Forwards Safety Insp Rept 70-1100/90-02 on 900212-16 & Notice of Violation.Violation Concerned Failure to Maintain Records of Criticality Safety Evaluation
ML20042D725
Person / Time
Site: 07001100
Issue date: 03/26/1990
From: Ronald Bellamy
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To: Waterman C
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
Shared Package
ML20042D726 List:
References
NUDOCS 9004050183
Download: ML20042D725 (2)


Text

_

l MAR 2 61990 1

Docket No. 70-1100 Combustion Engineering, Inc.

ATTN: Mr. C. R. Waterman Acting Vice President - Nuclear Fuel Nuclear Power Systems 1000 Prospect Hill Road Windsor, Connecticut 06095-0500 Gentlemen:

Subject:

Inspection Report No. 70-1100/90-02 This refers to the special safety inspection conducted by Mr. J. Roth of this office on February 12-16, 1990, for the purpose of reviewing your manufacturing operations, management controls, training, criticality safety, maintenance and transportation activities. The inspection consisted of selected examination i

of procedures and representative records, interviews with personnel and observations by the inspector.

Within the scope of this inspection, one violation was identified.

That violation concerned a failure to maintain records of 3 criticality safety. evaluation.

You are required to reply to this matter ir, accordance with the enclosed Appendix A.

The response directed by.this letter and the accompanying Notice is not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

4 Your cooperation with us is appreciated.

Sincerely, Ordnd Signed By:

James H. J0yner Ronald R. Bellamy, Chief i

Facilities Radiological Safety and Safeguards Branch Division of Radiation Safety and Safeguards

Enclosures:

1.

Appendix A, Notice of Violation 2.

NRC Region I Inspection Report No. 70-1100/90-02

} f* l

?

$(*k-0FCICIAL RECORD COPY IR CE 90 0001.0.0 03/19/90 900A0501e3 90933$

l

[.DR ADOCK 07001100 eDe

l Combustion Engineer:ng, Inc.

2 MAR 2 01993 i

cc w/encis:

A. E. Scherer, Director, Nuclear Licensing C. B. Brinkman, Manager, Washington Nuclear Operations Public Document Room (PDR) local Public Document Room (LPDR)

Nuclear Safety Information Center (NSIC)

State of Connecticut bec w/encir.

Region I Docket Room (with concurrr.nces) i Management Assistant, DRMA (w/o er,cis)

J. Roth, DRSS G. Bidinger, NHSS J. Joyner, DRSS M. A. Austin, DRSS I

I l

l l

1 l

RI:DRSS 3

RSS R

RjS ores oyner e-amy R

1/mk/s13 03/.10/90 03/27/90 03/86/90 03 90 0FFICIAL RECORD COPY IR CE 90-02, 0002.0.0 1

03/19/90 l