March 9,1982 Docket No.: 50-537 APPLICA!sT: Department of Energy, TVA and Plic FACILITY:
Clinch River Breeder Reactor
SUBJECT:
SUfMARY OF FEBRUARY 25 and 26, 1982 CRilR REVIEW MEETING A meeting was held on February 25 and 26,1982 in Bethesda, Maryland to discuss Chapter 15 of The Clinch River Breeder Reactor PSAR. The applicant presented an overview of the accidents analyzed in Chapter 15 and followed with detailed presentations of Sections 15.1 through 15.4.
Detailed discussions included: fuel and blanket design criteria, plant protection system trip function design, reactivity insettion events, undercooling events, the sodium water reaction event and local failure events.
Sections 15.5 through 15.7 were not discussed and will be the subject of a future meeting. The applicant will also provide additional information on the sodlum water interaction event with assumed single failures in the associated water systems. A list of attendees is enclosed.
ORIGrKG sinnrn BY Richard it. Stark, Project Manager CRBR Program Office
/
Office of Nuclear Reactor Regulation Enclosure cc: Service List 4
x
................ =.
- m. a n. a a **.. *= a.
a...**.=~~.~=*
OFFICE) suw.m >...Rh,a r,@,c.,
,,C,T h,9,m,a,s,,,,,,,,,
.../.p..../.82 3
..../.."a./.82 3
.................ame
.a.
* * *. = * *.. *
- "=a.***
DATFk 8203190211 820309 knc PDR ADOCK 05000537 OFFICIAL RECORD COPY useo: ssai-es-oes a
c.w
s s
v, 2/25/82 Chapter 15 Meeting 2/25/82 Richard Stark NRC Bethesda James Guppy BNL Upton, NY C. L. Allen NRC Bethesda Jerry Swift CRBR-NRC Bethesda Stephen Sands CRBR-NRC Bethesda John Hanson EG&G Bethesda Bob Copp EG&G Bethesda Tom Wehner Los Alamos Bethesda H. B. Holz NRC Bethesda CRBRP0 James C. Glynn NRC Research Mohsen Khatib-Rahbar BNL Upton, NY Lee Strawbridge W-ARP Waltz Mill Rob Woolley USD0E Germantown Paul Dickson W
Oak Ridge Ed Rodwell W
Oak Ridge Ralph Barrs LANL Los Alamos Erwin Schwegler LANL Los Alamos A. H. Spano NRC Bethesda R. A. Markley W
Madison, PA Charles R. Bell LANL Los Alamos, NM H. C. Huang W
Waltz Mill Jerry Mauck NRC-ICSB Bethesda Ernie Rossi NRC-ICSB Bethesda Bill Horak BNL Upton,:;NY _
Ashok K. Agrawal BNL Upton, NY Kenneth R. Perkins BNL Upton, NY Thomas B. Cochran NRDC D.C.
T. G. Schleiter USD0E Gennantown A. Macrae W
Waltz Mill Paul Boehnert NRC ACRS Wash. D.C.
Alden Bice NRC ACRS H. St., D.C.
John Long NRC RSB Bethesda Michael Tokar NRC CPB-Bethesda Peter Gross CRBRP0/D0E Oak Ridge Wayne Paska CRBRP0/D0E Oak Ridge Dan Ujifusa RRT DOE Gennantown Ambrose Schwa 111e Westinghouse ARD Waltz Mill Ronald Coffield W/ARD Waltz Mill Roger W. Tilbrook W/ARD Waltz Mill Milton Hoenig NRDC Wash. D.C.
Stephen Additon Westinghouse Bethesda Barbara Finamore NRDC Wash. D.C.
l l
i l
s 2/26/82 Chapter 15 Meeting 2/26/82 Richard Stark NRC Bethesda Rob Woolley DOE Germantown Lee Strawbrige Westinghouse Waltz Mill Ambrose Schwallis Westinghouse /ARD Waltz Mill Peter Gross CRBRP0/D0E Oak Ridge Paul Dickson W
Oak Ridge Mohsen Khatib-Rahbar BNL Upton, NY Ashok K. Agrawal BNL Upton, NY Ralph Baars LANL Los Alamos, NM Tom Wehner Los Alamos Bethesda Bob Markley WARD Madison, PA Charles Bell Los Alamos Los Alamos, NM H. C. Huang W
Waltz Mill J. L. Mauck NRC Bethesda J. G. Guppy BNL Upton, NY Bill Horak BNL Upton, NY K. R. Perkins BNL Upton, NY John Long NRC Bethesda T. G. Schleiter DOE Germantown Paul Boehnert NRC ACRS Wash. D.C.
Alden Bice NRC ACRS H. St., D.C.
i A. Macrae W/ARD Waltz Mill Neil W. Brown GE Bethesda Ron Coffield W/ARD Waltz Mill Roger Tilbrook W/ARD Waltz Mill Jerry Swift CRBRP0/NRC Bethesda David H. Moran CRBRP0/NRC Bethesda John Hanson EG&E/Bethesda Bethesda Bob Copp EG&G/Bethesda Bethesda H. B. Holz NRC CRBRP0 Erwin Schwegler Jr.
LANL Los Alamos James C. Glynn NRC
s
. cc:
Dr. Cadet H. Hand, Jr., Director Barbara A. Finamore Bodega Marine Laboratory S. Jacob Scherr University of California Ellyn R. Weiss P. O. Box 247 Dr. Thomas B. Cochran Bodega Bay, California 94923 Natural Resources Defense Council, Inc.
Daniel Swanson 1725 I Street, N.W.
Office of the Executive Suite 600 Legal Director Washington, D.C.
20006 U. S. Nuclear Regulatory Commission Eldon V. C. Greenberg Washington, D.C.
20555 Tuttle & Taylor 1901 L Street, N.W.
William B. Hubbard, Esq.
Suite 805 Assistant Attorney General Washington, D.C.
20036 State of Tennessee Office of the Attorney General L. Ribb 450 James Robertson Parkway LNR Associates Nashville, TN 37219 Nuclear Power Safety Consultants 8605 Grimsby Court William E. Lantrip, Esq.
Potonac, MD 20854 City Attorney Municipal Building P. O. Box 1 Oak Ridge, TN 37830 George L. Edgar, Esq.
Morgan, Lewis & Bockius 1800 M Street, N.W.
Washington, D.C.
20036 Herbert S. Sanger, Jr., Esq.
General Counsel Tennessee Valley Authority l
Knoxville, TN 37902 Chase Stephens, Chief Docketing and Service Section Office of the Secretary U. S. Nuclear Regulatory l
Connission Washington, D.C.
20555 Raymond L. Copeland Project Management Corp.
P. O. Box U Oak Ridge, Tennessee 37830 l
.s~
4 Distribution
. Docket Filev bcc: Applicant Service List
~NRC PDR Local PDR NSIC CRBRP0 File H. Denton D. Eisenhut R. Vollmer R. Mattson S. Hanauer H. Thompson J. P. Knight W. Johnston D. Muller P. Check W
~
R. W. Houston ff g
L. Rubenstein NECgfg..O F. Schroeder g
M. Ernst g
- g1 J
4 ACRS (16) 4 7
OI&E (3) i A3 S. Treby (0 ELD)
V. Moore g
B. Grimes R. Woodruff N
Region II Administrator
. ~..
ED0 (4)
L. S. Tong NRC Participants
- l J. A. Olshinski, Reg. II i
R. E. Ireland, NRC-Idaho J. Austin B. D. Liaw J. Glynn P. Wood Receptionist - Phillips Bldg.
CRBR Staff i
J. Long l
R. Jackson l
Charlie Thayer, Reactor Training Center, Chattanooga l
l l
1
-