Forwards Safety Evaluation of SEP Topics XV-8, Evaluation of Control Rod Misoperation Events, XV-11, Inadvertent Loading & Operation of Fuel Assembly in Improper Position, & XV-13, Spectrum of Rod Drop Accidents
ML20041C673
Person / Time
Site: La Crosse File:Dairyland Power Cooperative icon.png
Issue date: 02/26/1982
From: Linder F
DAIRYLAND POWER COOPERATIVE
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
TASK-15-08, TASK-15-11, TASK-15-13, TASK-15-8, TASK-RR LAC-8117, NUDOCS 8203020448
Download: ML20041C673 (10)


Text

DlDA/RYLAND h

[k COOPERAT/VE

(608) 788 4000 Februa ry 26, 1982 In reply, please refer to LAC-8117 DOCKET NO. 50-409 U. S. Nuclear Regulatory Commission f

ATTN:

Mr. Darrell G. Eisenhut, Director Division of Licensin Of fice of Nuclear Reactor Regulation 0

1 Division of Operating Reactors Washington, D. C.

20555

{g

SUBJECT:

DAIRYLAND POWER COOPERATIVE (DPC)

LA CROSSE BOILING WATER REACTOR (LAC 8WR)

N PROVISIONAL OPERATING LICENSE NO. DPR-45 SEP TOPIC XV-8, EVALUATION OF CONTROL ROD MISOPERATI SEP TOPIC XV-11, INADVERTANT LOADING AND OPERATION OF A ASSEMBLY IN AN IMPROPER POSITION SEP TOPIC XV-13, SPECTRUM 0F ROD OROP ACCIDENTS

REFERENCE:

(1) DPC Letter, LAC-7387, Linder to Eisenhut, dated February 27, 1981.

Gentlemen:

Our letter, Reference 1, identified topics for DPC to submit for NRC evaluation.

The subject topics were listed in the schedule submitted with Reference 1.

Enclosed find the Safety Evaluation Reports (SER) for Topic XV-8, Evaluation of Control Rod Misoperation Events, Topic XV-11, Inadvertant Loading and Operation of a Fuel Assembly in an Improper Position and Topic XV-13, Spectrum of Rod Drop Accidents.

If there are any questions regarding this submittal, please contact us.

Very truly yours, DAIRYLAND POWER COOPERATIVE Ab g

Frank Linder, General Manager FL:SJR:eme cc:

J. P. Keppler, Regional Director, NRC-DRO III NRC Resident Inspector WP1 g

I, Qt t

8203020448 820226 l

PDR ADOCK 05000409 P

@@R

LA CROSSE BOILING WATER REACTOR SYSTEMATIC EVALUATION PROGRAM SAFETY EVALHATitJ'_ REPORT TOPIC XV-8 EVALUATION OF CONTROL R00 MISOPERATION EVENTS In boiling water reactors the control rods are moved one at a time (as opposed to gang movement in pressurized water reactors).

The control rod withdrawal sequence to be used during startup and operation of the LACBWR is specified and enforced by procedures. The rod movements are performed in such a way as to keep the power distribution within the requirements of the limiting conditions for operation and to achieve the desired power shape. A control rod misoperation event occurs when a control rod is moved out of sequence or is moved beyond its prescribed limits.

There are 29 cruciform-shaped bottom entry control rods in the LACBWR core.

The control rods are manipulated by 29 identical control rod drive mechanisms that operate independently of each other.

The LACBWR is unique among BWR's in that control rod movement is accomplished by rotation of a leadscrew, which moves a roller nut assembly along the length of the leadscrew.

The motion of the roller nut acts through a push rod to position the control rod in the core. All control rod withdrawals and slow insertions are accomplished by a constant speed electric motor driving the leadscrew so that the control rod moves vertically at a speed of 20 inches per minute.

Individual control rod movements as small as a few hundredths of an inch may be made with this system. High speed control rod insertions (typically less than 2.2 seconds for full 84" insertion) are accomplished by driving the leadscrew with a hydraulic motor.

Each control rod position is continuously indicated through signals generated by two independent control rod position indicating systems.

The primary indicating mechanism is a synchro-torque transmitter that transmits its angular position, corresponding to the travel position of the lower section of the rod drive, to a synchro-torque receiver at the control panel. The secondary indicating mechanism indicates the travel position of the roller nut assembly by an ALNICO magnet that moves with the roller nut assembly, all parts of the upper section of the rod drive.

In addition, there is a full in and a full withdrawn position light in the Control Room for each control rod.

These lights are actuated by two limit switches on the lower section of the rod drive.

WP1 -

R00 MIS 0PERATION DURING STARTUP During reactor startup and power escalation LACBWR control rods are withdrawn in banks. Each control rod is individually withdrawn in small increnents to form specified banks. The increnental withdrawal amounts are quite small, typically less than one inch when the reactor is critical or near critical and usually less than 1/4 of an inch. Continuous full in to full out rod withdrawal is never perfonned.

Reactor criticality is achieved with all 29 control rods banked at approximately the same level.

Since this provides a very high control rod density and very low neutron flux in the core below the bank height, the worth of any control rod that might be inadvertently withdrawn is limited to a small value, typically less than one percent reactivity.

As the systen is heated up and/or power is escalated, a 20 rod bank made up of the outer rods and a checker board pattern of the inner rods is withdrawn while 5 of the inner rods renain inserted 92% and 4 additional rods renain inserted 83%.

After the 20 Group C rods are fully withdrawn, the 9 renaining rods are brought to a bank condition at 83% insertion, and then pairs of diametrically opposed rods are withdrawn with the pairs following each other at 25 inch intervals. This control rod withdrawal sequence assures that the core power density renains conservatively low at all times and that the worth of any inserted control rod (even in the unlikely event of a rod selection error) is limited to less than the Technical Specification limit of 2.5% Ak/k.

The probability of a control rod being fully withdrawn out of sequence due to operator error is extrenely smali since several hundred rod selections must be made over an extended period of time to acconplish the full withdrawal of any given rod.

In the very low probability event of a hot short in the control rod drive system causing a continuous withdrawal of a rod, the rate of reactivity insertion is limited by the slow, constant drive speed of 20 inches per minute or approximately 4.15 minutes for full travel. Analyses reported in the LACBWR Safeguards Report (ACNP-65544, Revised, August 1967) indicate that even for an extrenely conservative reactivity insertion rate of 1.2 x 10-3 Ak/k/sec in a cold-clean (just critical) core, the maximum fuel tenperature would be only about 1514*F and no fuel damage would occur.

R0D MISOPERATION AT POWER A rod misoperation event at power occurs if an operator makes a mistake and -

withdraws the wrong rod or withdraws a proper rod too great a distance or if a very low probability failure of a control rod drive system should occur causing a continuous withdrawal of a rod. The probability of a significant operator error is extranely small since a given rod is normally moved only a small fraction of an inch at a time. The controlling rods are typically moved less than 1/3 of an inch per day.

i Nevertheless, the consequences of complete withdrawal of the highest worth rod 4

from the controlling rod pattern are calculated for each fuel cycle. For this calculation the core is assumed to be operating at full power at the beginning of the cycle and to be free of xenon. The calculation is performed with a reactor simulator code and since the LACBWR control rods move very slowly it is assumed that the neutron flux and-heat flux are in equilibrium.

The results of this analysis for fuel cycle 6 was reported in LAC-TR-067 (DPC Letter, LAC-6130, Linder to Zieman, dated February 26,1979).

This analysis typically shows that the complete withdrawal of a control rod at power causes the reactor power to increase to approximately 110% of rated power but the minimum critical power ratio in the fuel remains above the allowed XN-2 correlation minimum of 1.32.

CONCLUSION Based on the above evaluation, we conclude that the analysis of the control rod misoperation meets the acceptance criteria of Standard Review Plan Sections 15.4.1,15.4.2 and 15.4.3 at the Dairyland Power Cooperative La Crosse Boiling Water Reactor.

i 4

LA C'<0SSE BOILING WATER REACTOR SYSTEMATIC EVALUATION PROGRAM SAFETY EVALUATION REPORT TOPIC XV-11 INADVERTANT LOADING AND OPERATION OF A FUEL ASSEMBLY IN AN IMPROPER POSITION EVALUATION A number of fuel misloading events have been evaluated in conjunction with recent LACBWR refueling licensing requirements. Two types of misloading have been evaluated. The improper rotational error, in the proper core location, is of negligible impact because of the enrichment and georaetric symmetry of the fuel assemblies and the symmetry of the control rods around each fuel assembly. Loading of a fuel assembly in an improper core location is addressed by procedural controls during refueling and by a core verification subsequent to refueling.

In the event such a mislocation does occur and is not detected by the visual core verification, the impacts on thermal-hydraulic performance have been analyzed.

The effects on CPR, LHGR, and cold shutdown margin of a fuel assembly loaded in an improper location are such that the core parameters will remain within the respective specified safety limits throughout the fuel cycle. Since incore power instrumentation is not used at LACBWR, it is assumed that all misloading errors are undetected i

during reactor operations.

1 CONCLUSION Based on these evaluations, the acceptance criteria of SEP XV-ll and SRP-15.4.7 for the Inadvertant Loading and Operation of Fuel Assembly in an Improper Position are met at the Dairyland Power Cooperative La Crosse Boiling Water Reactor.

WP1 t

REFERENCES (1) Letter to Frank Linder (DPC) from Dennis L. Ziemann (ORB),

dated May 25, 1979.

(2) Letter LAC-974 to Dennis L. Ziemann (ORB) from Frank Linder (DPC), dated May 9, 1979.

(3) Letter LAC-6130 to Dennis L. Ziemann (ORB) from Frank Linder (DPC), dated February 26, 1979.

WF1 t

LA CROSSE BOILING WATER REACTOR SYSTEMATIC EVALUATION PROGRAM SAFETY EVALUATION REPORT TOPIC XV-13 j

SPECTRUM 0F R00 DROP ACCIDENTS EVALUATION:

The rod drop accident was recently evaluated for the La Crosse Boiling l

Water Reactor (LACBWR) by Nuclear Energy Services, Inc. The results of the analysis are contained in the report, "LACBWR Rod Drop Probability Study,"

Document NES-81A0033, Rev. 1, previously submitted to the NRC.* A comparison of methods used in this analysis with the SRP 15.4.9 acceptance criteria follows.

P i

Criterion 1 - Reactivity excursions should not result in radially averaged i

fuel rod enthalpy greater than 280 cal /gm at any axial location in any fuel rod.

1 i

As noted in the NRC staff evaluation of the LACBWR Rod Drop Probability i

l Report,** the maximum probability of occurrence of a rod ' drop accident resulting in a peak fuel enthalpy of greater than 280 calorie's/ gram is less than 10-7 per reactor year.

The reactor conditions necessary to produce such an occ6rrence include a power level greater than 45% of rated, a rod drop distance greater than 35 inches, and a rod reactivity worth of greater th?n 1.4% ak/k.

  • Attachment 2 of Letter LAC-6905 from Frank Linder (DPC) to Dennis L.

Ziemann (Nk:<), dated May 8, 1980.

    • Letter from Dennis M. Crutchfield (0RR) to Frank Linder, i

dated December 5, 1980.

WP1,

,,,,y,-y,,

--,,,,1-,

m,.w,

, -_ ~,

w-,w-

,.-,.,,.,,u

--,-e

.~ --,,.,,,,

,,-m,-

,w,.-,

,4

.,r---

.- +- -,.

Criterion 2 - The maximum reactor pressure during any portion of the assumed excursion should be less than the value that will cause stresses to exceed the

" Service Limit C" as defined in the ASME Code.

The probability of occurrence for the rod drop accident, based on conservative assumption, is sufficiently below the 10-7 per reactor year-level to preclude the necessity of a specific analysis. However,' other analyses addressing pressure transients show that the primary coolant pressure boundary is protected by safety devices such as relief valves.

In addition, the rod drop accident impacts a relatively localized area of the core, and thereby reducing the overall pressure transient in the reactor.

Criterion 3 - The number of fuel rods predicted to reach assumed fuel failure thresholds and associated parameters such as the amount of fuel reaching melting conditions will be an input to a radiological evaluation.

The assumed failure thresholds are a radially averaged fuel rod enthalpy greater than 170 cal /gm at any axial location for zero or low power initial conditions, and fuel cladding dry out for rated power initial conditions.

The probability for a radiological release resulting fran a rod drop accident which produces a fuel rod enthalpy greater than 170 cal / gram is analyzed in a manner similar to the rod dorp accident occurrence.

The rod drop probability factors, as listed in Table 1 of the "LACBWR Rod Drop Probability Study" are disconnection, sticking, non-detection, high rod worth, rod drop timing,' and total rod withdrawals.

Of these probability factors, only the probability that sufficient rod worth exists and the fraction of the year during which the event can occur (rod drop timing) are different for the 170 cal /gm analysis than those used for the 280 cal /gm analysis.

Conservatively assuming that the probability of each of these two factors goes WP1 to 1.0 x 100 to achieve a deposited enthalpy of 170 cal /gm, and assuming no credit for the difference in strength between typical Zircaloy clad fuel and the stainless steel clad LACBWR fuel assemblies, the probability of occurrence for a radiological release is calculated as shown in Table 1.

The resultant maximum probability for occurrence is less than the acceptance criterion of 10-7 events per reactor year.

CONCLUSION Based on a complete review, it is concluded that the probability of a rod drop accident is sufficiently below the NRC acceptance criterion of 10-7 to conform to the requirements of SEP XV-13 and SRP 15.4.9.

WP1 r

TABLE 1 LACBWR RADIOLOGICAL RELEASE PROBABILITIES ASSOCIATED WITH A R00 DROP ACCIDENT EXPEC TED MAXIMUM EVENT PROBABILITY PROBABILITY

- Rod Disconnection 4.0 x 10-5 1.2 x 10-4

- Rod Sticking 1

x 10-3 1

x 10-2 Non-Detection 1

x 10-8 1.5 x 10-5 High Rod Worth 1

x 100 1

x 100 Rod Drop Timing 1

x 100 1

x 100-Total Rod' Withdrawals 4.5 x 102 4.5 x 10 -

2 Probabilty/ Year of 1.8 x 10-13 8.1 x 10-9 Rod Drop Resulting in 170 cal / gram e

i

- WP1 _

_ - -