March 12, 1982
'I'CO 3
Docket No.: 50-537 AIAR1 y1982w.:g um 2
APPLICANT: Department of Energy. TVA,and PMC
/
FACILITY:
Clinch River Breeder Reactor
SUBJECT:
SUMMARY
OF FEBRUARY 12. CRBR REVIEW MEETING A meeting was held on February 12, 1982 in Bethesda, liaryland to discuss the auxiliary liquid metal systems found in Chapter 9 of the CRBR PSAR.
The applicants described the design bases, functions, design criteria, and system classification for equipment and systems documented in the PSAR.
The systems discussed included: heating ventilating and air conditioning systems; the chilled water system; the plant service water system; the atmospheric filtration systems; the fire protection system; the diesel generator support systems; the floor drainage systems; the reactor refueling system; and, the piping and equipment electrical heating and control system.
The flRC staff and consultants indicated that the staff review of Chapter 9 was on schedule and that formal staff questions would be issued early in
?! arch 1982. The meeting attendee listing is attached to this summary.
Richard it. Stark, Project Manager CRBR Program Office Office c4 Nuclear Reactor Regulation
Enclosure:
As stated 8203220204 820312 PDR ADOCK 05000537 A
PDR su auch R,,
s
.. 3/g../.@...
.M//l.8,2,,,
orre >
nac ronu ats oow ancu oaa OFFICIAL RECORD COPY usom e-m*o
~
Distribution Docket File bec: Applicant Service List NRC PDR Local PDR NSIC CRBRP0 File H. Denton D. Eisenhut R. Vollmer R. Mattson S. Hanauer g
H. Thompson g
J. P. Knight 4
RECElygg 9
9 P. Check
?
h1AR R. W. Houston Cu II982b I&
L. Rubenstein
'a f'
F. Schroeder l4' M. Ernst s
ACRS (16) a d
OI&E (3)
S. Treby (0 ELD)
V. Moore B. Grimes
' ^
R. Woodruff Region II Administrator
~..
EDO (4)
L. S. Tong NRC Participants J. A. Olshinski, Reg. II R. E. Ireland, NRC-Idaho J. Austin B. D. Liau J. Glynn P. Wood Receptionist - Phillips Bldg.
CRBR Staff J. Long R. Jackson Charlie Thayer, Reactor Training Center, Chattanooga
Auxiliary Liquid Systems 2/12/82 Richard Stark NRC Bethesda Tom Wehner LANL Los Alamos Jay Goode EG&G Idaho John K. Rawlins EG&O Idaho Bob Copp EG&G/CRBRP0 Bethesda Ted Kinnaman EG&G Idaho Jim Glynn NRC/CRBR Bethesda H. B. Holz NRC/CRBR Bethesda Kushal Jain Burns & Roe Oradell, NJ David Ennis Buran & Roe Oradell, NJ P. Fazeuas Burans and Roe Oradell, NJ Karl Schendel W-LRM Oak Ridge Lacy Hyde W-LRM Oak Ridge John Hagelston Rockwell Int'l.
Conoga Park, CA Leonard Baunnish Rockwell Int'l.
Conoga Park, CA George Berg Rockwell Conoga Park, CA Wayne Pasko CRBRP0 Oak Ridge Douglas Hornstra CRBRP0 Oak Ridge Lonnie Kepley CRBRP0 Oak Ridge Delbert Killian EG&G Idaho H. Loweil Magleby EG&G Idaho F.B. Litton MTEB-NRC Bethesda A. Bice ACRS Wash. D.C.
Jerry Swift NRC/CRBRPO Bethesda Ernie Sylvester NRC/DSI/ASB Bethesda George Clare Westinghouse Oak Ridge Bernie Mann NRC/DSI/ASB Bethesda Stephen Additon Westinghouse Bethesda D. Moran NRC/CRBRP0 Bethesda R. Lobel NRC/DSI/ASB Bethesda
r s
. cc:
Dr. Cadet H. Hand, Jr., Director Barbara A. Finamore Bodega Marine Laboratory S. Jacob Scherr University of California Ellyn R. Weiss P. O. Box 247 Dr. Thomas B. Cochran Bodega Bay, California 94923 Natural Resources Defense Council, Inc.
Daniel Swanson 1725 I Street, N.W.
Office of the Executive Suite 600 Legal Director Washington, D.C.
20006 U. S. Nuclear Regulatory Commission Eldon V. C. Greenberg Washington, D.C.
20555 Tuttle & Taylor 1901 L Street, N.W.
William B. Hubbard, Esq.
Suite 805 Assistant Attorney General Washington, D.C.
2007S State of Tennessee Office of the Attorney General L. Ribb 450 James Robertson Parkway LNR Associates Nashville, TN 37219 Nuclear Power Safety Consultants 8605 Grimsby Court William E. Lantrip, Esq.
Potomac, MD 20854 City Attorney Municipal Building P. O. Box 1 Oak Ridge, TN 37830 George L. Edgar, Esq.
Morgan, Lewis & Bockius 1800 M Street, N.W.
Washington, D.C.
20036 Herbert S. Sanger, Jr., Esq.
General Counsel Tennessee Valley Authority Knoxville, TN 37902 Chase Stephens, Chief l
Docketing and Service Section l
Office of the Secretary l
U. S. Nuclear Regulatory Commission Washington, D.C.
20555 Raymond L. Copeland l
Project Management Corp.
P. O. Box 0 Oak Ridge, Tennessee 37830
. -.