.'r-OPERATING DATA REPORT a

DOCKET NO.

50-263_____.

DATE 2-d-82___

C0tiPLETED bY A.

L.

Myrab.

TELEPHONE 612/295-515-OPERATING STA.TUS l Notes 1.

Unit Name

_____________________.___Monticelto l

2.

Reporting period: _ _____

_ ___ ___ JANUARY I

3.

Licensed Theru.aL Power (MWt)

_________ _1670 l

4.

Nameplate Rating (Grors MWe)-

______..______569 l

5.

Design Electrical Rating (Net MWe)- ___ _545.4 1

6.

Maximum Dependable Capacity (Gross MWe)

__553 l

7.

Maximum Dependable Capacity (Net MWe)

_ __ _5 2 5 -

l__________________________

G.

If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons: __ Maximum Dependable Capacity Reduced 11 MWe due_.

__to removal of 1.ith stage low pressure t urb ine b lades (items 6 & 7)___.

9.

Power Level To Which Restricted, If Any (Net hWe)'

___N/A________________..__

10. Reasons For Restrictions, If Any:

__N/A____________________________________.

This Month Yr.-to-Date Cumulativt

11. Hours In Reporting Period

_____744

_____ 744

____ 9283:

12. Number Of Hours Reactor Was Cr i t ica L

___394.3

___ 394.3

__ 75329.'

13. Reactor Reserve Shutdown Hours

_____0.0

______0.0

_____940.

i

14. Hours Generatar On-Line

___343.7

___ 343.7

__ 73553.-

15. Unit Reserve Shutdown Hours

_____0.0

______0.0

_______0.t

16. Gross Thermal Energy Generated (MWH)

_ 526661 526661

_12020900;

17. Gross Electr ica L Energy Generated (MWH)

_176642

__ 176642

__38182014

10. Net Elec tr ica L Energy Generated (MWH)

__168030

__ 168030

__3651155:

19. Unit Service Factor

__ 46.2%

___ 46.2%

__ __ 79. 2:

20. Unit Availability Factor

__ 46.2%

___ 46.2%

____ 79. 2:

21. Unit Capacity Factor (Using HDC Net)

__ 43.0%

___ 43.0%

____ 74.9:

22. Unit Capacity Factor (Using DER Net)

__ 42.3%

___ 42.3%

____ 73. 6:

23. Unit Forced Outage Rate 4.8%

4.8%

6.i:

24. Shutdowns Scheduled Over Next 12 Months (Type, Date, and Duration of Each)

__ September 4, 1982 - Refueling Outage - 45 days _____._____..___________

25. If Shut Down At End Of Report Period, Estimated Date Of Startup:___N/A_____
26. Units In Test Status (Prior to Commercial Operation)- N/A Forecast Achieve INITIAL CRITICALITY INITIAL ELECTRICITY COMMERCIriL GPERATION 8202190299 820215 PDR ADOCK 05000263 R

PDR

('

AVERAGE. DAILY. UNIT POWER LEVEL DOCKCT NO.

50-263____ _

UNIT HonticelLo _

DATL 2-3-82 ___

CUMPLETED BY A. L. Myrabo TELEPHONE 612/295-5151

-MONTH ____ _-JANUARY DAY AVERAGE DAILY POWER LEVEL

, DAY AVERAGE DAILY POWER LEVEL (MWe-Net)-

(MWe-Net) i

-4____________

17 15____________

9

-3__._

18

____227_

3

-4____________

19

__________495____________

4.

-4____________

20

__.________523____________

5

~4 __.___.______

21

_ _ _ _5 2 8_ _ _ _._ _ _ _ _ _.

6

-4___.____._

22

_ _ _ _._ _ _ _5 2 ~7 _ _ _ _ _ _ _._

7

__.________-4___.____._

23

_53'_

a 8

_ _ _. _ -4 ____ ___._ _

24

_ _494._ _______

9

_.__.__--4__._____._

25

___.__5ii__

I.

10

___.__.___._-3____.__.___.

26-

___513 __.______.__

4 l

l i1

-4____

9_7

__-__528______.__-___

i 5

12

-4____

28

__.___545

'13

____.____.__.-4_____._

29

_____540___

14

-5_____.__._

30

__._._._.538_

'15

'.i_______.._.

31

_ __534_

16

-5____________

[

INSTRUCTIONS On this format, List the average daity unit power level in MWe-Net for each i day in the reporting month.

Compute to the nearest whole megawatt.

i l

4 4

-.. mea.

ww.e.

.~..e.---

,* j NARRATIVE

SUMMARY

OF OPERATING EXPERIENCE DOCI'ET NO.

50-263______

DATE 2-3-82____

COMPLETED DY A. L. Myrabc TELEPHONE 612/295-5151 MONTH ______ JANUARY 1-1-82 to Continuation of 1981 FALL Inaintenance outage.

.1-15 1-16-82 Reactor critical.

Generator on-Line for warm-up run.

1-17-82 Generator off-line for turbine overspeed test.

1-i7-82 Generator on-Line. -Generator off-Line for inspection of turbine bearing.

1-18-82 to Generator.on-Line.

Power ope,ation.

1-31-82 l

l l

Note: Power operation defined as essentially 100% of rated power except for weekend load drops for specified surveillance testing.

s O '~

y.

V UNITSilUTDOWNS \\ND POWER T EDUCTIONS DOCKET NO.50-263-UNIT N AME ' iDnticello.

DATE -M*

REPORT \\1ONT!! January COMPLETED BY _ A. Myrabo -

TELEPHONE - 612/295-5151 E

=

es u, -

c 3

1 y

7 - f La.cernee 5*

g 9.,

Cause & Correctne L

Dat e 25

.3.

~

Esent 27 c.?

- Atijon to 3E

s jfg Report =

n'

,5 ~~

. Present Recurrence -

v

_2_

16('81) 1-1-32 S

381.7 B

1 N/A ZZZZ ZZZZZZ Continuation of 1981 Itall.'laintenance outage 1

1-17-82 S

1.2 B

1-N/A IIA

'IURBIN Generator off-line for turbine over-speed test 2

1-17-82 F

17.4 II 1

N/A IIA

'IURBIN Generator off-line 'for inspection of -

  1. 9 bearing

{

I 3

'4 F: Forced Reason; Method:

Eslubit G -Instructions S. Schedufed A.Ega:pment Failure (Explaint

! Manual for Preparation of Data Balaintenance of Test 12 Manual Scram.

Entr> Sheets for Licensee C. Refueling 3 Autom.itie Scram.

Esent Report (LER) File (Nt' REG-D Reculatory Restriction 4-Other ( Explain i :

.0161)

E-Operator Training & License Esamination.

F-Adr:-inistrative

.5 G-Operational Er ror ( E xplaia l Eshibit 1 Same Source (9/77)

Il-O:her i Esplain) a, ',

d

.g 4

%