ML20042C094

From kanterella
Jump to navigation Jump to search
Revises Re Corrective Action for Ge/Mac Cold Leg Flashing Problem,Per GE Svc Info Ltr 299,Suppl 1.Procedures Revised to Include Max Error Values for Ge/Mac Indicators & Recorders to Determine Actual Reactor Water Level
ML20042C094
Person / Time
Site: Hatch  
Issue date: 03/23/1982
From: Beckham J
GEORGIA POWER CO.
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8203300189
Download: ML20042C094 (1)


Text

Getyga Pcer Company 333 Pedmont A wnue at:anta Goorg a 303C8 TcMphone 404 526-7020 Mainq Adfrew Post oke Bc;x 4545 Ananta oecrya mc2 March 23,1982 Georgia Power

~ 7 "l j(b-J. T. Beckham, Jr.

Vice Pres dent and Ge ere Manager Q

Nuclear Generatan N

0

'\\

Director of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission 2

/%,,

~

Washington, D. C.

20555 gj CL m a ' JP %

t

%w NRC DOCKETS 50-321, 50-366 q-OPERATING LICENSES DPR-57, NPF-5

\\

EDWIN I. HATCH NUCLEAR PLANT UNITS 1, 2 NG' REVISION OF REPORT FOR IMPLEMENTATION OF SIL 299 SUPPLEENT 1 Gentlemen:

Our letter of February 10, 1982, concerning the status and schedule of implementation of General Electric Service Information Letter (SIL) 299 and supplement advised you that corrective action for the GE/MAC cold leg flashing problem would be accomplished by procedure revision to the plant procedure for Pipe Break Inside Primary Containment to provide operators with a method for determining the true reactor water level, as indicated by the GE/MAC instruments, under accident. conditions.

However, further investigation into the GE/MAC cold leg flashing problem showed that the actual reactor water level is dependent upon several parameters (for example:

Reactor Temperature and Pressure, Drywell Temperature, Reactor Building Temperature) and must be determined by a complex formula whic.h would be impractical for use during accident conditions.

Consequently, it was decided to revise procedures to include a maximum error value for each indicator and recorder (GE/MAC) ( As was recommended by SIL 299, Supplement 1).

This value is that which would exist under the worst postulated accident condition, and is therefore conservative for any others.

Procedure revision requests for the effected procedures (to include these maximum error values) were approved by the Plant Review Board on February 18, 1982.

If you have questions concerning this information, please contact this office.

Yours very truly,

. T. Beckham,iJr.

WEB /mb xc:

M. ManIy 5

R. F. Rogers, III J. P. O'Reilly (tRC - Region II) 7 8203300189 820323 PDR ADOCK 05000321 P

PDR

,