February 18, 2020 U.S. Nuclear Regulatory Commission Public Meeting Summary
Title:
Steam Generator Task Force Meeting Meeting Identifier: 20200012 Date of Meeting: January 22, 2020 Location: OWFN 12B04 Type of Meeting: Category 2 Purpose of the Meeting: The purpose of this meeting is for the NRC staff to discuss steam generator (SG) issues with the industry.
General Details: The industrys Steam Generator Task Force (SGTF) met with U.S. Nuclear Regulatory Commission (NRC) staff on January 22, 2020, at NRC headquarters. The purpose of the meeting was to discuss proposed changes to SG technical specifications. The industry meeting slides are available in the Agencywide Documents Access and Management System (ADAMS) under Accession No. ML20022A361. This meeting was noticed as a public meeting and the agenda is available in ADAMS under Accession No. ML20006E430.
LISTING OF ATTENDEES STEAM GENERATOR TASK FORCE MEETING November 14, 2019 PARTICIPANTS Daniel Mayes Steve Brown Helen Cothron Lee Friant Jeremy Mayo Steven Bloom Alan Huynh Allen Hiser Andrew Johnson Paul Klein Gregory Makar Ching Ng Pat Purtscher Leslie Terry Entergy EPRI Exelon TVA NRC NRC NRC NRC NRC NRC NRC NRC NRC NRC PHONE PARTICIPANTS Brent Capell Brian Mann Mike OKeefe Kester Thompson Russell Cipolla William Cullen Sean Kil EPRI EXCEL Services Certrec NextEra Intertek Intertek EPRI AFFILIATIONS Duke Energy Summary of Presentations: During the meeting, industry representatives made presentations which addressed topics described in the meeting notice. At various points in the meeting, there were additional discussions about agenda topics. A summary of the information exchanged during the meeting is discussed below. Unless noted otherwise, the information below was stated by industry representatives.
During the November 14, 2019, SGTF meeting (ADAMS Accession No. ML19344A876),
members of industry and NRC staff discussed a potential approach to modify the steam generator (SG) technical specifications (TSs) within the framework of the existing performance-based TSs. Members of industry are proposing to use this approach to submit a Technical Specification Task Force (TSTF) Traveler for NRC staff review.
The industrys proposal would increase the maximum interval between inspections to 72 and 96 effective full power months for SGs with thermally-treated Alloy 600 and thermally-treated Alloy 690 tubing, respectively. The proposal would also retain a requirement for SG tube inspections following an inspection in which crack indications are identified.
The NRC staff and industry will meet again on February 24, 2020, to discuss the technical aspects of the proposal. The industry will compile and present data to support an increased operating interval between SG tube inspections.