ML20041D396

From kanterella
Jump to navigation Jump to search
Responds to NRC 820126 Request for Info on Effects of Single Failure Assumptions on App K Evaluation Model for Large Break ECCS Analyses.No Single Failure May Be Conservative Assumption.Info Will Be Submitted by 820319
ML20041D396
Person / Time
Site: Yankee Rowe, Maine Yankee, 05000000
Issue date: 02/26/1982
From: Kay J
YANKEE ATOMIC ELECTRIC CO.
To: Speis T
Office of Nuclear Reactor Regulation
References
FYR-82-24, NUDOCS 8203050290
Download: ML20041D396 (1)


Text

YANKEE ATOMIC ELECTRIC COMPANY

.- Q~

M

\\~h 1671 Worcester Road, framingham, Massachusetts 01701

.YANKEM 2.C.2.1 FYR 82-24

~

v-ms c.

RECmna 9-

"g 0 41982w a

February 26, 1982

(

p United States Nuclear Regulatory Commission Wa shing ton, D. C. 20555 Attention:

Mr. Themis P. Spels, Assistant Director for Reactor Safety Division of Systems Integration Re f e re nc es :

(a) License No. DPR-3 (Docket No. 50-29)

( b) License No. DPR-36 (Docket No. 50-309)

(c) Le t t e r, Themis P. Speis (USNRC) to D. E. Vandenburgh (YAEC),

dated Janua ry 26, 1982 Su bj ec t :

Yankee Large Break Appendix K Evaluation Model

Dear Sir :

Ref erence (c) requested information on the ef fects of single failure assumptions (e.g., loss of one low head safety injection pump) on the Yankee approved Appendix K evaluation model for large break ECCS analyses.

For this analyses, it has been identified by Westinghouse that no single failure may be the conservative assumption.

This information is currently being prepared and will be submitted by Ma rch 19, 1982.

If you have any questions, please contact us.

Very truly yours, YANKEE ATCMIC ELECTRIC COMPANY 4.

J. A. Kay Senior Engineer - Licensing JAK: dad i0 8203050290 820226 PDR ADOCK 05000029 P