OWNER CERTIFICAfl0N OF AUTHOR 12Afl0N (If rosaired): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel N 109 OUTAGE BR TABLE 1 - ABME ASME NDE CAT ITEM NO SYSTEM / COMPONENT COMPONENT 10 DESCRIPfl0N METH MAT DIA REMARKS .............. +................................. +................................................ +........ +..................... BK2 B4.10 W / Piping S@ port MU 149 14 U Bolt VT NA 2 BK2 84.10 Mu / Piping $@ port MU 149 15 l U Bolt VT NA 2 See Table 2. dK2 84.10 W / Piping Suport MUH 222 Verlebte VT NA 2.5 See Table 2. BK2 B4.10 Mu / Piping Support MUH 241 Verlebte VT ' NA 2.5 BK2 84,10 MU / Piping Support MUH 245 Verlebte VT NA 2.5 l l BK2 B4.10 Mu / Piping Support MUH 246 Verlebte VT NA 2.5 See Tebte 2. l BK2 B4.10 MV / Piping Support MUH 248 ' Verlebte VT NA 2.5 BK2 B4.10 Mu / Piping Support MUH 249 Verlebte VT NA 2.5 See Table 2. BK2 84.10 MU / Piping S@ port MUH 291 U Bolt VT NA 2 l-l BK2 84.10 RC / Piping $@ Port RC 05 l $rv.hber VT NA , 1.5 BK2l B4.10 RC / Piping $@ port RC 12 1 Sndber VT NA 2.5 See Table 2. t BK2 B4.10 RC / Piping $@ port RC 14 ' Sns ber VT NA 2.5 r l 'BK2 B4.10 RC / Piping Support RC 15 Snubber VT NA 2.5 i l-l BK2 84.10 RC / Piping $@ port RC 16 Snubber VT NA 2.5 I BK2 B4.10 ' RC / Piping Support RC 34 2 'U Bolt VT WA 2 See Table 2. BK2 84.10 RC / Piping Support RC 34 3 U Bott VT WA 2 See Table 2. BK2 B4.10 RC / Piping Support . RC 35 1 U-Bolt VT WA 2 _B-K 2 B4.10 RC / Piping $ @ port RC 35 2 U Bolt YT NA 2 See Table 2. I l l-l B K-2 84.10 AC / Piping Support RC 35 3 U Bolt VT NA 2 See Table 2. l BK2 B4.10 MU / Piping Support RSH 466 U Bolt VT NA 1.5 I 14-05/24/90 l l i

6 l..ej ' + Nis 1 obr 6ERS DATA C' PORT FOR INSERVICE INSPECTION i 1. OWNER: Netropolitan Edloon Company, 2800 Pottaville Pike, Reading, Pennsylvania 2. PLANT: Three Mlle latend Nuclear Generating Station, Route 441 South, Middletown, Pennaytvania ( 3. PLANT UNIT: 1 4. OWNER CERTIFICAfl0N OF AUTHORIZAfl0N (if required): None 1 5. CossiERCIAL SERVICE DATE: 09/02/74 6. NAT10NAL BOARD NUMBER FOR UNIT: Reactor Yea 6el N 109 aufAGE 8R TABLE 1 ABME ABME NDE i CAT ITEM WO SYSTEM / CtMPONENT COMPONENT 10 DESCRIPfl0N METH MAT DIA REMARKS ................................................e.............+......................+.... e.......................................

B G 2

! B4.12 W /1 1/2" Seat Injection Line l Flange at Flange Botting VT CS/S$ 1.12 to RC Pic jMU 628 8 629 BG2 B4.12 Mu /1 1/2" Seal Injection Line Flange et Flange Botting VT CS/SS 1.12 to RC P10 MU 655 8 656 BG2 B4.12 Mu /1 1/28 Seat injection Line RC Pic Flange Botting VT CS/S$ ' t.12 to RC Pic Connection BG2 B4.12 Mu /1 1/2" Seal Injection Line RC P10 Flange Bolting VT CS/SS ' 1.12 to RC PiD Connection BG1 B5.3 RC / Reactor Cootent Po p - RCPc 001MF F ; Bolting VT CS/85 4.5 Examined in place. RC P1C BG1 B5.3 ' RC / Reactor Coolant Pwp - RCPc 002MF F Botting VT CS/S$ 4.5 Examined in place. RC P1C BG1 B5.3 RC / Reactor Coolant Pw p - RCPc 003MF F Botting VT CS/SS 4.5 Examined in place. RC P1C BG1 B5.3 RC / Reactor Coolant Pw p - RCPc 004MF F Botting VT CS/S$ 4.5 Examined in place. RC P1C BG1 B5.3 RC / Reactor Coolant Pwp - l RCPc 005MF F Botting VT CS/S$ 4.5 Examined in place. RC Pic BG1 05.3. ' RC / Reactor Cootant Puup

  • RCPc 006MF F Bolting VT CS/S$

4.5 Examined in place. RC PIC BG1 B5.3 RC / Reactor Cootent Pwp - RCPc 007MF F Bolting VT CS/S$ 4.5 Examined In place. RC Pic BG1 85.3 RC / Reactor Coolant Pw p

  • RCPc 008MF F Bolting VT CS/S$

4.5 Examined in place. RC PIC BG1 B5.3 RC / Reactor Coolant Pw p - RCPc 009MF F : Solting VT CS/SS 4.5 Examined in place. RC P1C S01 95.3 RC / Reactor Coolant Pw p - RCPc 010MF F Solting VT CS/SS 4.5 Examined in place. RC *1C J B G 95.3 RC / Reactor Coolant Pw p

  • RCPc 011NF F Botting VT CS/S$

4.5 l Examined in place. RC Pic BG1 B5.3 RC / Reactor Coolant Pump - RCPc 012MF F Botting VT CS/SS 4.5 Examined in place. RC P1C BG1lB5.3 RC / Reactor Coolant Pw p - RCPc 013MF F Botting V1 CS/S$ 4.5 Examined in place. RC Pic BG1-B5.3 RC / Reactor Coolant Puip - RCPc 014MF F Botting VT CS/S$ 4.5 Examined in place. RC PIC BG1 85.3 RC / Reactor Coolant Pwp

  • RCPc 015MF F Bolting VT CS/SS 4.5 Examined in place.

RC P1C l BG1 B5.3 RC / Reactor Coolant Pump - RCPc 016MF F Bolting VT CS/S$ 4.5 Examined in place. RC P1C 15 05/24/90 i 1

.:i Nis 1 OWNERS DATA REPORT FOR INSERVICE INSPECTION 1. 0WNER: Metropol(ten Edison Company, 2600 Pottsville Pike, Reading, Pennsylvania 2. PLANT: Three Mlle Island Nuclear Generatlng Station, toute 441 South, Middletown, Pemsylvania 3. PLANT UNIT: 1 4 0WNER CERTIFICATION OF AUTHORIZATION (if regelred): None 5. Co mERCIAL SERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel N*109 CUTAGE 8A TABLE 1 AtME ASME lNDE CAT ITEM NO SYSTEM / COMPONENT COMPONENT ID DESCRIPfl0N lMETH MAT DIA REMARKS i ...... +....... +................................. +............. +...................... +.... +........ +........ +..................... BG1 b5.3 RC / Reactor Coolant Puy

  • RCPc 017MF F tolting VT CS/S$

4.5 Examired in place. RC PIC 0G1 B5.3 RC / Reactor Coolant PW9

  • RCPc 018MF F tolting VT CS/S$

4.5 . Examined in place. RC PIC BG1 85.3 RC / Reactor Coolant Pusp - RCPc 019MF F tolting YT CS/S$ 4.5 Examined in place. RC PIC tG1 85.3 RC / Reactor Coolant Puer - RCPc 020MF F tolting VT CS/S$ 4.5 . Examined in place. RC PIC 4G1 85.3 l RC / Reactor Coolant Pump

  • RCPc 021MF F tolting VT CS/S$

4.5 Examined in place. RC PIC tG1 85.3 RC / Reactor Coolant Puip. RCPc 022MF F tolting VT CS/S$ 4.5 Examined in place. RC PIC l BC1 85.3 RC / Reactor Coolant Pump - RCPc 023MF F tolting VT CS/SS 4.5 Examired in place. RC Pic tG1 85.3 RC / Reactor Coolant Punp - RCPc 024MF F tolting VT CS/SS 4.5 l Examined in place. RC Pic tG1 85.3 ! RC / Reactor Coolant Puup

  • RCPd 001MF*F botting VT CS/SS 4.5 Examined in place.

RC P1D tG1 85.3 RC / Reactor Coolant Punp - RCPd 002MF F tolting YT CS/S$ 4.5 Examined in place. l RC PID tC1 85.3 RC / Reactor Coolant Puip

  • RCPd003NFFl Botting VT CS/S$

4.5 l Examined In place. RC P1D Obstruction. BG1 b5.3 RC / Reactor Coolant Puip - RCPd 004MF F tolting VT CS/SS 4.5 Examined in place. RC P1D Obstruction. BG1 85.3 RC / Reactor Coolant Punp * . RCPd 005MF F Solting YT CS/S$ 4.5 Examined in place. .C P1D tG1 85.3 RC /Reactw-Coolant Pung - RCPd 006MF F totting VT, CS/S$ 4.5 Examined in place. RC P1D tG1 85.3 RC / Reactor Colant Punp

  • I RCPd 007MF F tolting VT CS/S$

4.5 Examined in place. RC P1D tC1 85.3 RC / Reactor Coolast Pump - RCPd 008MF F tolting VT. CS/S$ 4.5 . Examined in place. RC P1D - BG1 85.3 RC / Reactor Coolant Puup - . RCPd 009MF F tolting VT ' CS/S$ . 4.5 Examined in place. RC P1D 8G1 85.3 kC / Reactor Coolant Punp - RCPd 010MF F tolting VT CS/SS 4.5 ' Examined in place. RC PID 8G1 85.3 RC / Reactor Coolant Puip - RCPd 011MF F tolting VT CS/SS 4.5 Examined in place. RC P1D l tC1 85.3 RC / Reactor Coolant Puip - RCPd 012MF F tolting VT lCS/S$ l4.5 Examined in place. RC P1D l l l 16-05/24/90 l

e. ,8 i ult 1 CWNERS DATA REPORT FOR INSL'RVluf IIS.'ECTION i 1. OWNER: Metropolitan Edison Company, 2600 Pottsvillt Pike, Reading, Pomsylvania I 2. PLANT: Three Mlle Island Nuclear Generating Station, I toute 441 South, Middletown, Pomsylvania 3. PLANT UNIT: 1 ) 4. OWNER CERTIFICATION OF AUTHORIZATION (if regatrod): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NAfl0NAL BMkD NUMBER FOR UNIT: tienctor Vessel N 109 OUTAGE OR TABLE 1 ] l ASME ASME NDE l CAT ITEM NO STSTEM / COMPONENT COMPONENT ID DESCRIPil0N METH l MAT DIA REMARKS ...... +....... +................................. +............. +...................... +.... +........ +........ +..................... BG1 B5.3 RC / Reactor Coolant Pump - l RCPd-013MF F Botting VT ' CS/S$ 4.5 fxamined in place. RC P1D BG1 B5.3 RC / Reactor Coolant Pw p. RCPd 016MF F Bolting VT CS/S$ 4.5 Examined in place. J RC P1D BG1 B5.3 RC / Reactor Coolant Pwp. RCPd*015MF F Botting VT CS/S$ 4.5 l Examined in place. RC P1D BG1 B5.3 RC / Reactor Coolant Puup * ' RCPd 016MF F Botting VI l CS/S$ 4.5 Examined in piece. RC P1D BG1 B5.3 RC / Reactor Coolant Pw p

  • RCPd 017MF F Botting VT CS/S$

4.5 ' Examined in place. RC P1D BG1 B5.3 RC / Reactor Coolant Puup

  • RCPd 01BMF F Botting VT CS/S$

4.5 Examined in place. RC P1D B01 B5.3 RC / Reactor Cootent Puip - RCPd 019MF F Botting VT CS/SS 4.5 Examined in place. RC P1D B G.1 B5.3 RC / Reactor Coolant Puip

  • RCPd 020MF F l Botting VT CS/S$

4.5 Examined in place. RC P1D BG1 B5.3 RC / Reactor Coolant Pulp

  • RCPd*021MF F Botting VT CS/SS 4.5 Examined in place.

RC PID Obstruction. BC1 B5.3 RC / Reactor Coolant Punp - RCPd 022MF F Bolting VT CS/S$ . 4.5 ! Examined in place. RC PID l BG1l B5.3 i RC / Reactor Coolant Puip - l RCPd 023MF F Botting YT CS/SS , 4.5 Examined in ptoce. i RC P1D .,.BG1 B5.3 RC / Reactor Coolant Ptsp = RCPd 024MF F Bolting VT CS/S$ ! 4.5 l Examined in ptoce. RC P1D Bt1 B5.4 RC / Reactor Coolant Punp

  • RCM277WA Integret Attachment PT SS 28 RC P1A Weld BK2 B5.5 RC /Puup SLpport RC P10 10 Constant VT NA NA BK2 B5.5 RC /Puip Stpport RC P10 11 Constant VT. NA NA See Table 2.

B K+2 B5.5 RC /Puip Support RC P10 12 Ring VT NA NA e l BC 2 B6.7 CF /14" B Line to Reactor CF YOO4B valve Interior VT I SS ' 14 Vessel BG2 B6.9 CF /14" B Line to Reactor CF V004B Hinge Pin Retainer VT <2.0 Vessel Botts CD C1.4 MS / Steam Generator

  • RC H iB Lower Sec.

Bolting VT CS 1.25 Manway - C-D. C1.4 MS / Steam Generator

  • RC N 1B Lower Sec.

Botting UT CS 1.25 2 studs examined. Manway 17-05/24/90

1 e ' d..

e'*

4 Nis 1 OWNERS DATA REPORT FOR INSERVICE INSPECTION 1. OWNER: Metropolitan Edison Cogeny, 2000 Pottsville Pike, Reading, Pennsylvanle j 2. PLANT: Three Mlle Island Nuclear Generating Station. l Route 441 South, Middletown, Pennsylvania J 3. PLANT UNIT: 1 j 4 OWNER CERTIFICAfl0N OF AUTHORIZAfl0N (if required): None 5. C01stERCIAL BERVICE DATE: 09/02/74 6. NAfl0NAL 904RD WUMBER FOR UNIT: Reactor Vessel N 109 j i OUTAGE 8R TABLE 1 ] ASME ASME NDE . CAT ITEM NO SYSTEM / COMPONENT COMPONENT 10 DESCRIPil0N METH MAT DIA REMARKS ......e..............................................................................+.... CD C1.4 DH / Decay Heat Cooler

  • DH.CiB Primary

' Botting VT CS/SS 1.12 Flange CD C1.4 DM / Decay Heat Cooler DN C1A Primary Bottin0 VI CS/$$ 1.12 Flange CD C1.4 DH / Decay Heat Cooler

  • DM C1B Primary Bolting UT CS 1.12 4 stude examined.

Flange CD. C1.4 DH / Decay Heat Cooler

  • DN C1A Primary Bolting UT l CS 1.12 4 studs examined.

Flange 'CD C1.4 MS / Steam Generator RC N 1B Upper Sec. Bolting VT CS 1.25 Manway CD C1.4 MS / Steam Generator RC*H il Upper Sec. Botting UT, CS 1.25 2 studs examined. Manway CF' C2.1 DH /10" Line DM C1A to Reactor DM 0034 Pipe to Valve Weld UT SS 10 vessel -Cf C2.1 DH /14" Line to BS P1A DM 0100 Pipe to Reduca. Weld UT 14 CF C2.1 DH /14" B Line frca DM T1 DM 0156 valve to Pipe Weld UT ' SS 14 Cf C2.1-DM /14" Line to DH P1B DH 0181 Tee to Pipe Weld UT SS 14 CF. C2.1 DH /14" Line to DH PIB DH+0202 Elbow to Pipe Weld UT SS 14 CF C2.1 DH /6" Crostconnect DH Coolers DM 0288 l Pipe to Elbow Weld UT l SS 6.0 to RV l CF C2.1 DH /6" Crossconnect DH Coolers DH 0290 Pipe to Elbow Weld UT 6.0 to RV CF C2.1 DH /10" Line DH P1B to DM C1B DM-0337 Pipe to Elbow Weld UT SS 10 .C F C2.1 DH /10" Line DM C1B to Reactor DH 0376 Reducer to Elbow Weld UT 10 Vessset CF C2.1 DH /6" Crossconnect DH Coolers DH 0387 , Pipe to Elbow Weld UT, SS 6.0 to RV i CF C2.1 MV /6" B Make Up Header

MU 0960 Pipe to Elbow Weld UT ' $s 6.0 CF C2.1 MV /6" B Make Up Siender MU 0970 l Elbow to Pipe Weld HT 6.0 CF C2.1 MV /6" Lin Betw. W PIB 5 MU 0982

. Pipe to Valve Weld UT SS 6.0 l MU P1C CF C2.1 MV /6" MU P1A suction Line lMU1003 Elbow to Reducer Weld UT SS 6.0 1 18-05/24/90 1 i l l

f. '. t

,e - e Nit 1 OWNERS DATA REPORT FOR INSERVICE l:SPECTION 1. 0WWER: Metropolitan Edison Company, 2800 Pottsvllte Pike, Reading, Pennsylvania 2. PLANT Three Mlle Island Nuclear Generating Station, Route 441 South, Middletown, Pomsylvania 3. PLANT UNITS 1 4 OWNER CERTIFICAfl0N OF AUTHORIZAfl0N (if regulred): None 5. Co mERCIAL BERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT Reactor Vessel N 109 CUTAGE OR TABLE 1 AIME ABME NDE CAT ITEM N0 SYSTEM / COMPONENT COMPONENT 10 DESCRIPfl0N METH i NAT DIA REMARKS ......e.......+.................................+.............+......................+.... +........+........+..................... CG C2.1 AN /48" Line

  • Penetration 423 AH 0175 Penetration to Flange Mt CS 48 See Table 2.

Weld -CG C2.1 EF /6" EF Line to RC N 1B EF 0024 Elbow to Pipe Weld UT CS 6.0 CG C2.1 LF /6" EF Line to RC N 1A EF 0103 Venturl to Pipe Weld UT CS/SS 6.0 CG C2.1 EF /6" EF Line to RC N 1A EF 0121 Elbow to Pipe Weld UT CS 6.0 CC C2.1 EF /6" EF Line to RC N 1R EF 0151 Tee to Pipe Weld UT CS 6.0 CG C2.1 EF /6" EF Line to RC*H 1B EF 0167 Valve to Pipe Weld UT CS 6.0 CG C2.1 MS /24" C Line MS 0047 Nortte to Elbow Weld UT CS 24 C-G C2.3 MS /24" B Line to EF U 1 (8") MS 01948 Weld o let Branch MT CS 8.0 Weld CG C2.3 MS /24" C Line to EF U 1 (12") MS 02338 Weld o let Branch MT CS 8.0 Weld CD C2.4 DW /12" Line to DN PIB 12" Flange on Flange Bolting VT CS/SS 1.12 12" x 10" Red CD C2.4 DN /12" Line to DM PIB 12" Flange on Flange Bolting UT CS 1.12 2 studs examined. 12" x 10" Red CD C2.4 Ah /48" Line Penetration 423 AH V1C Flange Bolting VT CS 1.5 Purse Supply Comection l l CD C2.4 AH /48" Line Penetration 423 AH VIC Flange Bolting UT CS 1.5 5 bolts examined. Purse $@ pty . Connection CD C2.4 AM /48" Line Penetration 423 lAN V1D Flange Bolting l VT CS 1.5 Purse $@ pty ' Connection l CD C2.4 AN /48" Line Penetration 423 AN VID Flange Botting UT CS 1.5 5 bolts examined. l Purge $@ ply Connection l CD-C2.4 DH /16" Line to DH P1B to DN C1B Intet Flange Botting VT j CS/SS 1.25 l DN C1B Flange l CD C2.4 DH /16" Line to DH*P1B to DM C1B Inlet Flange Botting UT ' CS 1.25 2 studs examined, i DH.C1B Flange l . C-D : C2.4 DM /16" Line to DH C1B to DH C1B Outlet Flange Botting VT CS/S$ 1.25 l Reactor Vessel Flange l C-D C2.4 DH /16" Line to DH*C1B to DM C1B Outlet Flange Bolting UT CS 1.25 2 studs examined. Reactor Vessel i Flange CD= C2.4 ' MS /A Rellef Line lMSY017A Flange Botting VT CS 1.37 l 19-05/24/90

i . t,* Wis 1 OWNERS DATA C' PORT FOR IWBERVICE INSPECTION 1 1. OWNER: Metropolitan Edison Company, 2000 Pottsvitte Pike, Reading, Pennsylvania 2. PLANT: Three Mlle Island buclear Ge wrating Station, Route 441 South, Middletown, Pennsylvania 3. PLANT UNIT 1 4 0WNER CERTIFICAfl0N OF AUTMORIZAll0N (if re @lted): None 5. ColetERCIAL SERVICE DATE: 09/02/74 6. NATIONAL DOARD WUMN R FOR UNIT Reactor Vessel N 109 OUTAGE 8R TABLE 1 ASME ASMt WDE CAT ITEM N0 SYSTEM / COMPONENT COMPONENT ID, DESCRIPfl0N METH MAT D i.' REMARKS ......e.......................................................+......................+.... +........+........+..................... C D' C2.4 MS /s Relief Lirw MS V0178 Flange tolting Yi CS 1.37 CD C2.4 MS /6" C Rollef Line MS Y017C Flange Botting UT CS ' 1.37 2 stude examined. CD C2.4 MS /6" C Relief Line MS V017C Flange Botting VT CS 1.37 l CD C2.4 MS /6" D Relief Line MS V017D Flange Botting UT, CS 1.37 2 stude examined. CD C2.4 MS /6" D Relief Line MS V017D Flange Bolting lVT CS . 1.37 C D-C2.4 MS /A Relief Line MS V018A Flange Botting VT CS 1.37 t CD C2.4 MS /B Relief Line MS V0188 - Flange Botting VT CS 1.37 C D -' C2.4 MS /6" C Re'.lef Line MS V018C Flange Botting UT CS 1.37 2 studs examined. CD C2.4 MS /6" C Retlef Line MS V018C Flange lotting VT CS ' 1.37 l CD C2.4 MS /6" D Relief Line MS V018D Flange Botting UT CS 1.37 2 studs examined. L CD C2.4 MS /6" D Relief Line MS V018D Flange Botting VT CS 1.37 CD C2.4' MS /A Relief Line MS V019A Flange Botting VT CS 1.37 l 1 l -CD-C2.4 MS /t Relief Line MS V0198

Flange Botting VT CS 1.37 C0 C2.4 MS /6" C Relief Line MS V019C
flange Bolting l

UT CS 1.37 2 studs examined. CD C2.4 MS /6" C Relief Line MS V019C Flange Botting VT CS 1.37 l-CD C2.4 MS /6" D Relief Line l MS YO19D Flange Botting UT CS l 1.37 2 studs examined. CD C2.4 MS /6" D Relief Line MS V0190 Flange Botting VT CS 1.37 i CD C2.4 MS /A Relief Line l MS V020A Flange Botting VT CS 1.37 C D. C2.4 MS /B Rellef Line MS L'0B Flange Botting VT CS 1.37 'CD C2.4 MS /6" C Rellef Line MS V020C Flange Bolting UT CS l 1.37 2 studs examined. l 20-05/24/90

o

9,.

+ Wit i OWERS DATA REPORT FOR INSERVICE INSFECTION 1. OWNER: Metropolitan Edison Company, 2800 Pottsvitle Pike, Reading, Pennsylvania 2. PLANT: Three Mlle Istarst Nuclear Generating Station, Route 441 South, Middletoim, Pennsylvania 3. PLANT UNIT: 1 i 4 OWNER CERTIFICAfl0N OF AUTHOR 12Afl0N (if required): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. WAfl0NAL 90ARD NUMBER FOR UNIT: Reactor vessel N 109 OUTAGE 8R TABLE 1 A9ME ADME NDE CAT ITEM No SYSTEM / COMPONENT COMPONENT ID DESCRIPTION METH MAT DIA REMARKS 1 ...c..e.......+.................................+.............+......................+....+........+........+..................... CD C2.4 MS /6" C Relief Line MS V020C Flange Bolting VT CS 1.37 CD C2.4 MS /6" D Relief Line MS V0200 Flange Botting i UT CS 1.37 2 stude examined. \\ 1 CD C2.4 MS /? D Rollef Line MS YO200 Flange Bolting VT CS 1.37 See Table 2. CE1 C2.5 - AM /48" line a Penetration 423, AH 0019WA Integrat Attachment MT CS 48 See Table 2. Weld t CE1 C2.5 WM /14 Inch A Line to DH T1 DN 0018WA Integret Attachment PT SS . 14 l Weld CE1 C2.5 DN /14" B Line to DN T1 DN 0019WA Integret Attachment PT SS 14 ! See Table 2. Weld i CE1 C2.5 DH /10" Line DH C1A to Reactor DN 0104WA Integret Attachment PT SS 14 Vessel Weld C E*1 C2.5 DH /14" B Lir* to DM PIB DM 0112WA Integret Attachment PT 14 , Weld CE1 C2.5 DH /14" Line to DN P1A DM 0154WA Integral Attachment PT 12 Weld CE1 C2.5 DH /14" Line to DN P1A . DH 0155WA Integral Attachment PT ; $$ 12 Weld C-E*1 C2.5 DH /14" A Line to DN P1A DM 0163WA Integral Attachment PT ; $$ 14 Weld C E*1 C2.5 DH /14" A Line to DN PIA DN 0164WA !ntegret Attachment PT 14 Weld CE1 C2.5 DH /14" A Line to DN P1A DN-0165WA Integret Attachment PT 14 L Weld l CE1 C2.5 EF /6" EF Line to RC N 1A l EF 0133WA Integral Attachment MT l CS 6.0 Weld CE1 C2.5.I EF /6" EF Line to RC N 1A EF 0134WA l Integrat Attachment MT CS 6.0 { Weld CE1 C2.5 EF /6" EF Line to RC N 1A , EF 0135WA Integrat Attachment NT l CS 6.0 l Wetd C E*1 C2.5 EF /6" EF Line to RC H 1A EF 0136WA Integrat Attachment MT 1;CS 6.0 Weld CE1 C2.5 EF /6" EF Line to RC N 1A EF 0137WA Integrat Attachment MT CS 6.0 Weld CE1 C2.5 EF /6" EF Line to RC N 1A EF 0138WA l Integret Attachment MT CS 6.0 . Weld CE1 C2.5 EF /6" EF Line to RC N 1A EF 0139WA Integrat Attachment MT CS 6.0 Weld 21 05/24/90 I -,m

a......

' * $.. j j { 3 i NIS 1 OWNERS DATA REPORT FOR INMRVICE INSPECTION ,i q 1. 0WNER: Metropoliten Edism Company, 2800 Pottsville Pike, Reading, Pennsylvente-2 PLANT: Three Mlle talend Nuclear Generating Station, Route 441 South, Middletown, Penney lvente 3.= PLANT UNIT: 1 4 OWNER CERTIFICATION OF AUTHORIZATION (if required): Nong 5. ColetERCIAL SERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT Reactor vessel N 109 OUTAGE 8R TABLE 1 ASME ASME l l -lNDE CAT ITEM No SYSTEM / COMPONENT [ COMPONENT 10 DESCRIPTION lMETH MAT DIA ' REMARKS ......e.......+.................................+.............+......................+....+........+........+..................... CE1 C2.5 - EF /6" EF Line to RC H 1A EF 0140WA Integral Attachment MT CS 6.0 Weld C E*1 C2.5 FW /14" RH RC N-1A Header FW 0174WA Integral Attachment MT CS ' 14 Weld C E 1. C2.5 MU /6" B Make Up Header MU 0038WA Inte r.1 Attachment PT 6.0 Welo iCE1 C2.5 - MU /6" MU P1A Suction Line MU 0090WA Integral Attachment PT SS 6.0 Weld V -CE1 C2.5 Mu /6" Line Betw. MU P1A & MU 0747WA Integral Attachment PT SS 6.0 MU P1B Weld CE1 C2.5 MU /6" Line eetw. MU P1A & MU 0785WA Integral Attachment PT SS 6.0 MU-P1B Weld -CE1 C2.5 Mu /6" Line Betw. MU P1A & MU 0786WA Integral Attachment PT ! SS 6.0 MU-P1B Weld CE2 C2.6 CF / Piping Support CF 003 verlebte VT NA 14 'CE2 C2.6 CF / Piping Support CF 010 verlebte VT ' NA 14 Cr2 C2.6 DH / Piping Support DM*23 Snubber VT NA 10 l CE2 C2.6 'DH / Piping Support DH 24 Snubl.er VT NA 10 CE2 r2.6 DM / Piping S p ort DHH 116 Rigid VT: NA 10 l 'CE2 C2.6 DH / Piping Support-DHM 120 Verlebte 1 VT NA 10 -- C E 2 C2.6-l DH / Piping Support DHH 121 I verlebte VT lNA 10 CE2 C2.6.' DH / Piping Support DHH 132 Rigid VT NA 12 .CE2 C2.6-DH / Piping Support DHH 174 ' Anchor VT NA 12 l E C E 2 , C2.6 DH / Piping Support DHH 213 Guide VT WA 12 l CE2 C2.6 U / Piping Support EF 115A , Rigid VT WA 6 CE2 C2.0 EF / Piping $ @ port EF 118 Rlgid VT hA 6 See Table 2. 1 CE2 C2.6 FF / Piping L pport lEF128 l Rigid VT NA l6 {See Table 2. I i i I 22-05/24/90 .F

lii, ' ' A);. kf [,* 5 l' M. Nis 1 OWNERS DATA REPORT FOR INSERVICE INSPECTION 1. 0WNER: Metropoliten Edison Company, 2800 Pottsville Pike. Reading, Pennsylvente 2. PLANT: Three Mlle Island Nuclear Generating Station,. Route 441 South, Middletown, Pennsylvents 3. PLANT UNIT: 1- ~,.^

4. - OWNER CERTIFICAfl0N OF AUTHORIZATION (if required): None 5.

COMMERCIAL SERVICE DATE: 09/02/74 ~f 6. NATIONAL BOARD N'.MBER FOR UNIT: Reactor Vessel N 109 OUTAGE 8R -TABLE 1 ASME ASME - NDE CAT ITEM NO SYSTEM / COMP 0 KENT COMPONENT ID DESCRIPTION METH MAT DIA REMARKS -...... +....... +................................. +............. +..........,........... +.... +........ +........ +.................... i EF /Pj ing Sg port EF 129 Rigid VT lWA 6 1 .CE2 C2.6 p I l CE2 C2.6 FW / Piping S g port FW 105 Constant VT WA 20 jSeeTable2. I I -CE2 C2.6 FW / Piping Support FW-106 l Constant VT WA ' 14 j l i 'CE2 C2.6 FW / Piping Support FW 107 l Constant VT NA l 14 See Tab-te 2. JE2 C2.6 FW / Piping Support

FW N1B*1 Rigid VT NA 14 C

1; CE2i C2.6' i FV / riping S g port j FW H1B 2 ,GIgid VT NA 14 l -CE2 C2.6 FW / Piping Support FW H18 3 Rigid VT l NA 14 j j l ,.C E-2, C2.6 FW / Piping Support FW N1B 4 Rigid VT NA 14 ...} .CE2 C2.6 FW / Piping' Support FW H1B 5 Rigid VT ,NA 14 l, I~ l } l -CE2 C2.6 FW / Piping $@ port FW H18 6 Rigid jVT NA - 14 i i CE2 C2.6-FW / Piping Support . FW X18 7 Rigid VT NA )14 l CE2 C1.6 - FW / Piping S gport l FW H18 8 l Rigid VT NA 14- .-C E 2 C2.6 ' IC / Piping Support ICH 66 Varietit e VT NA 6 l CE2 C2.6 1P / Pip {ng Support MPAH 3 Anchor VT JNA 6 ( a. I l l1 :C E 2 C2.6 MI /N ping Support MS 048 Rigid lVT 'NA 24 I I CE2 .C2.6 MS / Piping Support MS 051 Algid lVT NA ! 24 ' i l l .CE2 C2.6 MS / Piping Support MS 052 Rigid lVT NA 24 i 1< ( L CE2jC2.6 MS / Piping Support MS 056 , Rigid VT NA 24 .CE2 C2.6 MS / Piping Support MS 057 Rigid VT NA 24 See Table 2. o C E*2 C2.6 MS / Piping Support - MS 065 Srikber VT NA 24 i 23-05/24/90 ~

-_ ( ;.j, ,f 7 h = NIS 1 OWNERS DATA REPORT FOR INSERVICE INSPECTION -

~.
1. ' OWNER: Metropoliten Edison Company, 2600 Pottsville y

Pike, Reading, Pomeylvente - 2. PLANT: Three Mlle Island Nuclear Generating Strtion, Route 441 South, Middletown, Pemsylvente 3. PLANT UNITt i

  1. E 4.

OWWF.R CERTIFICATION OF AUTHORIZATION (if regJired): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NATIONAL 80ARD MUMBER FOR UNIT Reactor Vessel N 109 s OUTAGE 8R TABLE 1 w C .. ASME ASME l NDE l CAT ITEM NO SYSTEM / COMPONENT jCOMPONENTID DESCRIPTION METH MAT DIA REMARKS ...... +....... +................................. +............. +...................... +.... +........ +........ +..................... CE2 C2.6 MS / Piping $@ port MS 067 Verlebte VT l NA 24 V CE2 C2.6 MS / Piping Sgport MS 1E9 Verlebte VT NA 24 L C E 2-C2.6 MS / Piping support MS-190 verlebte VT NA 24 E I CE2 C2.6 MS / Piping $ gport lMS 191 Variebte VT NA 24 (CE'2 .C2.6 MS / Piping Sg port MS 192 Vertable VT WA 24 s g CE2 C2.6 MS /Pipir1 Support MS 196 { Constant VT nA 24 See Table 2. = ' C E*2 C2.6 MS / Piping Support MS 197 Constant VT WA 24 _Q CE2 C2.6 MS / Piping SWPort MS 198 Constant VT NA 24 ~~ CE2 C2.6 l MS / Piping Support MS 203 Snubber VT NA 24 l m E-C-E*2 l C2.6 MS / Piping S@ port MS 229 ' $ nutter VT NA 24 r l CE2 C2.6 MS / Piping Support ' MS 232 ' Ril,N d VT NA 8 5 l

C E 2.

C2.6 MS / Piping Support MS-241 l Rigid lVT jNA 8 See Table 2. l .I l l f CE2 C2.6 MS / Piping Support 1S 242 Rigid lVT WA 8 1 } CE2 C2'.6 MS / Piping Support' lMS262 verlable (VT ' NA 24 1 1 CE2 l'2.6 MS / Piping Sgport MS 287 I Snubber VT NA 24 4 'CE2 C2.6 MS / Piping Support MS 292 ' St%%er VT, NA 24 l Rigid l VT kdA 24 1 See Table 2. -CE2 C2.6 MS / Piping Support MS 308 1 I i CE2 C2.6 - l MU / Piping $4 port lMUH 10 Anchor VT lNA '6 1 CE2 .C2.6 MU / Piping Support MUH 12 lU-Bolt VT NA 6 1 1 CE2 C2.6 MU / Piping Support MUH 13 U Bolt VT l iia 6 \\ I 24-05/24/90 u. K E

., 7 -{t' ~ . +.ju:. 4._ NIS*1 OWNERS DATA REPORT FOR INSERVICE INSPECTION 1. OWNER: Metropotiten Edison Company, 2800 Pottsville Pike, Reeding, Pennsylvanie . 2. ' P'. ANT : Three Mlle Island Nucteer Generating Stetton,' Route 441 South, Middletown, Penneytvante j -3.' PLANT UNIT 1 4. OWNER CERTIFICATION OF AUTHORIZAfl0N (if.rocNired): None - 5. COMMERCI AL SERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor vessel N 109 i OUTAGE 8R-TABLE 1 1 'ASME ASME NDE CAT-ITEM N0 STSTEM / COMPONENT COMPONENT 10 DESCRIPTION METH MAT DIA

REMARKS,

'.....e.......+...............................................+......................+....+........+........+..................... 'CE2 C2.6 MU'/Pipine S p rt MUH 14 U Bolt VT NA 6 CE*2l C2.6 MU / Piping Support MUH 15 U-Bolt VT NA 6 -CE2 C2.6 W /Pipin0 Support WH 8 Anchor VT NA 6 CE2' C2.6 MU /Pipin0 Support MUH 9 ' Anchor VT NA 6 l CG C4.1 AN / Valve AH V1A AH+0004 lBodytoFlengeWeld Mt. CS 48 See Table 2. I I 1 05/24/90 '1 i L k l I l' i l l-1 1 i l

N /. MIS 1 OWNERS DATA REPOR' FOR INSERVICE INSPECTION '

.f 1.'

OWNER: Metropolitan Edison Company, 2800 Pottsville Pike, Reading, Pomaylvents - 2. PLANT: Three Mlle latend F. clear GeneratinB Station, Route 441 Sout*., Middletown, Pennsylvania 3. PLANT UNIT: 1 4. OWNER CERTIFICATFA 0F AUTHORIZATION (if required): None 5.' COMMERCIAL BFt.VICE DATE: 09/02/74 6. NAfl0NAL BOARD NUMBER FOR UNIT: Reactor Vessel N 109 OUTAGE 8R TABLE 1 ASME ASME' NDE j CAT ITEM N0 SYSTEM / COMPONENT , COMPONENT ID DESCRIPil0N METH MAT DIA REMARKS : i q ......e.......+.................................+.............+......................+....+........+........+.....................

  • * *
  • PRE SERVICE EXAMINATIONS ****

'BG2 31.11 RC / Reactor Vessel RC T1 CRDM Bolting Flange Bolting VT CS/SS 1.0 BG1 B3. 5 RC / Steam Generator - RC H 1A Primary Studs MT CS 2.0 and RC N 1B Manway BG1 B3. 5 ] RC / Steam Generator RC H 1A . Primary Studs I,7 CS 2.0 l and RC H 10 . Manway l l BG1 B3. 6 RC / Steam Generator RC N 1A Primary Studs VT l CS !L P D B3.10 RC / Steam Generator

  • RC H 1A Primary JBolting VT CS 1.0 j

.and RC N 1B Manway (. B02 and RC N 1B Han& ole ] l BG1 B3.6 RC / Steam Generator

  • RC H 1A Pr mary Botting VT CS 2.0 8

and RC H 1B Manway BG1 B5.2 RC / Reactor Coolant Pump - RC P1C Lower Seal Housing VT CS 2.0 3 bolts examined. I RC Pic Bolts BG1 B5.2 - RC / Reactor Coolant Ptap +

RC-P1C

! Lower Seal Housing UT CS . 2.0 3 botta examined. RC Pic l Bolts ] 85.2- .RC / Reactor Coolant Ptap - jRCP1C Lower Seal Housing MT CS 2.0 3 bolts examined. j B G-1 .RC Pic. Bolts. 8G1 B5.2 RC / Reactor Coolant Ptap - RC P1D Lower Seal Housing VT CS 2.0 RC P1D l ' Bolts BG1 B5.2 RC / Reactor coolant Pump

  • RC P1D
Lower Seal' Housing MT CS 2.0

.j i. .RC P10 Bolts BG1 95.2 RC / Reactor Coolant Ptap - RC P1D Lower Seal Housing UT CS 2.0 r ( '1 RC P1D ' Bolts CG C2. 1 EF /6" EF Line TO RC H 1A EF 0172BM ' Pipe to Venturl UT, CS/SS 6.0 L i j' CG 'l C2. 1 EF /6" EF Line TO RC N 1A , EF 0173BM Veriurl to Pipe UT CS/SS 6.0 L l' CG C2. 1 EF /6" EF Line TO RC N 18 EF 0174BN Pipe to Venturl l UT CS/SS 6.0 l C-Gi C2. 1 EF /6" EF Line TO RC H 18 EF*0175BM venturl to Pipe UT CF/SS 6.0 l L 1 l I 26-05/24/90 ll 1 ((_

p - .a a ~ O a*l. -? i,. ~ NIS 1 OWNERS DATA REPORT FOR INSERVICE INSPECTION 1.' OWNER: Metropolitan Edison Company, 2800 Pottsville Pike, Reading, Pomsylvania 2. PLANT: Three Mlle Island Nuclear Generating Station, Route 441 South. Middletown, Penrisylvania 3. PLANT UNIT: 1-4. OWNER CERTIFICATION OF AUTHORIZATION (If recpJlred): None 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NATIONAL BOARD NUMBER FOR UNIT: Reactor Vessel N 109 OUTAGE 8R TABLE 2 ASME ASME l lNDE l UNACCEPTABLE INDICATION -CAT ITEM NO SYSTEM / COMPONENT' COMPONENT 10l DESCRIPTION lMETHl AND DISPOSITION. ...... +....... +................................. +............. +...................... +..... +....................................... -BG2 B1.11 RC / Reactor Vessel RC T1 CRDM Bolting Flange Botting VT Exam performed for monitoring of leakage only. Replaced gaskets on 14. drives; remainin, connections were ] acceptable for continued service. BK1 B4. 9 CF /i4" B Line to Reactor CF 0051WA Integral Attachment PT Linear indication accepted by Vessel Weld

analysis,

'B K 1 B4. 9 CF /14" B Line to Reactor' l CF 0052WA l Integral Attachment PT Linear indication considered unchanged 1 Vessel l Weld from previous outage. Accepted by analysis. BK2 B4.10 CF / Piping Support CF 007 Snubber VT l Loose anchor bolts, reset and I retorqued. B-K 2 B4.10 MU / Piping Support , MU 136 1 , Verlable VT Tightened lock nut. BK2 84,10 MU / Piping Support . MU 136 2 variable VT Tightened lock nut. f BK2 84.10 MU / Piping Support MU 136 3 Variable VT Tightened lock nut. 'BK2 84,10 MU / Piping Support. MU 136-6 U Bolt VT Loose base plate and anchor bolts. Anchor bolts reset and torqued. i l l 1. l 'BK2 84.10 MU / Piping Support MU 137 1 U Bolt VT Loose base plate and anchor bolts. Anchor bolts reset and torqued. l BK2 B4.10 MU / Piping Support MU 139 6-variable VT Tightened loose lock nut. l i 1 1 I 1-05/24/90 I l f.' l ic

s14- )/ 9. e ' * * ~ NIS 1 OWNERS DATA REPORT FOR INSERVICE INSPECil0N 1 c

1.. OWNERI Metropolitan Edison Company, 2800 Pottsville Pike, Reading, Pennsylvania--

2. PLANT: Three Mlle Island Nuclear Generating Station, Route 441 South, Middletown, Pennsylvania j 3. PLANT UNiit 1 -] 4. OWNER CERTIFICAfl0N OF AUTHORIZATION (if required): None .I 5.' COMMERCIAL SERVICE DATE 09/02/74 6, Nail 0NAL BOARD NUMBER FOR UNITI Reactor Vessel N 109 OUTAGE 8R TABLE 2 ASME ASME NDE - UNACCEPTABLE INDICATION CAT.- ITEM NO STSTEM / COMPONENT COMPONENT ID DESCRIPTION METH AND DISPOSITION ......e.......+................................+.............+......................,.....+....................................... ~BK2 B4.10 MV / Piping Support .MU 139 7 l Variable VT Tlphtened loose lock nut. BK2 84.10 MU /Pipiro Sgport MU 140 4 Verlebte VT Anchors reset and torqued, corrected base plate gaps and tightened loose hanger bolts i -BK2 .B4.10 MU / Piping Support MU 146-l. U Bolt VT Loose anchor bolts. Anchors reset and retorqued. e

B K 2 B4.10 MU / Piping Support MU 148 04 U Bolt VT Tightened loose nuts.

T i l8K2 B4.10 MU / Piping Sgport MU+149 05 U Bolt VT Tight fit u bolt installed in loc 4e fit design. S g port adjusted to loose l fit configuration. 1 ,BK2 B4.10 MV / Piping Support MU 149-10 lU Bolt VT Loose anchor bolts. Anchors reset and retorqued. 8K2 B4.10 MV / Piping Support MU-149-15 U Bolt VT - Anchors not properly installed. Anchore were reset, j

BK2, 84.10 Mu / Piping Support -

MUH 222 variable VT Tightened upper clam bolts. 4 BK2' B4.10 MV / Piping Support MUH 246 ] Variable VT Tightened clamp bolt. l 1 l. 1 BK21 84.10 MU / Piping Support MUM 219 Variable VT Tightened load bolt. 3 i BK2 84,10 RC / Piping Support RC-12 {$nubber VT Replaced missing washers. l \\ i 05/24/90 a

.f k '.4 ' ahi* l + j w NIS*1 OWNERS DATA REPORT FOR INSERVICE INSPECTION i 1. 0WNER: Metropolitan Edison company, 2800 Pottsville j - Pike, Reading, Pennsylvants' .l 2. PLHT: Three Mlle Island Nuclear Generating Station, - Route 441 South, Middletown, Pennsylvania 'l 3. PLANT UNIT 1 4 OWNER CERTIFICAfl0W OF AUTHORIZAfl0N (if re @ lred): None 5. COMMERCIAL SERVICE DATE: 09/02/74 r-l 6.' NAfl0NAL BOARD NUMBER FOR UNIT: Reactor Vessel W 109 [ OUTAGE 8R TABLE 2-ASME i ASME' lNDE. UNACCEPTABLE INDICATION k CAT l lTEM NO STSTEM / COMPONENT COMPONENT 10 DESCRIPTION lMETH AND DISP 0$lf!ON l ...... +....... +................................. +............. +...................... +..... +....................................... 'B K 2 B4.10 ' RC / Piping Support .RC 34 2 lU Bolt VT Tight fit $nstallation in loose fit' design.' 3 4 port adjusted to loose fit' configuration.. B K-2 B4.10 RC / Piping Support RC 34 3 U Bolt VT Bent U Bolt evaluated as acceptab'le. I ~B K-2 84.10 RC /Plping Support RC 35 2 U Bolt VT Bent U Bolt evaluated as acceptable f l' BK2 B4.10 RC / Piping Support RC 35 3 U Bolt VT Adjusted u-bolt to provide correct gap. BK2 B5.5 RC /Ptap SLpport RC P10 11 Constant VT Tightened loose bolts. CC. C2.1' AH /48" Line - Penetration 423' AH 017S Penetration to Flange MT ltdications removed with minor surface l Weld conditioning. L ICD. C2.4 MS /6" D Relief Line MS-V0200 Flange Bolting VT Loose stud identified. Petorquod all studs on similar valves. i CE1 C2.5 AH /48" line - Penetration 423 : AH 0019WA ' Integral Attachment MT Indication removed with minor surface , Weld conditioning. F I CE1 C2.5 DH /14" B Line to DM T1 DH 0019WA

Integral Attachment PT-

'Irdication removed with minor surf ace l I j

Weld conditioning.

I I I CE2 C2.6 EF / Piping Support lEF118 Rigid lVT Tightened loose clamp bolig. 1 -C-E 2 C2.6 EF / Piping Support l EF 128 Rigid VT Adjusted cotter pin. 3-05/24/90 )! i w = -

K.. : t,M ? m .es ~' 'I NIS 1 CWNERS DATA REPORT FOR INSERVICE INSPECTION-1. CWNER: Metropolitan Edison Company, 2000 Pottryllte Pike, Reading, Pennsylvente- ' 2. PLANT: Three Mlle Island Nucteer Generatin$ Stetton, Route 441 South, Middletown, Pennsylvente 3. PLANT UNIT 1 i 4. 0WNER CERTIFICAfl0N OF AUTHORIZATION (if re@lred): None. 5. COMMERCIAL SERVICE DATE: 09/02/74 6. NATIONAL BOAR 0 NUMBER FOR Uh!T Reactor vessel N 109 OUTAGE 8R TABLE 2 'ASME ASME NDE UNACCEPTABLE INDICAfl0N 'CATL ITEM NO SYSTEM / COMPONENT COMPONENT ID ' DESCRIPfl0N METH AND DISPOSITICH -......e.......+.................................+.............+....4................+.....+....................................... I 'CE2 C2.6 FW / Piping Support . FW 105 Constant VT Installed missing nut and tightened Lock nut. -C E-2 C2.6 'FW /Plping S p rt FW 107 Constant VT Adjusted cotter pin and tightened lock nut. L 4 C I 2: .C2.6 MS / Piping S'upport MS 057 Rigid VT Tightened rod. } t ? CE2 C2.6 MS /olping Support MS 1% ' constant VT Corrected thread engagement, adjusted. lock nut and tightened loose nut. \\ CE2 C2.6 MS / Piping Support MS 241 Rigid VT Retorqued botting to correct plug -i depth.

CE2 C2.6 :

MS / Piping Support MS 308 Rigid VT Tightened rod and turnbuckte. l CC C4.1 AH / Valve AH V1A AH 0004 Body to Flange Weld MT Indications removed with minor surface conditioning. 4 4-05/24/90 i t p r:}}