.A DISTRIBUTION:'
Docket' File 50-443/444 LPDR PDR FEB 2 51982 NSIC ACRS (16)
William C. Tallman TERA Chairman and Chief Executive Officer LB#3 Files Public Service Company of New Harapshire RTedesco 1000 Elm Street Filiraglia Manchester, New Hampshire 03105 LWheeler IE (3)
Dear 14r. Tallnan:
Subject:
Senior 11anagement Review of nstruction Progress On Septeuber 15-17, 1981, the NRC staff met with Public Service Company of New Hampshire to review the status of construction of Seabrook Unit 1 and the schedules for construction completion. The ueeting included a tour of all the Unit 1 structures and associated on-site laydown areas. There were also discussions with your representatives that focused on scheculing and providing support for the renaining construction work. Based on that meeting, the NRC staff concluded the reraaining work on Unit I would not appear to be completed until December,1984, assuming typical industry-wide construction performance. This conclusion was based on observations during the site tour, data provided by the utility representatives, and extensive observations of construction progress at sinilar projects throughout the incustry. In contrast, your projected construction completion date is hovember,1983.
In his closing re.aarks on September 17, 1981, Mr. Louis L. Wheeler, the NRC Seabrook Project Manager, stated that nectings may be scheduled in the future to afford your manageaent personnel an opportunity to provide. senior NRC officals with an understanding of the basis for your Hovember,1983 projection. A proposed agenda for such a meeting that would be held on March 24, 1962 in bethesda is enclosed. You are encouraged to notify the Project flanager if adjustments to this agenda are appropriate to more accurately reflect the substance of your participation.
Sincerely, bP Rouert L. Tedesco, '.ssistant Director 8203240505 820225 PDR ADOCK 05000443 (s
for Ljcensjng A
PDR Division of Licensing _
(
Enclosure:
Proposed Agenda cc: See next page.
A
" ' " >..D.L ; L.#.
- .3,,,,,,,DLh,L,,,,,
?=~ ht.Wtw e.db... F.Nal.i.a..
A.
.e.s.co.,.
om>
... 2./.p.../. 82......2 2....
. 2./J... 32.......
NRC FORM 318 4tO 80lNRCM O240 OFFICIAL RECORD COPY
' e m2=
SEABROOK William C. Tallman Chairman and Chief Executive Officer Public Service Company of New' Hampshire P. O. Box 330 Manchester New Hampsnire 03105 Jonn A. Ritscher, Esq.
E. Tupper Kinder Esq.
Ropes and Gray Assistant Attornej General 225 Franklin Street Office of Attorney General Boston,-Massachusetts 02110 208 State House Annex Concord, New Hampsnire 03301 Mr. Bruce B. Beckley, Project Manager Public Service Company of New Hampshire Tne Honorable Arnold Wight P. O. Box 330 New Hampshire House of Representatives Manchester, New Hampshire 03105 Science. Technology and Energy Committee State House G. Sanborn Loncord, New Hampshire 03301 U. S. NRC - Region I 631 Park Avenue Resident inspector King of Prussia, Pennsylvania 19406 Seabrook Nuclear Power Station c/o U. S. Nuclear Regulatory Commission Ms. Elizabeth H. Weinhold P. O. Box 700 3~ Godf rey Avenue Seabrook, New Hampshire 03874 Hampton, New Hampshire 03842 Mr. John DeVincentis, Project Manager Robert A. Backus, Esq.
Yankee Atomic Electric Company O' Neill, Backus and Spielman 1671 Worcester Road
'16 Lowell Street Farmingham, Massachusetts 01701 inchester, New Hampshire 03105 Mr. A. M. Ebner, Project Manager 2rman Ross Esq.
United Engineers and Constructors
] Francis Street 30 Soutn 17th Street rookline, Massachusetts 02146 Post Office Box 8223 Philadelphia, Pennsylvania 19101 r,arin P. Sheldon, Esq.
Sheldon Harmon & Weiss Mr. W. Wrignt, Project Manager 1725 I Street, N. W.
Westinghouse Electric Corporation Washington, D. C.
20006 Post Office Box 355 i
Pi ttsburg, Pennsylvania 15230 l
Laurie Burt, Esq.
Office of the Assistant Attorney General Thomas Dignan, Esq.
Environmental Protection Division Ropes and Gray One Ashburton Place 225 Franklin Street i
Boston, Massacnusetts 02108 Soston, Massachusetts 02110 D. Pierre G. Cameron, Jr., Esq.
General Counsel Public Service Company of New Hampshire i
P. O. Box 330 Manchester,- New Hampshire 03105 t--
O PROPOSED AGENDA PSNH - NRC SENIOR MANAGEMENT MEETING.
Room P-110, Phillips Building Bethesda, Maryland March 24,1982 9:00 AM Introductory comments NRC: Mr.' Darrell G. Ei senhut PSNH: Mr. David N. Merrill 9:05 AM PSNH presents basis for Novem.ber,1983 construction completion date.
Discussions to include:
o Current status of systems installation o Size and conposition of the work force o Critical and near-critical oath work schedules o Status of bulk commodities o Brief comments on financial commitments to complete the plant o Impact of any recent NRC actions 10:05 AM NRC (Caseload Forecast Panel) presents the basis for the December, 1984 date.
10:30 AM Recess. NRC management convenes to consider its assessment of the two presenta tions.
10: 45 AM NRC management discusses its conclusions with PSNH.