l Implementing Procedures (VY Emergency Plan)
February 11, 1982
(..mnge #8
- Instructions -
1.
Under the tab " Unusual Event" incorporate DI 82-1 into the procedure
.j nu.ubered 0.P. 3500, Rev. 1.
2.
Under the tab " Alert" incorporate DI 82-2 into the procedure numbered 0.P. 3501, Rev. 2.
i 3.
Under the tab " Site Area Emergency" incorporate DI 82-3 into the procedure numbered 0.P. 3502, Rev. 13.
)
4 Under the tab " General Emergency" incorporate DI 82-4 into the i
procedure numbered 0.P. 3503, Rev. 4.
i 1
d J
9 9
W m 8203040463 820225 PDR ADOCK 05000271 I
F PDR
.a:
MEMORANDUM f//[2 To Plant Procedure Manual Holders Vernon f-
.b. /_
u,/
v Vernon pitg 6.1.5 FRoM_
SU2 JECT Chanze to Plant Procedure Manual s8/
DEPARTMENT INSTRUCTION _Tir f&/
1, o (JVdS SA i Date: t/9/s L Concurring Individual:
2 V
I SRO Concurring:
O2 b
Date: 1/9 SA Ort / Mt2
.1/r//'
Date:
Second SRO Concurring:
Chemistry and Health Phy Kes Supervisor or Plant Health Physicist:
Date:
This instruction becomes effective on the date that a Second Senior Licensed Operator signs above, unless a Health Physics procedure is involved, in which case this instruction becomes effective on the date that a Senior Licensed Operator and the Chemistry and Health Physics Supervisor or the Plant Health Physicist signs above.
Instruction Cancelled:
Rev.
E of /)/' 3.@/j Scope o Instructic :
&nh.!
. k
.Lc0 Reason for Change:
vu P Reviewed Mdh 4 frrt)
Approved h A tr.pm FORC f cretarf
- lantManagi.g i
i A.P. 0832, Figure 1 Rev. 7
0.P. 3500 s
DI #82-1 APPENDIX I UNUSUAL EVENT - SHIFT SUPERVISOR / PLANT EMERGENCY DIRECTOR Immediate Actions:
' Time / Initials 1.
Conditions have been assessed and the applicable Emergency Operating Procedure is utilized.
2.
The type of emergency (Unusual Event) has been determined from 0.P. 3125, Classification of Emergencies.
/
3.
Determine immediate personnel response to be taken.
4.
Turn the Page System Volume Increase Switch to the-
" Alert" position, turn the Alarm Switch to the "0N" position for ten seconds, and then announce the following over the Plant Paging System:
a.
" Unusual Event, Unusual Event, Unusual Event" b.
There is (what) in/at (where) c.
The following personnel (as determined in Step 3) report to (where). All other personnel stay clear of the area"
/
5.
Request the Shif t Technical Advisor to report to the Control Room and provide assistance.
/
6.
Notify the NRC on the NRC Emergency Notification System red phone. Maintain an open, continuous com=unications channel on this line.
/
7.
a.
Notify the New Hampshire, Massachusetts, and Vermont State Police Agencies by depressing number 111 on the Nuclear Alert System orange phone (or utilizing telephone backup) and making the following announcement upon establishing communications:
"This is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have an Unusual Event. I repeat, this is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have an Unusual Event. Please ac-knowledge with your name, your state, and a repeti-tion of the message."
Vermont Name of Dispatcher N.H.
Name of Dispatcher Mass.
Name of Dispatcher Page 1 of 3
. - _ _ -. _ _ _ _ =--= ---- ~..-n
0.P. 3500 DI #82-1 APPENDIX I (Continued)
Time / Initials b.
As soon as the initial message (Step 7a) has a
been acknowledged by all the Vermont, New Hampshire and Massachusetts State Police, hang up.
Make a subsequent notification to the Vermont State Police by depressing 213 on the Nuclear Alert phone and provide the following statements:
1.
"This is Vermont Yankee Nuclear Power Station";
2.
"We have declared (indicate the emergency class) because (indicate the initiating condition per 0.P. 3125)";
3.
"The plant is (pick one) a.
continuing normal operation, b.
reducing present power levels, or c.
shutdown";
4.
"A release (pick one) a.
is anticipated, b.
is in progress, or is not expected to occur as a result of c.
present accident conditions.";
5.
"Present meteorological conditions indicate (provide wind speed and direction)",
6.
"At the present time we recommend (pick one) a.
no protective action, or b.
that the general public be advised to seek shelter until further notified." (Use b.
for General Emergency Classes.)
7.
"I repeat, this is Vermont Yankee Nuclear Power Station. Please acknowledge with your name."
Vermont l-Name of Dispatcher Expect calls from State Health and/or C.D.
c.
Officials concerning plant conditions.
l 8.
Notify the Security Shift Supervisor to activate the telephone paging system. Advise him, at this time,yof the paged individuals required to report to the plant site.
/
Page 2 of 3
-___.,_,__---,mm
0.P. 3500 DI #82-1 p
APPENDIX I (Continued)
Time / Initials 9.
When contacted by the Emergency Operations Facility Coordinator, advise him of classification and event
/
conditions.
10.
Direct activities of emergency response personnel until overall responsibility is assumed by the Technical Support Center Coordinator.
11.
Request assistance of outside agencies (fire, law enforcement, or medical rescue personnel and related equipment) as needed to deal with the event.
/
a.
Fire b.
Medical
/
c.
Law Enforcement (in conjunction with the Security Shift Supervisor)
/
Subsequent Actions:
1.
Changing conditions may require escalation of emergency classification to a more severe condition.
Assess conditions periodically and be prepared to initiate this escalation.
SE 2.
In concert with the T.S.C. Coordinator, provide information to assist with the final closecut of the emergency Unusual Event condition.
Final Conditions:
1.
When the Unusual Event conditions no longer exist, announce on the plant page system that the Unusual Event is ended.
/
2.
Summarize all actions and resultant conditions in the Shift Supervisor's Log.
+
Page 3 of 3 1.
e
...c.__..-==--+_,eme-m-mw m...
~
.a s MEMORANDUM
[I f /ff[,
To Plant Procedure Manual Holders Vernon FROM 34% /
ernon FILE 6.1.5 SUCJECT ChanRe to Plant Procedure Manual
/
- ///
DEPARTMENT INSTRUCTION 71f2.
m Date: 1/9/47 Concurring Individual: @d b A/7!2k SRO Concurring:
h ha Date:
dh 2-a Date:
Second SRO Concurring:
~
Chemistry and Health Physics Supervisor or Plant Health Physicist:
Date:
This instruction becomes effective on the date that a Second Senior Licensed Operator signs above, unless a Health Physics procedure is involved, in which case this instruction becomes effective on the date that a Senior Licensed Operator and the Chemistry and Health Physics Supervisor or the Plant Health Physicist signs above.
CP Instruction Cancelled:
Rev.
3 of M O/
Scoce of Instruction:
hh 510 N#
M l-Reason for Change:
~'
U v0.0 Reviewed //
J #72f Approved d MM
'POK Secretdry fiantManagep A.P. 0832, Figure 1 Rev. 7
~
,._.1
am M u p.s a
=wW e
0 0.P. 3501 DI #82-2 APPENDIX I ALERT - SHIFT SUPERVISOR / PLANT DfERGENCY DIRECTOR Time Initials Immediate Actions:
1.
Conditions have been assessed and the applicable Emergency Operating Procedure is utilized.
2.
The type of emergency (Alert) has been determined from A.P. 3125, Classification of Emergencies.
3.
Determine the immediate personnel response to be
- taken, 4.
Turn the Page System Volume Increase Switch to 1
the "0N" position for ten seconds, and then j
the " Alert" position, turn the Alarm Switch to announce the following over the plant paging system
- I a.
" Alert, Alert, Alert" b.
"There is (what) in/at (where)."
c.
" Emergency personnel report to the Technical Support Center, the Operations Support Center, and the Emergency Operations Facility as required.
All other personnel and contractors return to your department area and await further instructions. All visitors return to Governor Hunt House Information Center. All personnel stay clear of the affected area."
5.
Request that the Shift Technical Advisor report to the Control Room and provide assistance.
6.
Notify the NRC on the NRC Emergency Notification System red phone. Maintain an open, continuous communications channel on the line.
7.
a.
Notify the New Hampshire, Massachusetts, and Vermont State Police Agencies by depressing number 111 on the Nuclear Alert System orange phone (or utilizing g-telephone backup) and making the following announcement upon establishing communications:
"This is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have an Alert. I repeat, this is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have an Alert. Please acknowledge with your name, your state, and a repetition of the message."
l Page 1 of 3
,.. ~
0.P. 3501 APPENDIX I (Continusd)
DI #82-2 Time Initial Vermont Name of Dispatcher N.H.
Name of Dispatcher Mass.
Name of Dispatcher b.
As soon as the initial message (Step 7a.) has been acknowledged by all the Vermont, New Hampshire and Massachusetts State Police, hang up.
Make a subsequent notification of the Vermont. State Police by depressing 213 on the Nuclear Alert phone and provide the following statements:
1.
"This is Vermont Yankee Nuclear Power Station";
2.
"We have declared (indicate the emergency class) because (indicate the initiating condition per 0.P. 3125)";
3.
"The plant is (pick one) a.
continuing normal operation, b.
reducing present power levels, or c.
shutdown";
4.
"A release (pick one) a.
is anticipated, b.
is in progress, or c.
is not expected to occur as a result of present accident conditions.";
5.
"Present meteorological conditions indicate (provide wind speed and direction)";
6.
"At the present time we recommend (pick one) a.
no protective action, or b.
that the general public be advised to seek shelter until further notified." (Use b.
for General Emergency Classes.)
7.
"I repeat, this is Vermont Yankee Nuclear Power Station. Please acknowledge with your name."
Vermont Name of Dispatcher j
u l
l Page 2 of 3
.,)
~_.
O.P. 3501 APPENDIX I (Continued)
DI #82-2 Time Initial Expect calls from State Health and/or C.D.
c.
Officials concerning plant conditions.
8.
Notify the Security Shift Supervisor to activate the. telephone paging system for plant personnel and Yankee NSD personnel.
9.
When contacted by the Emergency Operations Facility Coordinator advise him of the classification and event conditions.
10.
Direct the activities of the emergency response personnel until overall responsibility is assumed -
by the Technical Support Center Coordinator.
11.
Request assistance of outside agencies (fire, law enforcement, or medical rescue personnel and related equipment) as needed to deal with the alert event.
a.
Fire b.
Medical c.
Law Enforcement (in conjunction with the Security Shift Supervisor)
Subsequent Actions:
1.
Changing conditions may require escalation of emergency classification to a more severe condition.
Assess conditions periodically and be prepared to initiate this escalation in concert with the T.S.C. Coordinator 0g 2.
In concert with the T.S.C. Coordinator, proside information to assist with the final closeout of the emergency Alert condition.
Final Conditions:
1.
When the Alert conditions no longer exist, announce on the plant page system that the Alert is ended.
I t
2.
Summarize all actions and resultant conditions in the Shift Supervisor's Log, i
Page 3 of 3
i I
MEMORANDUM 9,'f[/
o Plant Procedure Manual Holders Vernon
$ L t'/ n 2.
Vernon FILE 6.1.5
_ROM Chanze/
to Plant Procedure Manual iUOJECT N'd f ns,,I/M DEPARniENT INSTRUCTION Date:
- 2. [ 9 [ $2,L Concurring Individual:
2[9!82 SRO Concurring:
O u Jo. t4 Date:
0(([ $
S/f//L Date:
Second SRO Concurring:
v -
yv Chemistry and Health Physics Supervisor or Plant Health Physicist:
Date:
This instruction becomes effective on the date that a Second Senior Licensed Operator signs above, unless a Health Physics procedure is involved, in which case this instruction becomes ef fective on the date that a Senior Licensed Operator and the Chemistry and Health Physics Supervisor or the Plant Health Physicist signs above.
Instruction Cancelled:
Rev.
/[
of d[ 8S 2.,
Scope of Instruction:
}
&w ph _f.
Ab C
Reason for Change:
M '?LC Revie..ied M3h. [ / 7d Approved
[U/2/h PORffSecretiry Plant Manage:(/
l 1
A.P. 0832, Figure 1 Rev. 7 e mae
.e.e.s
0.P. 3502 s
DI #82-3 APPENDIX I SITE AREA - SHIFT SUPERVISOR / PLANT EMERGENCY DIRECTOR Time-Initials Immediate Actions:
1.
Conditions have been assessed and the applicable Emergency Operating Procedures are utilized.
If a release is in progress, refer to 0.P. 3513
" Evaluation of Radiological Conditions."
2.
The type of emergency (Site Area) has been determined from A.P. 3125, Classification of Emergencies.
3.
Determine the immediate personnel response to be taken.
4.
Turn the Page System Volume Increase Switch to the
" Evacuation" position, turn the Alarm Switch to the "0N" position for fifteen seconds, and then announce the following over the Plant Paging System:
" Site Area Emergency, Site Area Emergency, a.
Site Area Emergency" b.
"There is (what) in/at (where)."
" Emergency response personnel report to l
c.
the Technical Support Center, the Operations Support Center, and the Emergency Operations Facility as required. All other personnel, visitors, and contractors report to the Governor Hunt House Information Center" 5.
Notify the Shif t Technical Advisor to report to the Control Room and provide assistance.
6.
Notify the NRC on the NRC Emergency Notification System red phone. Maintain an open, continuous communications channel on this line.
i Notify the New Hampshire, Massachusetts, and Vermont
~
7.
a.
State Police Agencies by depressing number 111 on che Nuclear Alert System orange phone (or utilizing telephone backup) and making the following announcement upon establishing communications:
"This is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have a Site Area Emergency.
I repeat, this is Vermont Yankee Nuc.'zwar Power Station in Vernon, Vermont. We have a Site Area E=ergency, please acknowledge with your name, l
l your state, and a repetition of the message."
Page 1 of 3
0.P. 3502 APPENDIX X (Continued)
DI #82-3 Time Initial Vermont Name of Dispatcher N.H.
Name of Dispatcher MMss.
Name of Dispatcher b.
As soon as the initial message (Step 7a.) has been acknowledged by all the Vermont, New Hampshire and Massachusetts State Police, hang up.
Make a subsequent notification of the Vermont. State Police by depressing 213 on the Nuclear Alert phone and provide the following statements:
1.
"This is Vermont Yankee Nuclear Power Station";
~
2.
"L'e have declared (indicate the emergency class) because (indicate the initiating condition per 0.P. 3125)";
3.
"The plant is (pick one) a.
continuing normal operation, b.
reducing present power levels, or c.
shutdown";
4 "A release (pick one) a.
is anticipated, b.
is in progress, or is not expected to occur as a result of c.
present accident conditions.";
5.
"Present meteorological conditions indicate (provide wind speed and direction)";
6.
"At the present time we recommend (pick one)
J.
a.
no protective action, or b,
that the general public be advised to seek shelter until further notified." (Use b.
for General Emergency Classes.)
7.
"I repeat, this is Vermont Yankee Nuclear Power Station. Please acknowledge with your name."
j' Vermont Name of Dispatcher u
Page 2 of 3
0.P. 3502 APPENDIX I (Continued)
DI #82-3 Time Initials Expect calls from State Health and/or C.D.
c.
Officials concerning plant conditions.
8.
Notify the Security Shif t Supervisor to activate the telephone paging system for plant personnel and Yankee NSD personnel.
9.
When contacted by the Emergency Operations Facility Coordinator, advise him of the classification and emergency conditions.
10.
Direct the activities of the emergency response personnel until overall responsibility is assumed by the Technical Support Center Coordinator.
- 11. Request assistance of outside agencies (fire, law enforcement, or medical rescue personnel and related equipment) as needed to deal with the Site Area Emergency.
Fire Medical Law Enforcement (in conjunction with the Security Shift Supervisor)
Subsequent Actions:
1.
Changing conditions may require escalation of emergency classification to a more severe condition.
Assess conditions periodically and be prepared to initiate this condition in concert with the T.S.C.
Coordinator, pR, 2.
In concert with the T.S.C. Coordinator, provide information to assist with the final closecut of the Site Area E=ergency condition.
Final Conditions:
1.
When the Site Area Emergency conditions no longer exist, announce on the plant page system that the Site Area E=ergency is ended.
2.
Summarize all actions and resultant conditions in the Shif t Supervisor's Log.
Page 3 of 3 w
\\>
f vuned tes.t.3 MEMORANDUM
./
To Plant Procedure Manual Holders Vernon y,
f/f((
ROM AthnL erno FILE 6.1.5 4
5U2 JECT Chance o Plant Procedure Manual e, u 9 //
DE?ARTMENT INSTRUCTION
[2.~Y Concurring Individual: W Daee: 7_ /9/&Z _
SRO Concurring:
b h
L Date:.~L/9 8'1 u
2[9 r E.
Second SRO Concurring:
[
kucf,.
Date:
pv Chenistry and Health Physics Supervisor or Plant Health Physicist:
Date:
This instruction becomes effective on the date that a Second Senior Licensed Operator signs above, unless a Health Physics procedure is involved, in which case this instruction becomes ef fective on the date that a Senior Licensed Operator and the Chemistry and Health Physics Supervisor or the Plant Health Physicist signs above.
Instruction Cancelled:
Rev.
//;
of Of d M 3 1
Scope of Instruction:
n
%b 1 Hb -l--
.,x.
Reasen for Change:
antw I
4 B
Reviewed M 4 /""78 Approved
[,
[/.JP/Y\\
FORCgecrerdry
?'lantManagerg A.P. 0832, Figure 1
~Rev. 7 K
e p
0.P. 3503
[
DI #82-4 I.
APPENDIX 1 GENERAL - SHIFT SUPERVISOR / PLANT DIERGENCY DIRECTOR Time Initials Immediate Actions:
1.
Conditions have been assessed and the applicable Emergency Operating Procedures are utilized.
If a release is in progress, refer to 0.P. 3513,
" Evaluation of Radiological Conditions."
2.
The type of emergency (General) has been determined from A.P. 3125, Classification of Emergencies.
3.
Determine the knmediate personnel response to be taken.
4.
Turn the Page System Volume Increase Switch to the " Evacuation" position, turn the Alarm Switch to the "0N" position for fifteen seconds, and then announce the following over the Plant Paging System:
" General Emergency, General Emergency, General a.
Emergency" b.
"There is (what) in/at (where)."
c.
" Emergency response personnel report to the Technical Support Center, the Operations Support Center, and the Emergency Operations Facility as required. All other personnel, visitors, and contractors report to the Governor Hunt House Information Center" 5.
Notify the Shif t Technical Advisor to report to the Control Room and provide assistance.
6.
Notify the NRC on the NRC Emergency Notifica-tion System red phone. Maintain an open, continuous communications channel on this line.
Notify the New Hampshire, Massachusett=, and Vermont 7.
a.
State Police Agencies by depressing number 111 on the Nuclear Alert System orange phone (or utilizing telephone backup) and making the following announcement upon establishing communications:
"This is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have a General Emergency.
We recommend that the general public be advised to seek shelter.
Page 1 of 3
~__-
0.P. 3503 APPENDIX I (Continued)
DI #82-4 Time Initials I repeat, this is Vermont Yankee Nuclear Power Station in Vernon, Vermont. We have a General Emergency, please acknowledge with your name, your state and a repetition of the message."
Vermont Name of Dispatcher N.H.
Name of Dispatcher Mass.
Name of Dispatcher b.
As soon as the initial message (Step 7a.) has been-acknowledged by all the Vermont, New Hampshire and Massachusetts State Police, hang up.
Make a subsequent notification to the Verment State Police by depressing 213 on the Nuclear Alert phone and provide the following statements:
1.
"This is Vermont Yankee Nuclear Power Station";
~
2.
"We have declared (indicate the emergency' class) because (indicate the initiating condition per 0.P. 3125)";
3.
"The plant is (pick one) a.
continuing normal operation, b.
reducing present power levels, or c.
shutdown";
4.
"A release (pick one) a.
is anticipated, b.
is in progress, or c.
is not expected to occur as a result of present accident conditions.";
5.
"Present meteorological conditions indicate (provide wind speed and direction)";
6.
"At the present time we recommend (pick one) a.
no protective action, or b.
that the general public be advised to seek shelter until further notified."
(Use b.
for General Emergency Classes.)
l 7.
"I repeat, this is Vermont Yankee Nuclear Power Station.
Please acknowledge with your name."
Vermont Name of Dispatcher Pace 2 of 1
s 0.P. 3503 APPENDIA I (Continusd)
DI #82-4 Time Initials Expect calls from State Health and/or C.D.
c.
Officials concerning plant conditions.
8.
Notify the Security Shift Supervisor to activate the telephone paging system for plant personnel and Yankee NSD personnel.
9.
When contacted by the EOF Coordinator, advise him of the classification and emergency conditions.
10.
Direct the activities of the emergency response personnel until overall responsibility is assumed by the Technical Support Center Coordinator.
11.
Request assistance of outside agencies (fire, law enforcement, or medical rescue personnel and related equipment) as needed to deal with the General Emergency.
Fire 4
Medical Law Enforcement (in conjunction with the Security Shift Supervisor)
Subsequent Actions:
1.
In concert with the T.S.C. Coordinator, provide information to assist with the final closeout of the General Emergency condition.
Final Conditions:
1.
When the General Emergency conditions no longer exist, announce on the plant page system that the General Emergency is ended.
2.
Summarize all actions and resultant conditions in the Shif t Supervisor's Log.
O-I Page 3 of 3 l
.... -