ML20041C204

From kanterella
Jump to navigation Jump to search
Notifies That QA Program Must Be Approved Prior to Registration as User of Delivery of Licensed Matl to Carrier Transport,Per 10CFR71,in Response to .Acceptance Criteria Encl
ML20041C204
Person / Time
Site: 07109033, 07109035
Issue date: 02/09/1982
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Richardson C
ABC TESTING
References
NUDOCS 8202260332
Download: ML20041C204 (14)


Text

.

7/-4633 21

'103Y FEB 09 1982 h b.[o.

a nwc w 3 C (,- %

i FCTC:ZDM 71-9033 71-9035 9

9.

q ABC Testing

[

E3C3IVEU ATTH: 11r. Carleton A. Richardson 2,

FEB101982> 1 86 Walnut Street n a me n*.7 Bridgewater,f1A 02324

':m w d3 9X

/

Gentlemen:

9.3

/

This is in response to your letter dated December 23, 1981 concern 169 package registration.

Section 71.12 of 10 CFR Part 71 requires as a condition of general license provisions an approved quality assurance (QA) program. Accordingly, we are unable to register you for use of the package (s) mquested at this time. It will be necessary for you to obtain an approved QA program prior to the registration as a package user or the delivery of licensed material to a carrier for transport pursuant to 10 CFR Part 71.

To assist you in preparing your QA program description, enclosed are the acceptance criteria the staff uses to evaluate a licensee's QA program and a QA program that the staff has found acceptable for meeting the applicable requirements for special fom radioactive material.

Sincerely, Original Signed by CHARLES E. MACDONALD Charles E. MacDonald, Chief l

Transportation Certification Branch l

Division of Fuel Cycle and Material Safety, NMSS L

Enclosures:

As stated Distribution: % cwf.-

ZDMcDonald LLGordon Docket File NRC PDR IE HQ (3)

NMSS R/F FCTC R/F

="c >.... d.C)$p......!C1j 5*^"tqc,h,} d. a,1,q,@,ac,,na).y, 8202260332 820209 PDR ADOCK 07109033

.0 J.TB2...... 02/. /.02...

c paa o:,n p Nic F%M 318 (10-80) NFICM 0240 OFFICIAL RECORD COPY

s ;., g =

March 27,1980 (R2 Vision 2) 10 CFR PART 71 OA PROGRAM

~

~

i FOR INDUSTRIAL RADIOGRAPHY LICENSEES

... ~.

1.

Organizhtion The final responsibility for the Quality Assurance (QA) Program for Part 71 Requirements rests with (Company Name). Design and Fabrication shall not be conducted under this QA Program.

The QA Program is imple-mented using the follcwing organization:

Note: The Organizational Chart as used in the license application should be presented.

It may be advisable to designate the Radiation Safety Officer as the responsible individual for the Part 71 QA Requirements.

The Radiation Safety Officer is responsible for overall administration of the program, training,and certi'ftcation, document control, and auditing.

4 The Radiographers are responsible for handling, storing, shipping, inspection, test and operating status and recordkeeping.

l 2.

Quality Assurance Program The management of (Company Program) establishes and implements this QA Program. Training, prior to engagement, for all QA functions is required according to written procedures.

QA Program revisions will be made according to written procedures with management approval. The QA Program will ensure that all defined QC procedures, engineering procedures, and specific provisions of the package desip approval are satisfied. The QA program will emphasize control of the characteristics of the package '

which are critical to safety.

The Radiation Safety Officer shall assure that all radioactive material shipping packages are designed and mandfectured under a QA Program approved -

by the Nuclear Regulatory Comission for all packa;es designed or fabri-cated after January 1,1979. This requirement will be satisfied by receiving a certification to this effect from the manufacturer.

3.

Docment Control All documents related to a specific shipping package will be controlled through the use of written procedures. All document changes will be performed according to written procedures approved by management.

The Radiation, Safety Officer shall insure that all QA functions are conducted in accordance with the latest applicable changes to these documents.

9

m

/[

I r

4.

Handling, Storage, and Shipping Written safety procedures concerning the handling, storage, and shipping of packages for certain special form radioactive material will be followed.

Shipments will not be made unless all tests, certifications, acceptances, and final inspections have been completed. Work. instructions will be provided for handling, storage, and shipping operations.

Radiography personnel shall perform the critical handling, storage, and shipping operations.

5.

Inspection, Test, and Operating Status Inspection, test, and operating status of packages for certain special l

form radioactive material will be indicated and controlled by written procedures. Status will be indicated by tag, label, marking, or log entry. Status of nonconforming parts or packages will be positively maintained by written procedures.

Radiograrihy personnel shall perform the regulatory required inspections and tests in accordance with written procedures. The Radiation Safety Officer shall ensure that these functions are parformed.

6.

Quality Assurance Records Records of package approvals (including references and drawings),

1 i

procurement, inspections, tests, operating logs, at.dit results, personnel training and qualifications and records of shipments will be maintained'.

Descriptions of equipment and written procedures will also be maintained.

These records will be maintained in accordance with written procedures.

The records will be identified and retrievable. At list of these records, with their storage locations, will be maintained by the Radiation Safety Officer.

7.

Audits Established schedules of audits of the QA Program will be perfonned using written check lists.

Results of audits will be maintained and reported to management. Audit reports will be evaluated and deficient areas corrected. The audi.ts will be dependent on the safety significance of the activity being audited, but each activity will be audited at least once per year. Audit reports will be maintained as part of the quality assurance records. Members of the audit team shall have no responsibility in the activity being auditedt t

e

\\

t 10 CFR 71 - APPEtiDIX E ACCEPTAt1CE CRITERIA - TRAf4SPORTATI0fi PACKAGES FOR fl0RMAL/SPECIAL FORM RADI0 ACTIVE MATERIAL I.

Organization 1.

Provide a statement that the responsibility for the QA program is retained and exercised by the applicant.

2.

Identify and describe the QA/QC functions performed by the applicant's QA organization or dele' gated to other organizations providing controls to assure appropriate elements of Appendix E will be implemented.

3.

Provide a current organizational chart that identifies the organizational elements which function under the control of the QA program.

4.

Identify and describe the responsibilities of each job function shown on the organization chart.

5.

Describe the duties and qualifications of the individual who retains overall authority and responsibility for the QA program.

6.

Provide a statement that designated QA individuals have the responsibility and authority, delineated in writing, to stop unsatisfactory work and control further p'rocessing, delivery, or installation of nonconforming material.

II. Quality Assurance Program 1.

Provide a statement that management (i.e., above or outside the QA organization) regularly assesses the scope, status, implementation, f_

and effectiveness of the QA program to assure that the program is adequate and complies with 10 CFR Part 71, Appendix E criteria.

2.

Provide a statement that provisions are established to control the distribution of the QA manuals and revisions thereto.

~

e S

,'r 3.

Provide a statement that provisions are established for communicating to all responsible organizations and individuals that quality policies, QA manuals, and procedures are mandatory requirements which must be implemented and enforced.

4.

Identify the safety-related systems, structures and components controlled by the QA program.

5.

Provide a statement that provisions are established for the resolution of disputes involving quality, arising from a difference of opinion between QA/QC personnel and other department (engineering, procurement, manufacturing, etc.) personnel.

6.

Provide a statement that an indoctrination and training program is established such that:

(1) Personnel responsible for performing quality-related activities are instructed as to the purpose, scope, and implementation of the QA manuals, instructions, and procedures.

(2) Personnel performing quality-affecting activities are trained and qualified in the principles and techniques of the activity being performed.

(3) The scope, the objective, and the method of implementing the indoctrination and training program are documented.

(4) Proficiency of personnel performing quality-affecting activities is maintained by retraining, reexamining, and/or recerti fying.

7.

Provide a statement that quality-related activities are performed with specified equipment under suitable environmental conditions, and prerequisites have been satisfied prior to inspection and test.

III. Design Control 1.

Provide a statement that measures are established to carry out design activities in a planned, controlled, and orderly manner.

2.

Provide a statement that measures are established to correctly translate the applicable regulatory requirements and design bases into specifica-tions, drawings, written procedures, and instructions.

3.

Provide a statement that quality standards are specified in the design documents, and deviations and changes from these quality standards are controlled.

4.

Provide a statement that designs are reviewed to assure tha'. (1) design characteristics can be controlled, inspected and tested and (2) inspection and test criteria are identified.

5.

Provide a statement that praper selection and accomplishment of design verification or checking processes such as by design reviews, alternate calculations, or qualification testing are performed.

When a test program is used to verify the adequacy of a design, a qualification test of a prototype unit under design conditions should be used.

6.

Provide a statement that individuals or groups responsible for design verification are other than the original designer and the designer's imediate supervisor.

7.

Provide a statement that design and specification changes are subject to the same design controls and approvals that were applicable to the original design unless the licensee designates another qualified responsible organization.

8.

Provide a statement that the positions or groups responsible for design reviews and other design verification activities and their authority and responsibility are identified and controlled by written procedures.

IV. Procurement Document Control 1.

Provide a statement that procedures are established that clearly delineate the sequence of actions to be accomplished in the prepara-tion, review, approval, and control of procurement documents.

2.

Provide a statement that procurement documents identify the applicable 10 CFR Part 71, Appendix E requirements which must be complied with and described in the supplier's QA program.

3.

Provide a statement that procurement documents contain or reference the design basis technical requirements including the applicable regulatory requirements, material and component identification requirements, drawirigs, specificatione, codes and industrial standards, test and inspection requirements, and special process instructions.

4.

Provide a statement that procurement documents identify the documen-tation (e.g., drawings, specifications, procedures, inspection and fabrication plans, inspection and test records, personnel and procedures qualifications, and chemical and physical test results of material) to be prepared, maintained, and submitted to the purchaser for review and approval.

5.

Provide a statement that procurement documents identify those records to be retained, controlled, and maintained by the supplier, and those delivered to the purchaser prior to use or installation of the hardware.

6.

Provide a statement that procurement documents contain the procuring agency's right of access to supplier's facilities and records for source inspection and audit.

'7.

Provide a statement that changes and revisions to procurement documents are subject to at least the same review and approval as the original document.

V.

Instructions, Procedures, and Drawings 1.

Provide a statement that activities affecting quality are prescribed and accomplished in accordance with documented instructions, procedures, or drawings.

2.

Provide a statement that provisions are established which clearly

~

~

delineate the sequence of actions to be accomplished in the prepara-tion, review, approval, and control of instructions, procedures, and drawings.

3.

Provide a statement that the QA organization reviews and concurs with inspection plans; test, calibration, and special process procedures; drawings and specifications; and changes thereto or acceptable alternatives are described.

VI.

Document Control 1.

Provide a statement that the review, approval, and issue of documents and changes thereto, prior to release, are procedurally controlled to assure they are adequate and the quality requirements are steted.

2.

Provide a statement that changes to documents are reviewed and approved by the same organizations that performed the original review and approval or by other qualified responsible organizations delegated by the applicant.

3.

Provide a statement that approved changes are included in instructions,,

procedures drawings, and other documents prior to implementation of the change.

p 4.

Provide a statement that documents are available at the location where the activity will be performed prior to commencing the work.

w, e e =~

.s.

5.

Provide a statement that a master list, or equivalent, is established to identify the current revision number of instructions, procedures, specifications, drawings, and procurement documents.

VII. Control of Purchased Materials, Parts and Components 1.

Provide a statement that qualified personnel evaluate the supplier's capability to provide acceptable quality services and products.

2.

Provide a statement that the evaluation of suppliers is based on one or more of the following:

(1) The supplier's capability to comply with the elements of Appendix E to 10 CFR Part 71 that are applicable to the type of material, equipment, or service being procured.

(2) A review of previous records and performance of suppliers who have provided similar articles of the type being orocured.

(3) A survey of the supplier's facilities and QA program to determine his capability to supply a product which meets the design, manufacturing, and quality requirements.

3.

Provide a statement that the results of supplier evaluations are documented and filed.

4.

Provide a statement that surveillance, if required, of suppliers durim fabrication, inspection, testing, and shipment of materials, equipment and components is planned and performed in accordance with written precedures to assure conformance to the purchase order requirements.

5.

Provide a statement that the supplier furnishes the following records as a minimum to the purchaser:

(1) Documentation that identifies the purchased material or equipment and the specific procurement requirements (e.g., codes, standards, and specifications) met by the items.

(2) Documentation that identifies any procurement requirements which have not been met together with a description of those nonconformances dispositioned " accept as is" or " repair."

6.

Provide a statement that receiving inspection of the supplier-furnished material, equipment, and services is performed to assure:

4

- (1) The material, component, or equipment is properly identified and corresponds with the identification on receiving documentation.

(2) Material, components, equipments, and acceptance records are inspected and judged acceptable in accordance with predetermined inspection instructions, prior to installation or use.

(3)

Inspection records or certificates of conformance attesting to the acceptance of material and components are available prior to installation or use.

(4)

Items accepted and released are identified as to their inspection status prior to forwarding them to a controlled storage area or releasing them for further work.

VIII.

Identification and Control of Materials, Parts, and Components 1.

Provide a statement that procedures are established to identify and control materials, parts, and components including partially fabricated subassemblies.

2.

Provide a statement that the identification and control procedures assure that identification is maintained either on the item or on records traceable to the item to preclude use of incorrect or defective items.

3.

Provide a statement that identification of materials and parts important to the function of safety-related systems and components can be traced to the appropriate documentation such as drawings, specifications, purchase orders, manufacturing and inspection documents, deviation reports, and physical and chemical mill test reports.

4.

Provide a statement that the location and the method of identification do not affect the fit, function, or quality of the item being identified.

5.

Provide a statement that correct identification of materials, parts, and components is verified and documented prior to release for fabrication, assembling and installation.

IX. Control of Special Processes 1.

Provide a statement that special processes such as welding, heat treating, nondestructive testing, and cleaning are procedurally controlled.

x-2.

Provide a statement that procedures, equipment, and personnel connected with special processes are qualified in accordance with applicable codes, standards, and specifications.

3.

Provide a statement that qualification records of procedures, equipment, and personnel associated with special processes are established, filed, and kept current.

X.

Inspection c

1.

Provide a statement that an inspection program which verifies conformance of quality-affecting activities with requirements is established, documented, and accomplished in accordance with written and controlled procedures.

2.

Provide a statement that inspection personnel are independent from the individuals performing the activity being inspected.

3.

Provide a statement that inspectors are qualified in accordance with applicable codes, standards, and company training programs; and their qualifications and certifications are kept current.

4.

Provide a statement that modifications, repairs, and replacements are inspected in accordance with the original design and inspection requirements or acceptable alternatives.

5.

Provide a statement that provisions are established that identify nandatory inspection hold points for witness by an inspector.

XI. Test Control 1.

Provide a statement that a test program to demonstrate that the item or component will perform satisfactorily in service is established, documented, and accomplished in accordance with written controlled procedures.

2.

Provide a statement that modifications, repairs, and replacements are tested in accordance with the original design and testing requirements or acceptable alternatives.

3.

Provide a statement that test results are documented, evaluated, and their acceptability determined by a qualified, responsible individual or group.

XII. Control of Measuring and Test Equipment 1.

Provide a statement t5st measuring and test instruments are calibrated at specified intervals based on the required accuracy, purpose, degree of usage, stability characteristics, and other conditions affecting the measurement.

2.

Provide a statement that measuring and test equipment is identified and traceable to the calibration test data.

3.

Provide a statement that measures are taken and documented to determine the validity of previous inspections performed when measuring and test equipment is found to be out of calibration.

4.

Provide a statenent that refereace and transfer standards are traceable to nationally recognized standards; or, where national standards do not exist, provisions are established to document the basis for calibration.

XIII. Handling, Storage, and Shipping 1.

Provide a statement that special handling, preservation, storage, cleaning, packaging, and shipping requirements are established and accomolished by qualified individuals in accordance with

~-

predetermined work and inspection instructions.

2.

Provide a statement that all conditions (operations, tests, inspections, specifications, etc.) of the NRC package approval and the U.S.

Department of Transportation shipping requirements are satisfied prior to shipment.

3.

Provide a statement that all necessary shipping papers will be prepared, as required.

4.

Provide a statement that departure, arrival time and destination of a package will be established and monitored to a degree consistent with the safe transportation of the package.

XIV.

Inspection, Test and Operating Status 1.

Provide a statement that identification of the inspection, test, and operating status of packages and components is known by affected organizations.

2.

Provide a statement that the application and removal of inspection and welding stamps and status indicators such as tags, markings, labels, and stamps are procedurally controlled.

3.

Provide a statement that bypassing of required inspections, tests, and other critical operations is procedurally, controlled.

4.

Provide a statement that the status of nonconforming, inoperative, or malfunctioning packages or components it identified to prevent inadvertent use.

XV. Nonconforming Material, Parts, or Components 1.

Provide a statement that the identification, documentation, segregation, review disposition, and notification to affected organizations of nonconforming materials, parts, components, or services are procedurally controlled.

2.

Provide a statement that documentation identifies the nonconforming 4

item; describes the nonconformance, the disposition of the nonconformance, and the inspection requirements; and includes signature approval of the disposition.

3.

Provide a statement that nonconforming items are segregated from acceptable items and identified as discrepant until properly dispositioned.

=

4.

Provide a statement that acceptability of rework or repair of materials, parts, components and systems is verified by reinspecting and retesting the item as originally inspected and tested or by a method which is at least equal to the original inspection and testing method.

XVI. Corrective Action l.

Provide a statement that evaluation of conditions adverse to quality (such as nonconformances, failures, malfunctions, deficiencies, deviations, and defective material and equipment) is conducted to determine the need for corrective action in accordance with established procedures.

2.

Provide a statement that corrective action is initiated following the determination of a condition adverse to quality to preclude recurrence.

3.

Provide a statement that follow-up reviews are conducted to verify

=

proper implementation of corrective actions and to close out the corrective action documentation.

XVII. Quality Assurance Records 1.

Provide a statement that sufficient records are maintained to provide documentary evidence of the quality and safety of items and the activities

_ ;n _

affecting quality and safety.

2.

Provide a statement that QA records include operating logs; results of reviews, inspections, tests, audits, and material analyses; qualification of personnel, procedures, and equipment; and other documentation such as drawings, specifications, procurement documents, calibration procedures and reports; nonconformance reports; and corrective action reports.

3.

Provide a statement that records are identifiable and retrievable.

4.

Provide a statement that a list of the required records and their storage locations will be maintained.

5.

Provide a statement that design related records (e.g., drawings, calculations etc.) are maintained for the life of the shipping package and all other records are maintained for a minimum of two years.

6.

Provide a statement that inspection and test records contain the following where applicable:

(1) A description of the type of observation.

(2) Evidence of completing and verifying a manufacturing, inspection, or test operation.

(3) The date and results of the inspection or test.

(4)

Information related to conditions adverse to qualit",

(5)

Inspector or data recorder identification.

(6) Evidence as to the acceptability of the results.

XVIII. Audits 1.

Provide a statement that audits are performed in accordance with preestablished written procedures or check lists and conducted by personnel not having direct responsibilities in the areas being audited.

2.

Provide a statement that audit results are documented and then reviewed with management having responsibility in the area audited.

3.

Provide a statement that responsible management takes the necessary action to correct the deficiencies revealed by the audit.

4.

Provide a statement that deficient areas are reaudited on a timely l

basis to verify implementation of corrective actions which minimize recurrence of deficiencies.

5.

Provide a statement that audits of the QA program are performed at least annually based on safety significance of the activity being audited.

l 1

l s

a hm

_ _ _ _ _ _ _ _ _ _ _.. _ _ _