3/3/2016 NRC:HealthPhysicsPositionsProposedGuidanceforCalibrationandSurveillanceRequirementstoMeetItemII.F.1ofNUREG0737 http://www.nrc.gov/aboutnrc/radiation/protectsyou/hppos/hppos001.html 1/2 Home>AboutNRC>RadiationProtection>HowNRCProtectsYou>HealthPhysicsPositionsBasedon 10CFRPart20 ProposedGuidanceforCalibrationandSurveillance RequirementstoMeetItemII.F.1ofNUREG0737 HPPOS001PDR9111210074 SeethememorandumfromD.G.EisenhuttoRegionalAdministratorsdatedAugust16,1982.Thismemo includes"ProposedGuidanceforCalibrationandSurveillanceRequirementsforEquipmentProvidedto MeetItemII.F.1,"preparedbytheDivisionofSystemsIntegration,NRR.
PresentedbelowisabriefdescriptionoftheProposedGuidance.Itisstronglyrecommendedthattheentire documentbereviewed.Thehealthphysicspositionwaswritteninthecontextof10CFR20.201,butitalso appliesto"new"10CFR20.1501(a)and20.1501(b).
Thenoblegaseffluentmonitors,particulateandradioiodinesamplers,andincontainmentradiation monitorsdescribedinNUREG0737,ItemII.F.1,Attachments1,2,and3,aresubstantialdeparturesfrom conventionaldesignsandoperatingconceptsindetectingandmeasuringplantradiologicalconditions.The natureandpurposeofthesemonitorsandsamplersdictatesanapproachtocalibrationandsurveillance requirementsthatdifferswidelyfromexistingrequirementsandproceduresestablishedforconventional monitors.Theproposedguidanceaddressesconcernsrelativetoreviewoflicenseesimplementing proceduresandprovidesguidanceoncertainmatterspertainingtocalibration.
APPLICATIONOFANSIN3231978:
ANSIN3231978Recommendationsasrequirementsforthereviewoffixedareaandeffluentmonitorsare notappropriateforeithernormalrangeorNUREG0737monitors.ThestandardscontainedinANSIN323 1978specificallyaddresshandportablesurveyinstrumentationandarenotapplicabletofixedareaor effluentmonitors.
MC2515,INSPECTIONPROCEDURE84710:
MC2515,InspectionProcedure84710waswrittenspecificallyformonitorsdesignedtooperateatverylow concentrationsofradioactivematerialsandisnotappropriateforuseinconjunctionwithNUREG0737 noblegaseffluentmonitorsforthefollowingreasons:(1)ALARAconsiderationslimitthehandlingof gammaemittingnoblegasesinconcentrationssufficienttoperformonsiteupperrangecalibrationofthese monitors(2)InspectionProcedure84710suggestsusingKr85,agasnotsuitableforcalibrationofmost NUREG0737effluentmonitors(3)theonlypracticablemeansofinplacecalibrationofNUREG0737 effluentmonitorsintheupperranges,"solid"sources,isnotconsistentwith84710and(4)releaseof calibrationgasestotheenvironmentaftercalibrationcouldresultinviolationsofplantTechnical Specifications.
NRRSTAFFRECOMMENDATIONSFORCALIBRATIONOFNOBLEGAS EFFLUENTMONITORS:
Anacceptableapproachcallsforaonetime"type"calibrationofalimitednumberofproductionmodel monitorsusingradioactivegases,anacceptablealternativetoinplacetestingwithradioactivegasesdueto
3/3/2016 NRC:HealthPhysicsPositionsProposedGuidanceforCalibrationandSurveillanceRequirementstoMeetItemII.F.1ofNUREG0737 http://www.nrc.gov/aboutnrc/radiation/protectsyou/hppos/hppos001.html 2/2 ALARAconsiderations.Thecalibration,ateitherthemanufacturer'sfacilityorsuitablecontractorfacility, woulduseNBStraceableradioactivegassourcesoftheappropriateemissivecharacteristicsataminimum ofthreeonscalevaluesseparatedbynotlessthantwodecadesofscale.Oneormore"LaboratoryStandard Sources"couldbeestablishedusingsolidradioactivesourcematerialhavingemissiveradiation characteristicssimilartothoseofthecalibrationgas.Thesolidsourcescouldthenbeusedtodevelop "SecondaryCalibrationSources"usedforonsiteinplacecalibration.Itissuggestedthatperiodic confirmationorverificationofcalibrationsourcevaluesbemadeapartofsurveillanceprocedures.
INCONTAINMENTHIGHRANGERADIATIONMONITORS:
NRRrecommendsthatlicenseesverifymonitordesigncharacteristicsbyrequiringtypetestingatsufficient pointstodemonstratelinearitythroughallscalesupto106R/hr.Inaddition,licenseesshouldspecifythat eachproductiondetectorbetestedat103R/hrtoassuresatisfactoryresponsetohighlevelsofradiation.
PARTICULATEANDRADIOIODINESAMPLINGFROMEFFLUENTGAS STREAMS:
NRRwouldacceptempiricaldataonsamplinglinelossesbasedonactualtestsofeithertheinstalledsystem orafullscalemockupinlieuofcalculationsbasedonANSIN13.11969appendices.
NRRrecommendsOIEreviseMC2515,InspectionProcedure84710orconsiderpreparationofaseparate inspectionprocedureortemporaryinstructionforNUREG0737items.Thesuggestedguidancein NUREG0737andthismemorandumwithitsattachmentsshouldprovidethebasistoinitiateaction.
Regulatoryreferences:10CFR20.201,10CFR20.1501,NUREG0737,TechnicalSpecifications Subjectcodes:6.4,7.3,12.16 Applicability:Reactors PageLastReviewed/UpdatedThursday,June04,2015