ML20041E991

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Feb 1982
ML20041E991
Person / Time
Site: Salem 
Issue date: 03/10/1982
From: Miller L
Public Service Enterprise Group
To:
Shared Package
ML20041E987 List:
References
NUDOCS 8203160069
Download: ML20041E991 (11)


Text

e-AVERAGE DAILY UNIT FChE E.7.L DOCKET NO. 50-311 UNIT salem No. 2 DATE March 10, 1982 CCNPLETED BY L.

K. Miller TELEPHONE 609-541-5900X507 MONlli February 1982 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY P0ha EEL GWe-NET)

@BE-NET) 1 1,07) 17 1,119 2

1,073 18 1,134 3

1,154 19 752 4

1,050 20 502

,1 il 5

1,069 21 989 6

1,072 22 1,100 7

1,046 23 1,089 8

1,085 24 1,117 9

1,099 25 1,089 10 1,096 26 1,138

^

11 1,096 27 1,068 l

12 1,109 28 1,081 13 1,080

'9 14 1,119 30 15 1,108 31 i

16 1,107 l

Pg. 2 of 12 8.1-7. PJ.

r,203160069 820310 PDR ADOCK 05000311 R

PDR

e CFDATDC CAM IUPGC Doc m to.: 50-311 Dan :

March 10, 1982 Cnemn sy:

L. K. Miller MIDHmz: 609-541-5900X507 CypArnc 7:Mus A.

Unit Natus Sa1em No. 2 Notas:

3.

Reportirq Period February 1982 3.

Liounsed 2ar =1 Power Otit):

3411 4.

Nasuplate Ratirn (Gross fede):

1162 5.

Design U " m1 Ratirq (Not !tde):

1115 teav4== Dupendable spar-4ty ICms !tde):

1149 6.

r 7.

Paav4== Dupendable Capacity (Not ado):

1106 8.

Zf C)anges Occur in Capacity Ratirgs (Itman Nunter 3 S. rough 7) Since Iast Report, Give Reason:

None 9.

Power Imel Ib lt:1 cts Restricted, If Any (Not P9de):

None

10. Raascms For Restrictions, If Any N/A mis Ptmth Year to Data m eilative 672 1,416 3,337
12. taneer of Hours anactor was critical 668 1,412 3,271.3
13. Reactor Reserve Shut & wn Hours 0

0 0

H.

Hours Generator On-Line 666.1 1,405.8 3,223.5

15. Unit Reserve Shutdown Houra 0

0 0

16. Gross 2=r==1 Diergy Generated (.wn 2,182,846 4,421,816 9,529,835
17. Gross Electncal niergy Generatad(mi) 738,370 1,481,950 3,190,820
18. Not r.loctrit:a1 Energy Generatad0te) 710,686 1,424,583 3,056,650 l
19. Unit Servia ractor 99.1 99.3 96.6
30. anit Av=41-hi14ty Factor 99.1 99.3 96.6
21. 3dt capacity Factor (Usirn !<r Net) 95.6 91.0 82.8
22. Unit capacity ractor (Using DG Net) 94.8 90.2 82.2
23. Unit Torood Outage Rate

.9

.7 3.4

24. $hutzlowns S@adulad Over Next 6 femths (Type, Date, and Duration of Eacts):

None i

25. Zf Shut Down At End of Report Period,, Estimated Date of Starttp N/A
26. Units In Test Status (Prior to Cmunarcial Operation):

Icrecast Achie'ad INITIAL CR m CAL m 06/30/80 08/02/80 INMAL EI2ETRIcm 09/01/80 06/03/81 6-1-7.R2 Pg. 3 of 12 CD9GCIAL OPDATIm 09/24/81 10/13/81

/

tNIT rammxwas no toest sencrICNi DOCKET NO.:

50--311 sexoser nimi February 1982 t;mIT*NAnza Salem No. 2 DATE:

March 10, 1982 COMPI.ETED BY L. K. Miller TEt.Erasons: 609-541-5900X507 mmte or IURATICH GRHTIDC IJGPEE SY GDSOENT CMEIE NO NM so.

Ents Tyrs (irm)

M m

m Unm5 ACrICH 5)

I mactost aposer g PfuMNr DIDMetM3 82-056 1-24 F

0.0 A

4 HB ANNUNC High Steam Flow Alarms82-060 2-04 F

0.0 A

5 EA CKTBRK Crane Operator Caused Arc on 5015 Line Causing 5015 Line Breakers To Trip 82-062 2-08 F

0.0 A

5 HB ANNUNC High Steam Flow Alarms82-064 2-10 F

0.0 A

5 HF FILTER High Differential Pressure Circulating Water Traveling Screens Due To River Grass82-066 2-12 F

0.0 A

5 HH PUMPXX Low Suetion Pressure Steam Generator Feed Pump 82-068 2-12 F

0.0 A

5 HH PUMPXX Low Suction Pressure Steam Generator Feed Pump 1

2 3

4 5

F: Forced steason:

phthods Exhibit G - Instnactione g " bit 1-Sase si Sdueduled A-Rpipment Failure (Emplain) 1-Manual for Preparation of Data s-Maintenance or het Ehtry Sheets for Lloensee 2-Manual Scram.

Event pecortti a l File e-pefueling p-pegulatory poetricti m 3-Automatic Scram.

teamun-0161) a-operator Training a License nummination 4-Continuation of r-hhanistrative Previous Outage croperational ErrortSuplaint n-other (Belain) 5-Load Reduction 9-Other page 4 of 12

tml? samnes me roem macrians Docast iso.: 50-311 peroser mma February 1982 usert osane, Salen No. 2 l

Dats March 10, 1982 conPLETro at L. K. Miller Tet.gresong: 609-541-5900X507 l

ee:nnn w

taMRTIGE SENTIW.

LICEDGE ODEOWfr OREE NO GIf5WCrIVE eso.

twrt TrPE helms)

IW M D4 tool EVptr OEg5 acrgge go meson m u er s esevewr suousseux e

82-070 2-16 F

0.0 A

5 HA INSTRU 23 Governor Valve Swinging Due To Low Voltage Differential Transformer Electrical Spikes82-072 2-19 F

5.9 A

3 ED GENERA 22 Essential Controls Invertor Failed Causing Steam Generator Feed Pump Trip 82-074 2-22 F

0.0 A

5 HC PUMPXX Loss Of Vacuum Pump Seal Water Causing Condenser Back Pressure Creating Vacuum Loss On Turbine 82-076 2-25 F

0.0 A

5 HF FILTER 21B Circulator Out Of Service For Cleaning 82-078 2-26 F

0.0 A

5 HF FILTER 21A Circulator Tripped Due To High Differential Pressure On Screen 82-080 2-26 F

0.0 A

5 HF FILTER 21B Circulator Tripped Due To High Differential Pressure On Screen 82-082 2-26 F

0.0 A

5 HF FILTER 21B Circulator Tripped Due To High Differential Pressure On Screen 82-084 2-27 F

0.0 A

5 HF FILTER 21B Circulator Tripped Due To High Differential Pressure On Screen rage 5 of 12 s-1-7.nl

1 7

0 2

5 8

X 9

r 0

2 1

e 0

h h

l 9

g g

l 5

i i

o 0

i H n H n N

1 M

1 e

e 1

4 oe oe 1

m h

5 T r Tr 3

e c

K E

c c

l r

9 v

eS eS 2

i 0

a a

0 r

u u

e 5

S M

L 6

c g

D n D n E

E O

O W

W N 0s d

d s

1 l ee ee

: Y E U

E pr pr

.o E E B N 4

w M T O

OGN pu pu I

i s is A A D n NTr rs rs T M D E e C 3 T e Te f

T e EA s

M r

r T

E L S

acI L E e

rP rP R

o N P T N

f o

o D U M

C P

t l tl o

aa aa C

l i li ut ut c n cn re re i r ir C e C e f

f Af Bf 1i 1i 2D 2D r

ettS R

R E

oI E

E 2

T T

8 9

MG L

L 1

I I

G s

F F

tc yr as a

m u F

F r

m b H

H e e oF s

E 8

e m Et s

M f r a

3nr s M Ovo Es e

I s r L

e or m

u ms a u C

s s

n t

P s

8 I

o T

rT 0r a

0 mon 0r I

M m

A 5

5 e

S I

f A

A EG)

IS TR 0

0 N(O U

0 0

I I

I E PY F

F T

2 1

fo E

7 7

6l M

2 2

R.

D 7

2 2

g1a-r8 6

8 8

8 0

0

.0 8

2 2

8 8

DOCKET NO3 50-311 MAJOR PLANT MODIFICATIONS WIT NW:

Salem 2 REPORT MONTH FEBRUARY 1982 DATE:

March 10, 1982.

COMPLETED-BY:

L.

K. Miller TELEPHONE:

609-541-5900X507

  • DCR NO.

PRINCIPLE SYSTEM SUBJECT 2ET-1364 Steam Generator Perform steam genertitor moisture carry-over measurements 1

j l,

O l

l 1

l 4

O

  • DESIGN CHANGE REQUEST 8-1-7.R1 Page 7 of 12 e

--r-9-m w---

,.w-n, e- - - =

e.

--m-e-,

f DOCKET NO.:

50-311 MAJOR PLANT MODIFICATIONS UNIT NAME:

salem No. 2 REPORT MONTH February 1982 JATE:

March 10, 1982 COMPLETED BY:

L. K. Miller TELEPHONE:

609-541-5900X507

  • DCR NO.

10CFR50.59 SAFETY EVALUATION 2ET-1364 This DCR does not affect the safe shutdown of the reactor plant and a change to the technical specification or SAR is not required.

1

  • DESIGN CHANGE REQUEST Page 8 of 12

[

t j

b b

90)fFD Ry qaLFM GFNFkaffAn 91aff0N DalF 09/09/AD nEDa#T"EMT, 400K OOnFR Nn.

Satrfv o[taTFn rouleurs? woog poorw LOG - It'ITT 7 PaGF On01 WOWE nRnER NU"RER nEpf EOUTP*ENT InEMitFTCaffnu rupt amat tog r.F nnpw PE*FnRwEn s

CCA0ml u

avv DCP Re:S nESC#1pTTnN nF PenmLFM, PEOFnRw f/n 706597 CnRRECTivF arTInN, aLL "U9E9 Da93Fn TFST C87C70 M

VALVE,274MIA8 nE*CDISTTOM OF PDnatrM, TE"PnRauf RFPafR T/ VALVE,2*MM168 CnROECTTyr ar. finn, parnfwG a R04Nrf SFatEn RT FifRMANITE (8'213 w

VALVE.23M91AT nE9ColpTT04 nF Po RLFM, MYnpayLIr STS V/s.0w nN OTL n

CnapFCTfvF arTION, OEFILL 4 RFPIarE SfGMT Gl. 4 95 j

C8 2A8 4

COMPRFSM00,724 97ARTIwG afe l

OESC#IpTf0N nF po nLFM, "0709 RUDNFD n

CP7#ECTivr acting, orplaCFD COMPRFS900 WOT08 C26tof o

Nn.7I S/G FOwfR F104 CONTout nE9t#1pTT04 nF pon*LFM, CON T ont PRDRLEMS, 9/C FDwip FLnw CnHDErityr art!ny, oEPL #FLaf Fr510a. SpIMING STOOPFD C;soTI p

Nn.3 oRIMARY WTD TNK nE9CDIPTinM OF PanRLFM, IEvFL TNntrafinN F907EN CnpoErftvF ACTION, Thaw LINF/ WFPtArE LAGGING C37318 p

Cngfunt unD wf THn#aWal iIWIT "E9CDI*Tinn nr po pLFM, LHMS or POSIf tvE Mn0FWaTnd CnEFFTCTENT n

CnHOFrTivr arYIn*a, rHe 90n w!THnWannt LfMit Page 9 of 12

COWTFD Ry SatrM nr%FusTThC 9TaTTON DalF 01/ng/gp DE#ADTuENT, WO*w O'DFR Nn.

34FFTv OFIATFn r stipur%T wpog gjotir g LOG. tlMIT p PaGF onnD u

w0#2 ORnED NUwere NEST E ntlT P"E NT InENTTFTCATTn" FIPLANATTOW nF nneu DEspnR*Fn C84254 NTS N95 DFCnRnER nEMC#IPTTON OF PDnplFM, PENS 1 4/#EADTNG PROPFRLT CARDEPTTvF arTInN, WOVE CaRLE Bt'NnLF 4 #EC AI C8%518 9

RnD CnNTRnl SYS nESC*IPTTON OF P#n#LFM, 90n ItRCENT FaILU#E AtAe4 CnRgECTTyr ArTION, DE*LACF FilSt/CTRCUTT BnAoD CR;5%3 p

RMS CH2941A nEMC#IpTTON OF PUnRLFM, WILL N/ SCAN. PitMP DUT OF SPEr.

CnRoECTTvF arTInN, oEPL RaTTERIFS. Fil*CTInNat TFST SAT CC1366 21 *G FFEn FLnn DEMC#IPTT04 tiF PDnRLrM, OHaNNFt. DUT OF SPEC.

C"R#ErTTvF arTION,

  1. EPLACFD Sn NT MnDitLF, 2FM9108 CC11AR p

guS STS CHANNFL 2OI1A

'l BE9ColpTT04 DF pen trM.

OEMPMN9E nHT nr *PFC.

e d

Cn##ErTTvr arfinN, DErai/pF9ET nItC#IMINAT0o vnt TacF QQ1bE9 p

RuS CHANNFL 2016 nggColpTT04 DF POnRLFM, BETEtine nati nF 9PFC Cn8DFrffvF ArTION, EFPL COY 9 fat, pH TilBr 4 oECALImp4TF 9C4T03 p

Op. OFLTA T Lnno p1 DE*CDIPTTnM OF PpnRLFW, AP DFLTA T FAIIEn WICH, innP 21 CoppFrTTyr ACTION, OFpt c apar t isjo%/ ras.IngaTr ATwS12F

- l l

TOTAL LIwE9

  • Oinnep i

TOTAL 4-DEPS = onente t

LAST UPDaTr cansn9 12%700 Page 10 of 12 I

f' 3

s'

,Y e

r

./

/ i

  1. SALEM UNIT 2 OPERATING

SUMMARY

REPORT f,'t FEBRUARY 1982 1

R

+

2-04-82

,- 1600

. Reducing load due to loss of transmission t

'line.

Load increased to normal with line back in service.

f v

2-06-82 0030 Reducing load to 92% RTP for turbine valve test.

2-07-82 1635 Collected state point data to monitor I

high steam flow condition.

2-12-83

%2030,.

Low feed pump suction pressure.

Power

,f.

\\

reduced from %100% to %98%..

4

p. e 2-13-82 0200 Power
  • reduced to %93% for turbine over-

/

speed test.

r

r.

s, 2-16-82

'N0900 Power reduced to N95% due to fluctuation of governor valve on main turbine.

Problem corrected and power increased to

%100% by 1100 hours0.0127 days <br />0.306 hours <br />0.00182 weeks <br />4.1855e-4 months <br />.,

2-19-82 Rx trip at 1624, hours due to failure of inverter power supply'ho feed pump.

> Reactor #critica'l at 2030 hours0.0235 days <br />0.564 hours <br />0.00336 weeks <br />7.72415e-4 months <br />.

Unit Ion ling at 2217.

\\

c 2-22-82 Reduce ^d' power at %1500 hours to 85%'due to loss of condenser vacuum.

(Loss'of

' vacuum pump seal).

Back up to 100%

power by %2100 hours.

2-26-82

%0500 hours power reduced to %90% due to loss of'circulatoy screen.

Power back f.

to~N100% by 0800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br />..

>2-2 7-82._

NPower red' iced to %80% and later 70%, due

[

to loss of circulating water.

Circulating s

(.

water screens clogged with grass.

~

~~' '

2228-82 Power at 100%.

'9 N

\\

'*m i

(.

  • [ -

,j',

s

~,

,s 3'

age 11 of ?2

)

- e8

REFUELING INFORMATION DOCKET NO.:

50-311 UNIT:

Salem No. 2 DATE:

March 10, 1982 COMPLETED BY:

L.

K.

Miller TET.EPHONE : 609-541-5900X507 MONTH:

February 1982 1.

Refueling information has changed from last month:

YES X

NO 2.

Scheduled date of next refueling:

January 22, 1983 3.

Scheduled date for restart following refueling:

Anril 24, 1993 4.

A.

Will Technical Specification changes or other license amendments be required?

YES NO NOT DETERMINED TO-DATE February 1982 B.

Has the reload fuel design been reviewed by the StatAon Operating Review Committee?

YES NO X

If no, when is it scheduled?

December 1982 5.

Scheduled date(s) for submitting proposed licensing action:

December 1982 (If Required) 6.

Important licensing censiderations associated with refueling:

7.

Number of Fuel Assemblies:

A.

In-Core 193 0

B.

In Spent Fuel Storage 8.

Present licensed spent fuel storage capacity:

1170 Future spent fuel storage capacity:

1170 9.

Date of last refueling that can be discharged to the spent fuel pool assuming the present licensed capacity:

March 2000 Page 12 of 12 8-1-7.R4

-