ML20043D220

From kanterella
Jump to navigation Jump to search
Forwards Request for Addl Info Re Steam Generator Girth Welds.Results of Hardness Tests on Girth Welds & Surrounding Areas & Results of Boat Sample Analyses Will Be Submitted W/Outage Rept
ML20043D220
Person / Time
Site: Zion File:ZionSolutions icon.png
Issue date: 05/10/1990
From: Chrzanowski R
COMMONWEALTH EDISON CO.
To: Murley T
Office of Nuclear Reactor Regulation
References
NUDOCS 9006070275
Download: ML20043D220 (2)


Text

.

1 Commonwealth Edison zion Generatin May 10, 1990

  • / ' " '

' Shiloh Blvd. & gtatione Mchigan

+

Zion. liknois 60099 Tolophone 708 / 746-2004 -

Dr. Thomas E. Murley, Director i

Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC 20555 l

l

Subject:

Zion Station Unit 2

(

l Steam Generator Girth Helds Additional Information 7

NRC Docket No. 50-30_4, l

Reference:

May 1, 1990,' letter from R.A. Chrzanowski to T.E. Murley

Dear Dr. Murley:

The referenced letter provided a detailed description of the Unit 2 Steam Generator Girth Held inspection results.

During a recent teleconference between members of your staff and Zion Station, a final listing of the surface indications removed from the upper transition cone weld area in the Zion Station Unit 2 Steam Generators was requested.

The attachment.to this letter provides the requested information.

Commonwealth Edison has reviewed the flaw evaluation and conc 1'uded l

that the indications are all acceptable.

As indicated in the_ referenced letter, the results of the hardness tests on the girth welds and the l

surrounding areas and the results of the boat sample analyses will be submitted with the Zion Unit 2 outage report.

If any additional questions arise, please direct them to.this office.

Very truly yours, G*DJ R. A Chrzanowski j

Nuclear Liefnsing Administrator cc:

C. Patel - NRR M. Hum - NRR Zion Resident Inspector Region III Office Office of Nuclear Reactor Safety - IDNS l

9006070273 900310 PDR ADOCK 05000304 g.

P ppc

4

<=...

AIJActiMERI i

final Listing of Surface Indications Removed from the Upper l

Transition Cone Held Area - Zion, Unit 2 1

The following is a listing of all of the. surface Indications that were. identified by external UT, verified by internal MT and removed from the upper transttlon cone-weld area:

Hel d Inu Length Hidth Repih 1-6 1

3.00"-

2.50" 0.313" 2-6 1

3.50" 2.50" 0.375" 2-6 2

2.50" 2.25" 0.250" 2-6 3

5,50" 2.50".

0.438" 2-6 4-2.50" 1.75" 0.250"

i 2-6 5A 1.25" l.00" 0.125".

2-6 SB 3.50" 2.25" 0.125" 2-6 6

8.75" 2.00" 0.500" 3-6 1A 1.50" 1.00" 0.125" 3-6 IB 1.25" 1.00" 0.063" 3-6 IC 1.50" 1.00" 0.125" 3-6 2A 1.00" l'.00" 0.125" 3-6 2B 0.75" 0.75" 0.125" 3

3-6 3A l~75" 1.00"~

.0.188" 3-6 3B 3.00" 2.00" 0.438" 3-6 4

2.50' 2.50" 0.375" 3-6 6

1.50" l.50" 0.063" r

4-6 1

2.50" 1.75"'

O.375"-

4-6 2

1.63" 1.50" 0.250" 4-6 3

2.00"-

l '. 7 5 "

0.250" 4-6 4

1.75" 2.38"-

0.313" 4-6 5

3.25" 4.25" 0.563" l

4-6 6

2,00" 2.50"-

0.250" 4-6 7A-7E & 8A-8C 11.00" 2.75" 0.438" All dimensions contained in the above listing refer to the excavated area required to completely remove the indication including blending, i

'