ML20041D768

From kanterella
Jump to navigation Jump to search

Submits Correction to Util Re NUREG-0737,Item II.K.2.13, Thermal-Mechanical Rept - Effect of HPI on Vessel Integrity for Small Break LOCA W/No Auxiliary Feedwater
ML20041D768
Person / Time
Site: Davis Besse 
Issue date: 03/03/1982
From: Crouse R
TOLEDO EDISON CO.
To: Stolz J
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-2.K.2.13, TASK-TM 790, TAC-45198, NUDOCS 8203090160
Download: ML20041D768 (1)


Text

Docket No. 50-346 TOLEDO EDISON License No. NPF-3 nnwep

>o Serial No. 790 p.-

(o March 3, 1982 d

!)?.,,

Q c,ffr S*E;)

L Director of Nuclear Reactor Regulation J

082g Attention:

Mr. John F. Stolz l

p:/6.

/

Operating Reactors Branch No. 4 Division of Operating Reactors ssp United States Nuclear Regulatory Commission I h,N '

Washington, D.C.

20555

Dear Mr. Stolz:

Toledo Edison has identified an inadvertent typographic error in our submittal dated February 25, 1982 (Serial No. 786).

We would like to bring to your attention that the following discussion supersedes the one in the submittal as mentioned above.

This is to respond to your questions in the letter to all B&W reactor plants dated January 4, 1982 concerning our submittal for NUREG-0737, Item II.K.2.13 " Thermal Mechanical Report - Ef fect of HPI on Vessel Integrity for SBLOCA with no AFW."

Toledo Edison has made a submittal on May 22, 1981 (letter Serial No.

718) outlining the features of Davis-Besse #1 to identify that the reactor vessel thermal shock issue is not a concern requiring immediate remedial action for our facility.

Since that time, B&W has performed a specific analysis for Davis-Besse #1 using the general approach as described in BAW-1628.

It was concluded that, for at least the first 6 EFPY of operation, a 0.023 ft.2 Small Break Loss of Coolant Accident, with loss of auxiliary feedwater and no b

operator action to throttle HPI, will not lead to brittle fracture of our vessel.

This is the worst limiting case identified to date.

As a result. Toledo Edison has no need to establish procedures to instruct operators to throttic HPI and maintain 100 F subcooling margin following a SBLOCA with no auxiliary feedwater. Therefore, no training has been conducted to familiarize our operators with such operations.

/CO'l f J Very truly yours, f

2 r

RPC:FYC: sic cc:

DB-1 NRC Resident Inspector THE TOLEDO EDISON COMPANY EDISON PLAZA 300 MADISON AVENUE TOLEDD, OHIO 43652

@203090160 820303 PDR ADOCK 05000346 P

PDR