ML20042C181

From kanterella
Jump to navigation Jump to search
Summary of 820303 Meeting W/Util in Bethesda,Md Re Seismic Site Specific Spectra
ML20042C181
Person / Time
Site: Wolf Creek 
Issue date: 03/15/1982
From: Hopkins J
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8203300320
Download: ML20042C181 (3)


Text

~

,.g.

y 4

f, p

g y

1 s

s s

pR 151982

[r.

i g

VIR32/g8s 3; Docket No.
STN 50-482 U

7

-\\y*w b((.74

~

e.

APPLICAllT: Kansas Gas and Electric Company y

FACILITY:

Wolf Creek Generating Station, Unit 1

SUBJECT:

SUH1ARY OF !!EETIhG HELD ON tlARCH 3,1982, WITH WOLF CREEK APPLICANT A meeting was held on March 3, 1982, at the Air Rights Building in Bethesda, Maryland, with representatives of the Kansas Gas and Electric Company. The purpose of the meeting was to discuss matters related to the Seismic Site-Specific Spectra applicable to Wolf Creek. The list of attendees is attached as Enclosure 1.

The significant points discussed are sumarized as follows:

1.

D. Bernreuter of Lawrence Livermore National Laboratory (LLNL) presented a sunnary of his report on Wolf Creek. His work involved 2 main areas, (1) a Seismic Hazard Analysis, and (2) the development of Seismic Site-Specific Spectra using real records.

2.

The LLhl site-specific spectra that was developed from real records showed some exceedance of the applicant's spectra developed from Regulatory Guide 1.60 based on 0.129. NRC stateo that this exceedance is typical of other plants and not considered large.

3.

The NRC has not accepted (or rejected) the LLNL report and its findings at this time.

4.

Regardless of whether the NRC accepts or rejects the report, the LLNL findings did not exceed the 0.29 design of the SNUPPS portion of Wolf Creek, and therefore, the accepted SNUPPS seisaic design and analysis is not affected.

5.

The NRC staff indicated that its review of the report would be complete the week of tiarch 8 to determine if further Wolf Creek site-specific analysis is necessary.

/s J n B. Hopkins, Project Manager 8203300320 020315 PDR ADOCK 05000482 Licensing Branch No.1 A

PDR Division of Licensing

Enclosure:

As stated

_g

""">,..cc;.... S_ep..nex.%..p. age...... I DL : LB#10%.

p

~

.N19Dki IXL.00.Yk

..] 99$

.n >............. '..

3//h82 3/

2

....l....

sse r: m aie oo,eoino. u o u o OFF1CIAL RECOFiD COPY

'" '88o-32"a

,c Mr. Glenn L. Koester Vice President - Nuclear Kansas Gas and. Electric Company 201 North Market Street Post Office Box 208 Wichita, Kansas 67201-cc: Mr. Nicholas A. Petrick Ms. Wanda Christy Executive Director, SNUPPS 515 N. 1st Street 5 Choke Cherry Road Burlington, Kansas 66839 Rockville, Maryland 20750 Eric A. Eisen, Esq.

Mr. Jay Silberg, Esquire Birch, Horton, Bittner & Moore Shaw, Pittman, Potts & Trowbridge 1140 Connecticut Avenue, N. W.

1800 M Street, N. W.

Washington, D. C.

20036 Washington, D. C.

20036 Kansans for Senible Energy Mr. Donald T. McPhee Post Office Box 3192 Vice President - Production Wichita, Kansas 6720I Kansas City Power and Light Company 1330 Baltimore Avenue C. Edward Peterson, Esq.

Post Office Box 679 Legal Division Kansas City, Missouri 64141 Kansas Corporation Commission StaM Office Building, Fourth Floor Ms. Mary Ellen Salva Topeka, Kansas 66612 Route 1, Box 56 Burlington, Kansas 66839 John M. Simpson, Esq.

A. Scott Cauger, Esq.

Attorney _for Intervenors Assistant General Counsel 4400 Johnson Drive, Sutie 110 Public Service Commission Shawnee Mission, Kansas 66205 P. O. Box 360

  • v.

Jefferson City, Missouri 65102 Mr. John T. Collins NRC Region IV Mr. Tom Vandel 611 Ryan Plaza Resident Inspector / Wolf Creek NPS Suite 1000 c/o U.S. N.R.C.

Arlington, Texas 76011 Post Office Box 311 Burlington, Kansas 66839 Mr. Joe Mulholland Manager of Power Supply & Engineering Mr. Michael C. Keener-Kansas Electric Power Cooperative, Inc.

State Corporation Commission Post Office Box 4877 State of Kansas Gage Center Station Fourth Floor, State Office Bldg.

Topeka, Kansas 66604 Topeka, Kansas 66612-Terri Sculley, Director Special Projects Division Kansas Corpoeration Commission State Office Building, Fourth Floor Topeka, Kansas 66612 i

_= -

s.

e o

List of Attendees Meeting of March 3, 1982 NRC Union Electric J. Hopkins A. Passwater G. Edison P. Sobel J. Kimball R. Jackson C. Tan A. Lee D. Bucci LLNL D. Bernreuter KG&E G. Rathbun M. Johnson C. Sprout D. Green SNUPPS R. Stright Dames & Moore R. Rospenda C. Scawthorn D. Fenster Sargent & Lundy L. Holish J. Kutin Bechtel K. Lee B. Meyers a

R. Burris L. Rotondo

. E. T hoi,1a s

P. Labarta i

R. Boldnikaiz i

J. Litehiser l

t I

r i

s MEETING

SUMMARY

DISTRIBUTION J ? Docket' File.

G. Lear NRC PDR '

W. Johnston Local PDR UAR 15 NE-S..Pawlicki TI,C/NSIC/ Tera V. Benaroya Z. Rosztoczy LB#1 Reading W. Haass H. Denton/E. Case D. Muller R. Ballard D. Eisenhut/M. Jambor W. Regan R. Mattson B. J. Youngblood A. Schwencer F. Congel F. Miraglia

0. Parr J. Miller F. Rosa G. Lainas W. Butler R. Vollmer J. P. Knight R. Houston R. Bosnak F. Schauer L. Rubenstein R. E. Jackson T. Speis Project Manager JHopkins M. Srinivasan Attorney, OELD J. Stolz M. Rushbrook S. Hanauer OIE (3)

W. Gammill ACRS (16)

W. Minners F. Schroeder E. Adensam D. Skovholt M. Ernst NRC

Participants:

L. Hulman C. Berlinger JHopkins K. Kniel GEdison G. Knighton PSobel A. Thadani JKimball RJackson J, Kramer CTan Atee D8ucci D. Ziemann bec: Applicant & Service List l

9

-.