Text
1 e
I GPU Nuclear
]
g{
P.O. Box 480 Middletown, Pennsylvania 17057 717-944-7621 Writer's Direct Dial Number:
March 22, 1982 5211-82-072 tn g, 5 office of Nuclear Reactor Regulation Attn: John F. Stolz 1
O'
- ~r'M J Division of Licensing Operating Reactors Branch No. 4 m
U. S. Nuclear Regulatory Commission f
lGR 2 G 1992> jL Washington, D.C.
20555
$ Dr moumwm '
rr.ni wxE::J :1 g
Dear Sir:
\\
Three Mile Island Nuclear Station, Unit 1 (TMI-1) d Operating License No. DPR-50 Docket No. 50-289 Reactor Building Purge (NUREG 0737 II.E.4.2)
This letter is written to provide the historical background (Attachment 1) and closcout of the subject issue. Technical Data Report No. 283 (Attach-ment 2) shows, using conservative assumptions, that the purge valves will close against the forces present during the Design Basis Accident - Loss of Coolant Accident (DBA-LOCA) if limited to 300 open angle.
In fact, the research indicates that, given the actual expected pressure increase post-accident, and the design response for the containment isolation valve control system, none of the valves would have difficultly closing from the 90 open position. The limiting stresses and limiting angle of opening are based on the assumption that the R.B. pressure increare is instantaneous.
Actually the valves would be expected to be closed at much lower than R.B.
peak pressure, even from 90 start position.
Though we may, in the future, request and justify relief from the 30 opening restriction we are committing to limiting our purge valves (AH-VlA/lB/lC/lD) to 30 open until such a request is approved by the NRC.
The 30 opening limits have already been installed and will remain functional during all periods when containment integrity is set.
If during plant operation, any valve needs to be opened further, for maintenance, the oth-r valve in series will be maintained in the full closed position.
Sincerely, s
D. Nu ill HDil:RLS:vj f Director, TMI-l O
Attachments k
cc:
R. C. Ilaynes fg k R. Jacobs L. Barrett 8203260218 820322 PDR ADOCK 05000289 is a part of the General Pubhc Utikties System P
ATTACIDfENT I Correspondence History on Reactor Building Purge a)
NRC Letter to Met-Ed dated November 29,1978 " Containment Purging During Normal Operation".
b)
Met-Ed Letter to NRC dated January 4, 1979 (GQL 0007) " Containment Purging".
c)
Met-Ed Letter to NRC dated March 16,1979 (GQL 0332) " Containment Purging".
d)
Mot-Ed Letter to NRC dated August 7,1979 (GQL 0997) " Containment Purge".
c)
NRC Letter to Met-Ed dated September 27, 1979 " Guidelines for Valve.
Operability".
f)
Met-Ed Letter to NRC dated November 20,1979 (GQL 1440) " Containment Purge".
g)
NRC Letter to Met-Ed dated January 9,1980.
h)
NRC Letter to Met-Ed dated. January 28, 1980 " Containment Purge and Venting during Normal Operation".
1)
Mot-Ed Letter to NRC dated March 11, 1980 (TLL 113) " Purge Va lves".
J)
Met-Ed Letter to NRC dated March 25, 1980 (TLL 126) " Purge Valves".
k)
Met-Ed Letter to NRC dated Apr_il 3, 1980 (TLL 157) " Purge Va lves".
l)
Met-Ed Letter to NRC dated April 30, 1980 (TLL 206) " Containment Purge".
i i
m)
Met-Ed Letter to NRC dated April 30, 1980 (TLL 172) " Purge Valves".
n)
Met-Ed Letter to NRC dated May 9,1980 (TLL 229) " Containment Purging and Venting During Normal Operations".
o)
NRC Letter to Met-Ed dated November 5, 1980 " Confirmation of Commitment to Staff's interim Position on Containment Purging and Venting".
p)
NRC Letter to Met-Ed dated October 31, 1980 "NUREG 0737".
q)
Met-Ed Letter to NRC dated November 17,1980 (TLL 532) " Reactor Building Purge and Exhaust System".
r)
Met-Ed Letter to NRC dated February 6, 1981 (L1L 015) " Containment Purging and Venting".
s)
Met-Ed Letter to NRC dated July 2, 1981 (L1L 199) " Reactor Building Purge Valves".
L w."
7-W__
MnA W