MORGAN, LEWIG E BOCKlUS PHILAccLPHiA COUN S ELORS AT law ETED LoS Awortes New YoRM 18 o 0 M STR ECT, N.W.
M8AM8 H A% RIS B U R G WAS HIN GTON, D.C. 2 0 o3 6 paris
'02 R.9 y n.g Taw. o a: taoas on-sooo Gromoc L. EDGAR bE o.o o...., woa. n...='
rebruary 24, 1982 The Honorable Nunzio J. Palladino The Honorable Peter Bradford Chairman Commissioner U. S. Nuclear Regulatory Commission U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Washington, D. C.
20555 The Honorable Victor Gilinsky The Honorable John F. Ahearne Commissioner Commissioner U. S. Nuclear Regulatory Commission U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Washington, D. C.
20555 The Honorable Thomas F. Roberts Commissioner U. S. Nuclear Regulatory Commission Washington, D. C.
20555 Re:
Clinch River Breeder Reactor Plant Docket No. 50-537 (Section 50.12 Request)
Gentlemen:
I have enclosed for filing with the Commission three charts which are Exhibits 3, 4, and 5 to the February 23, 1982 Arthur Andersen & Co. submission (see-page 2, footnote 1), and which were inadvertently omitted from that filing.
Resp ully submitted, George L. Edg Attorney for Project Management Corporation s
cc:
Distribution List a
q)
S RECEiwin 2:
FE3 2 51982:n 10; M
EEEMjfpu s
o e:
jf g
t_k g
8202260200 820224 PDR ADOCK 05000537 C
l r
s
)
1 EXHIBIT 3 MANAGEMENT COST DISCOUNT ANALYSIS e
l No Delay 82 83 84 85 86 87 88 89 90 Man Years 101 132 118 106 100 83 68 35 Rate 110.5 119.3 128.9 139.2 150.3 162.4 175.3 189.4 204.5 (thousands)
Cost 11.2 15.7 15.2 14.8 15.0 13.4 11.9 6.6 (millions)
Discounted 11.2 14.1 12.4 10.9 9.8 7.9 6.4 3.2
= $75.9 Delay.
Man' Years 101 101 132 118 106 100 83 68 35 Cost-11.2 12.
17.
16.4 15.9 16.2 14.5 12.9 7.2 (millions)
Discounted 11.2 10.8 13.8 12.1 10.5 9.6 7.8-6.2-3.1 = $85.1 Difference
= $ 9.2 Assumptions:
Inflation rate of 8%
Discount rate of 11%
~
~
v s.
EXHIBIT 4 MANAGEMENT COST DISCOUNT ANALYSIS e
RM's No Delay 82 83 84 85 86 87 88 89 90 Man Years 100 111 108 101 100 67 34 4
Rate 101.6 109.7 118.5 128.
138.2 149.3 161.2 174.1 188.
Cost 10.2 12.2 12.8 12.9 13.8 10.
5.5 9.7 Discounted 10.2 11.
10.4
'9.5 9.1 5.9 2.9
.34
= $59.34 Delay Man Years 100
-100 111 108 101 100 67 34 4
Cost 10.2 11 13.2 13.8 14 14.9 10.8 5.9
.75 i
(millions)
Discounted 10.2 9.9 10.7 10.1 9.2 8.8.
5.8 2.8
.32 = $67.82 Difference
= $8.48 M 4
Assumptions:
Inflation rate of 8%
Discount rate of 11%
e o.
EXHIBIT 5 MANAGEMENT COST DISCOUNT ANALYSIS o
B&R No Delay 82 83 84 85 86 87 88 89 90 Man. Years 102 132 119 104 82 77 62 44 Rate 60.2 54.0 70.2 75.8 81.9 88.5 95.5 103.2 111.4 (thousands)
Cost 6.1 8.6 8.4 7.9 6.7 6.8 5.9 4.5 (millions)
Discounted 6.1 7.7 6.8 5.8 4.4 4.0 3.2 2.2
= $39.4 Delay Man Years 102 102 132 119 104 82 77 62 44 Cost 6.1 6.6 9.3 9.0 8.5 7.3 7.4 6.4 4.9 Discounted 6.1 5.9 7.6 6.6 5.6 4.3 4.0 3.1 2.1 = $45.3 Difference
= $ 5.9 M Assumptions:
Inflation rate of 8%
Discount rate of 11%
=
0 DISTRIBUTION LIST
- The Honorable Nunzio J. Palladino Chairman U. S. Nuclear Regulatory Commission Washington, D. C. 20555
- The Honorable Peter Bradford Commissioner U. S. Nuclear Regulatory Commission Washington, D. C.
20555
- The Honorable Victor Gilinsky Commissioner U. S. Nuclear Regulatory Commission Washington, D. C.
20555
- The Honorable John F. Ahearne Commissioner U. S. Nuclear Regulatory Commission Washington, D. C.
20555
- The Honorable Thomas F. Roberts Commissioner U. S. Nuclear Regulatory Commission Washington, D. C.
20555
- Marshall E. Miller, Esquire Chairman Atomic Safety & Licensing Board U. S. Nuclear. Regulatory Commission Washington, D. C.
'20545 Dr. Cadet H. Hand, Jr.
Director Bodega Marine Laboratory University of California P. O. Box 247 Bodega Bay, California 94923
- Mr. Gustave A. Linenberger Atomic Safety & Licensing Board U. S. Nuclear Regulatory Commission Washington, D. C.
-20545
- Daniel Swanson, Esquire Office of Executive Legal Director U. S. Nuclear Regulatory Commission Washington, D. C.
20545
' y
- Stuart Treby, Esquire Office of Executive Legal Director U. S. Nuclear Regulatory Commission Washington, D. C.
20545
- Atomic Safety & Licensing Appeal Board U. S. Nuclear Regulatory Commission f
Washington, D. C.
20545 j
- Atomic Safety & Licensing Board Panel-U. S. Nuclear Regulatory Commission i
Washington, D. C.
20545
- Docketing & Service Section Office of the Secretary U. S. Nuclear Regulatory Commission Washington, D. C.
20545
- (3 copies)
William B. Hubbard, Esquire Assistant Attorney General State of Tennessee Office of the Attorney General 422 Supreme Court Building Nashville, Tennessee 37219 Dak Ridge Public Library Civic Center Oak Ridge, Tennessee 37820 Herbert S. Sanger, Jr. Esquire General Counsel Tennessee Valley Authority 400 Commerce Avenue Knoxville, Tennessee 37902 Lewis E. Wallace, Esquire W. Walter LaRoche, Esquire James F. Burger, Esquire Edward J. Vigluicci, Esquire l
Office of the General Counsel Tennessee Valley Authority 400 Commerce Avenue
~
Knoxville, Tennessee 37902
- Dr. Thomas Cochran i
Natural Resources Defense Council 1725 Eye Street, N. W.,
Suite 600 Washington, D. C.
20006
- Barbara A. Finamore, Esquire Natural Resources Defense Council, Inc.
1725 Eye Street, N.W., Suite 600 Washington, D. C.
20006
_ g L
Mr. Joe H. Walker 401 Roane Street Harriman, Tennessee.37748 Ellyn R. Weiss Harmon & Weiss 1725 Eye Street, N.W., Suite 506 Washington, D. C. 20006 Lawson McGhee Public Library 500 West Church Street Knoxville, Tennessee 37902 William E. Lantrip, Esquire-Attorney for the City of Oak Ridge 253 Main Street, East P. O. Box 1 Oak Ridge, Tennessee 37830
- Eldon V. C. Greenberg, Esq.
Tuttle & Taylor 1901 L Street, N.W., Suite 805 Washington, D. C. 20036 Commissioner James Cotham Tennessee Department of Economic and Community Development Andrew Jackson Building, Suite 1007 Nashville, Tennessee 37219 Leon Silverstrom, Esq.
Warren E. Bergholz, Jr.
U. S. Department of Energy Room 6-B-256 -- Forrescal Building 1000 Independence Avenue, S.W.
Washington, D. C. 20585 f
- /
Denotes hand delivery
.