ML20042B995

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5687,Revision 1 for Model RMG-184
ML20042B995
Person / Time
Site: 07105687
Issue date: 03/17/1982
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML20042B993 List:
References
NUDOCS 8203290100
Download: ML20042B995 (3)


Text

.

.F NRCC18 U.S. NUCLEAR REGULATORY COMMISSloN I

CERTIFICATE OF COMPLIANCE 10 CFR 71 Fcr R dioactive Mittrials Picktges 1.(I) Certificate Number 1.(b) Revision No.

1.(c) Package Identification No.

1.(d) Pages No. 1.(e) Total No. Pages 5687 1

USA /5687/Bf 1F 1

3

2. PRE AMBLE 2.(a)

This certificate is issued to satisfy Sections 173.333a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-Ina and 146--19-100 of the Department of Transportation Dangerous Cargoes Reg,ulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package w?! be transported.

3. This certificate is issued on the basis of a safety analysis report of the package desip or application-3.(a)

Prepared by (Name and address):

3.(b)

Title and identificatir.,a of report or application:

Nuclear Fuel Services, Inc.

Nuclear Fuel Services, Inc. application dated P.O. Box 218 June 11, 1974, as supplemented.

Erwin, TN 37650 3.fc)

Docket No.

~

4. CONDI.lONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Authorized Contents, Modet Number, Fissile Class, Other Conditions, and

References:

(a)

Packaging (1) Model No.:

RMG-184 (2) Description The containment vessel is a 5-gallon bucket, D0T Specification 174 or equivalent. Closure is by means of a log clamp used with a new lid for each shipment. Uranium enriched greater than 6% shall be contained in a 3-gallon metal can or plastic bottle surrounded by vermiculite within the 5-gallon bucket.

The outer container, a 55-gallon DOT Specification 17H steel drum, or equivalent, is closed by a 12-gauge bolted ring with drop forged lugs, one of which is threaded, having a 5/8-inch bolt. The containment vessel is supported in the outer container by two, 26 gauge sleeves filled with tamped vermiculite and fire retardant polyurethane foam.

(3) Drawing The packaging is constructed in accordance with Nuclear Fuel Services, Inc. Drawing No. RMG-184.

l 8203290100 820317 PDR ADOCK 07105697 C

PDR i

)

Page 2 - Certificate No. 5687 - Revision No. 1 - Docket No. 71-5687 5.

(b)

Contents (1) Type, form, and. maximum quantity of material per package (i) 0xides of uranium, at uranium densities not to exceed 3.2 g/cc.

Not to exceed one hundred pounds of product with the maximum enrichment in the U-235 isotope not to exceed 10 w/o.

H/U-235 ratio, considering all sources of moderation within containment vessel and maximum U-235 content must not exceed:

Enrichment Maximum U-235 Content

% U-235 H/U-235 Kilograms 1

20 0.401 2

10 0.802 3

5 1.203 4

5 1.604 5

3 2.005 6

3 2.405 7

3 2.805 8

2 3.205 9

2 3.605 10 2

4.005 (ii) Uranium oxide or metal, at uranium densities exceeding 3.2 g/cc.

Not to exceed one hundred pounds of product with the maximum enrichment in the U-235 isotope not to exceed 5 w/o.

H/U-235 ratio, considering all sources of moderation within containment vessel and maximum U-235 content must not exceed:

Enrichment Maximum U-235 Content

% U-235 H/U-235 Kilograms 1

20 0.401 2

10 0.802 3

5 0.700 4

5 0.700 5

3 0.700

a

/

Page 3 - Certificate No. 5687 - Revision No. 1 - Docket No. 71-5687 5.

(c)

Fissile Class II and III (1) Minimum transport index Maximum to be shown on label Enrichment Transport for Class II

% U-235 Index 3

0.2 7

0.4 10 0.7 (2) Maximum number of Maximum packages per ship Enrichment Number of

~

ment for Class III

% U-235 Packages 3

1,550 5

390 7

330 10 234 6.

The package authorized by this certificate is hereby approved for use under the general li. cense provisions of 10 CFR 971.12(b).

7.

Expiration date:

September 30, 1982.

REFERENCES Nuclear Fuel Services, Inc. application dated June 11, 1974.

Supplements dated:

November 11, 1966; and January 25 and November 2, 1967.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

MAR 171982

.