j INSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT
- s. LACE NSE E a.EIucI'eer p.ca!atory Commission A OFF CE Dr. Rafael Fossas Office of Inspec! ion er.d Enforcement Office 305, First Federal Buildin9 Region il Suite 3!00 Stop 23 Ponce De Leon 101 M:rieth Street M'l Santurce, Puerto Rico 00909 A!!anta Gccrm. ?0103
- s. DoCMET *euwsEnts)
- 4. LsCEN SE Muu ss ngS)
- e. D A TE OF INSPECTION
/
l 7
.m 52-19025-01
<h
- s. INSPECTION FINDtNGS glj The inspection was an examination rf the actnities conducted under your licerise as they relate to radiation safet p &nce will)the Commnsion's rules and regulations and the condihons of your hcense. T he inspection condsted of wiective exami at. $r procedures and repre.
sentatne records, interviews with personnel, and observations by the inspector. T he findings as a result of this ins gM are as follows:
'Q No items of noncompliance or unsafe conditions were found.
/
/
The following items of noncomphance related to records, signs, and labels were found:
j YA A. Rooms or areas were not properly posted to indicate the presence of a RADIATION AREA.10CFR 20.203(b)or34.42
\\.
B. Rooms or areas were not properly posted to indicate the presence of a illGli RADI ATION AREA.
10 CFR 20.203(c)(1) or 34.42
'N '
O C. Rooms or areas were not properly posted to indicate the presence of an AIRBORNE RADIOACTIVITY AIki A.
O D. Rooms or areas were not properly posted to indicate the presence of RADIOACTIVE MATERIAL.10 CFR 20.203(c) i E. Containers were not properly labeled to indicate the presence of RADIOACTIVE MATERIAL 10 CFR 20.203(f)(1) or (f)(2) l F. A current copy of 10 CFR 20,a copy of the license, or a copy of the operating procedures was not properly posted or l
made available.10 CFR 20.206(b)
O G. Form NRC-3 was not properly posted.10 CFR 20.206(c) i O 11. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)
O I. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b) or 34.43(d)
J. Records of receipt, transfer, disposal, export or inventory oflicensed material were not properly maintained.
10 CFR 30.51,40.61 or 70.51 K. Records ofleak tests were not maintained as prescribed in your license, or 10 CFR 34.25(c)
O L Records ofinventoties were not maintained.10 CFR 34.26 O
M. Utilization logs were not maintained.10 CFR 34.27 N. Records of radiation survey instrument calibration were not maintained.10 CFR 34.24 O
O. Records of teletherapy electricalinterlock tests were not maintained as prescribed in your license.
P. Other
-~
/
l l
.i
- s
(\\RC Inmec,or, 7 The NRC Inspector has explained and I understand the items of noncompliance listed above. The items of noncompliance will be corrected within the next 30 days.
8202220274 820113 NMS LIC30
((O1,%
S2-19025-01 PDR n.,
n,n, u,,,,,,n,.... n.,,,., n.i,-,
ORIGINAL 10 LICENSEE
.