Forwards Technical Review Rept AEOD/T90-07, Reversed Sensing Lines Connections. AEOD Search on Nudocs & Scss Data Base Revealed 19 Addl Events Re Subj Issue.No Further AEOD Action Recommended
ML20043B528
Person / Time
Site: Limerick 
Issue date: 05/24/1990
From: Kaufer B
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
To: Lanik G
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
Shared Package
ML20043B529 List:
References
AEOD-T90-07, AEOD-T90-7, NUDOCS 9005300153
Download: ML20043B528 (1)


Text

'

MEMORANDUM FOR:

George F. Lanik, Acting Chief Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis and Evaluation

)

of Operational Data c

FROM:

Barry Kaufer, Reactor Systems Engineer Reactor Systems Section GE & CE Reactor Operations Analysis Branch Division of Safety Programs Office for Analysis end Evaluation of Operational Data

SUBJECT:

REVERSED SENSING LINES CONNECTIONS Enclosed is our Technical Review on Reversed Sensing Lines Connections.

^

In LER 50-353/90-002, philadelphia Electric Company documented reversed connections of sensing lines to a containment hydrogen / oxygen analyzer.

The root cause of this event was mislebeling of inlet / outlet ports, resulting in the reversed connections.

Our search on NUDOCS and SCSS database revealed 19 additional events relating to this issue. All of these events were caused by inadequate design documents, deficient procedures, and insufficient verification methods. Considering the relatively small frequency of these occurrences and the limited safety significance, no further AE0D action is recomended.

Original signed by Barry Kaufer, Reactor Systems Engineer Reactor Systems Section GE & CE Reactor Operations Analysis Branch Division of Safety Prograins Office for Analysis and Evaluation of Operational Data

Enclosure:

As stated cc w/ enclosure:

H. Faulkner, IP D. Queener, NOAC J. Wheelock, INPO Distribution:

Y"f9R4 EJordan KBlack Central File Dross R$avio, ACRS ROAB R/F TNovok MTaylor, EDO DSP R/F LSpessard KReglin, TTC AEOD R/F SRubin FBaranowsly. NRR BKaufer GZech flSu MWilliams Glanik JRosenthal ROAB:DSP:AE D ROAB:

OD AC:RhkidSP:AE0D BKaufer:

TSu GLa'n'i k fi 5/pl/90 5/>F/90 5/p/90 i fo}

9005300153 000524 PDR ADOCN 05000353 1 j~

P PDC

(