BOSTON EDISON COMPANY PROMPT REPORTA3LE OCCURRENCE s

TELECOPY MESSAGE 00 TO: (2 15) 337-5324 DATE/ TIME:

/

Telephone Number TO: Director, Region I 3 - FROM: Pilgrim

' leirl(o Sta.

Office of Inspection and Enforcement RFD#1 Ykf Hill Ra'a

. tM MA 02360 V,N U.' S. Nue1. ear Regulatory Commission P1

'/

2'

& }f" ' ' 3 d 19 3 2 :> $

{,

631 Park Avenue King of Prussia, PA 19406

[I-Docket Number 50-29p ES {

g 7

License DPR-35

\\g ti 82-006/0 m 0 ReportedperYS'.Section 6.9.

1.1 Assigned LER Number

"[T& \\f Event

Description:

The HPCI stop valve main disc flange which shou die attached to the main disc by four cap screws, was found with three of the cap screws broken This flange is a ported unit intended to function in concert with an internal pilot valve to ensure stable opening of the turbine stop valve.

Cause and Corrective Action:

This problem was discovered while maintenance was being performed on the pressure adjustment. mechanism for the Stop Valve's steam balance chamber per SIL No. 352. The four cap screws have been retrieved for ex-amination, and a request for engineering planning and support submitted to as-certain the reason for this event.

I la Facility Status:

0

% Thermal MW c) Routine Startup g) Shutdown e)

Steady State h) Refueling y

d) Routine Shutdown

1) Other f) Load Changing j) Not Applicable A written followup report will be sent within two weeks.

NRC Person Notified Mr. H. Eichenholz Prepared by M. T. McLoughlin 1

cc: Standard LER Distribution

/

Mail (2) copies to:

Director Office of Management Information and Program Control U. S. Nuclear Regulatory Cons:ission Washington, D.C.

20555 82032304S1 820309 p,g DR ADOCK 05000 2n

~

-.--.- -