ML20041C321

From kanterella
Jump to navigation Jump to search
Suppl 1 to Proposed Change 176 to Amend License DPR-3 Modifying Tech Specs to Allow for Change in Number of Operable Incore Neutron Detector Thimbles for Remainder of Cycle 15 Power Operation
ML20041C321
Person / Time
Site: Yankee Rowe
Issue date: 02/25/1982
From: Vandenburgh D
YANKEE ATOMIC ELECTRIC CO.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20041C322 List:
References
FYR-82-21, PC-176-1, NUDOCS 8203010162
Download: ML20041C321 (2)


Text

.

. YANKEE ATOMIC ELECTRIC COMPANY

/7p f

1671 Worcester Road, framingham. Massachusetts 01701 PC-176-1

  • Yauxes rya 82-21 N-e -

Proposed Change No. 176 Supplement No. 1 Februa ry 25, 1982

' 'S s

United States Nuclear Regulatory Commission

//

pggg; FED Washington, D. C.

20555 q

f ag?. 619825-6 FER Attention:

Of fice of Nuclear Reactor Regulation s

,. y Lact r.pr a y

Re f e rence s :

(a)

License No. DPR-3 (Docket No. 50-29)

~

/ 982 (b) YAEC Letter to USNRC (FYR 82-16), dated February 1

" Proposed Change No. 176"

    1. /

Subject:

Supplement No. 1 to Proposed Change No. 176

Dear Sir:

Enclosed is Supplement No. 1 to Reference (b) which contains information re ga rdi ng the requested change to the Technical Specifications.

PROPOSED CilANGE Reference (b) requested a change to the Yankee Plant Operating License No. DPR-3.

The change involved the Incore Instrumentation System.

The following changes supercede the changes originally requested.

1.

Modif y Specification 3.3.3.2 to allow for a change in the number of ope ra ble incore neut ron detector thimbles for the remainder of Cycle 15 powe r opera tion.

2.

Modify Specifications 4.2.1.2, 4.2.2.1, 4.2.2.2, and 4.2.3.2 to allow for the calculational dif ferences which must be implemented when different numbers of incore neutron detector thimbles are o pe ra b le.

RE ASON FOR CilANCE The reasons supporting the requested change are the same as those given in the original proposal. The only dif ferences in this supplement a re 1) the manner in which the operability of the Inc o re Instrumentation System is documented in the Technical Specifications, and 2) the manner in which certain core parameters a re calculated for the different operating modes of the Incore Instrumentation System.

SAFETY CONSIDERATIONS This change, as supplemented by this letter, involves the gathering of data suppo rting react or core opera tions. Operation within the proposed Technical Specification will not endanger the health and safety of the public.

This supplement has been reviewed by the Nuclear Safety Audit and Review Comm i t t e e.

g0 F203010162 820225 PDR ADOCK 05000029

$s f

p PDR

United States Nuclear Regulatory Comnisnion Fe brua ry 25, 1982 Attention: Of fice of Nuclear Reactor Regulation Page 2 FEC DETERMINATION This supplement to the Proposed Change provides additiomil information requested by the NRC and is a part of the change described in Reference (b),

which was determined to be a Class III amendment, and for which a payment of

$4,000 has been submitted.

SCHEDULE OF CHANGE As discussed with your staff, Yankee is requesting an expedited review of this Proposed Change.

ADDITIONAL INFORMATION During discussions with your staf f regarding the original proposed c ha nge, a request was made for inf o rmation about how incore measurements a re made and how the various core parameters are calculated. What follows is a description of some of the calculational methods for the existing Specification as well as the proposed Specificaton.

Ulth 12 or more neutron detector thimbles operable, the core power distribution is determined on a full core basis using distance weighting f rom the inst rumented thimbles. The Yankee core has rotational quarter core symmet ry and the option exists to rotate all thimbles into one quadrant.

Both the full core and quadrant rotation options will be used to monitor power dist ribution if two of the following thimbles: F-2, G-6, F-7, o r H-7, become I nope ra ble.

The most conservative value of the peak full power LHCR determined by the two methods will be used to determine the allowable thermal power.

We t rust that you will find this submittal satisfactory.

Howe ve r, should you desire additional information, please contact us.

Ve ry t ru ly you rs,

YANKEE ATOMIC ELECTRIC COMPANY D. E.

Va nden bu rg h Senior Vice President COM!!ONUEALTli 0F !!ASSACHUSETTS)

)ss MIDDLESEX COUNTY

)

Then personally appeared before me, D. E. Va ndenburgh, who, being duly sworn, did state that he is a Senior Vice President of Yankee Atomic Electric Compa ny, t ha t he is duly authorized to execute and file the foregoing request in the name and on the behalf of Yankee Atomic Electric Company and that the statements therein are true to the best of hi s knowledge and belief.

R6bert H. Groce Notary Public My Commission Expires Septenber 14, 1984