ML20040H348

From kanterella
Jump to navigation Jump to search
Notifies That IE Info Notice 81-37,Revision 1, Unnecessary Radiation Exposures to Public & Workers During Events Involving Thickness & Level Measuring Devices, Was Sent to Listed Licensees on 820209
ML20040H348
Person / Time
Issue date: 02/09/1982
From:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
NUDOCS 8202180133
Download: ML20040H348 (13)


Text

",

[pcem b

UNITE] STATES o

[

  • h NUCLEAR REGULATIRY COMMISSION

[

,E REGION V 1450 MARIA LANE, SUITE 260 o,

4 U

WALNUT CREEK, CAUFORNIA 94596 o

February 9, 1982 z>>

~f i

/

s..

3 L

_/

2,,

~ " A f,1ggy

\\ t:.

U,,

,7 ~+g

\\'

g

\\,.

MEMORANDUM T0: ALL THOSE ON INFORMATION NOTICE DISTRIBUTION LIST.

._ dj;3

/

FROM:

REGION V

SUBJECT:

INFORMATION NOTICE NO. 81-37, Rev. 1: UNNECESSARY RADIATION EXPOSURES TO THE PUBLIC AND WORKERS DURING EVENTS INVOLVING THICKNESS AND LEVEL MEASURING DEVICES The attached Information Notice No. 81-37, Rev. I was issued this date to the attached list of licensees.

8202180133 820209 NMS LIC30

[q[

PDR

</

4ER05 PACE CORPORAVIDH ATR FORCE DEPAP,TMENT OF THE AIR FORCE, DEPARTMENT OF THE iRC LIC. #:-

04-07326-03 HRC LIC. #:

02-13870-01 NRC LIC. #2 04-06705-01 350 E EL SEGUNDO BLVD 390 STRATEGIC MISSLE WING (SAC USAF CHEMICAL AHD MATERIALS BRANCH

,L SEGUNDO CA 90245 DAVIS-MONTHAN AFB AZ 85707 LKL BUILDING 8451

~

EDWARDS AFB CA 93523 jIR FORCE, DEPARTMENT OF Thi AIR FORCE, DEPARTMENT OF THE AIR FORCE, DEPARTMENT OF THE RC LIC. 3:

04-03699-01 NRC LIC. #2 04-11398-03 NRC LIC. #:

04-11469-01 ACRAMENTO AIR LOGISTICS CTR.- DIRE ICBM TEST MAINTENANCE SQUARDROH/MBR 9TH STRATEGIC RECONNAISSANCE WING HDUSTRIAL LABORATORY DIVISION

CCLELLAN AFB CA 95652 VANDENBERG AFB CA 93437 BEALE AFB CA 95903 jIR FORCE, DEPARTMENT OF THE AIR FORCE, DEPARTMENT OF THE AIR FORCE, DEPARTMENT OF THE 1RC LIC. #

04-13885-01

'HRC LIC. #

04-09951-03 NRC LIC. #:

04-09951-05

$EROSPACE FUELS LABORATORY (SA00LE) 1155Til TECHNICAL OPERATIONS SQ. MCC USAF CLINIC MCCLELLAN/SGB 6ATERIAL AREA (AFLC)

IANDENBERCAFB CA 93437 MCCLELLAN AFB CA 95652 MCCLELLAN AFB CA 95652 jLASKA LUMBER & PULP COMPANY LTD.

ALASKA, STATE OF ALASKA, STATE OF tRC LIC. #:

50-11218-02 NRC LIC. #:

50-09056-01 NRC LIC. #:

50-14858-01 ILE 6 SAWMILL CREEK ROAD, P0 ALASKA DIVISION OF EMERGENCY SERVIC DEPT OF ENVIRONMENTAL CONSERVATION, ITKA AK 99335 P.O. BOX 2267 750 ST. ANN'S AVENUE PALMER AK 99645 DOUGLAS AK 99824 E'HCHORAGE SAND & GRAVEL CO. INC.

ANUENUE FISHERIES RESEARCH CENTER ARCTIC PIPE INSPECTION INC.

RC LIC. #:

50-19697-01 HRC LIC. #:

55-18197-01 HRC LIC. #:

50-17314-01 813 EAST FIRST AVENUE SAND ISLAND, AREA 4 P. O.

BOX 1296 HCHORAGE AK 99501 HONOLULU HI 96819 KEHAI AK 99611 RMY, DEPARTMENT OF THE ARMY, DEPARTMENT OF THE ARMY, DEPARTNENT-OF THE RC LIC. #:

02-09090-01 HRC LIC. #:

04-04279-01 HRC LIC. #:

04-14061-01 ADIAC FACILITY -

US ARMY CALIBRATION AND REPAIR CENT CORPS OF ENGINEERS SOUTH PACIFIC DI 3UILDING 12508, WEST RANGE P.O. BOX 37

  1. T. HUACHUCA AZ 85613 SACRAMENTO CA 95315 SAUSALITO CA 94965 g

y,d n W 32 h v L

1RMY, - DEP ARTMENT' 0F THE ARMY, DEPARTMENT OF THE ASSOCIATED ASPHALT PAVING LTD.

RC LIC. #:

04-17365-01 HRC LIC. #:

36-15041-02 NRC LIC. #:

50-19473-01 I

kORP OF ENGINEERS-MATERIALS TESTIN USAE NORTH PACIFIC DIVISION MATERIA P.

O.

BOX 60288

\\

CA 96858.

RT. 2, BOX 12A

_FAIRBANKS

'AK 99706

)POSANFRANCISCO LDG. 230, FORT SHAFTER TROUTDALE OR 97060.

jTLANTYC RICHFIELD COMPANY BECHTEL PETROLEUM INC.

BELL, HERRING 8 ASSOCIATES.

RC LIC. #:

50-18441-01 HRC LIC. #:

04-16103-01 HRC LIC. #:

50-19638-01 S' ORTH-AMERICAN PRODUCING DIV., ALAS P.O. BOX 3965 3340 ARCTIC BLVD., SUITE 201

' f fHCHORAGE

.0.

BOX 360 SAN FRANCISCO CA 94119 ANCHORAGE'

'AK 99503' AK 99510 j

s l

' l I

kOARD OF WATER SUPPLY BOMHOFF AND ASSOCIATES INC.

BREWER CHEMICAL CORPORATION RC LIC. #:

53-14057-01 NRC LIC. #:

50-18034-01 HRC LIC. #:

53-16502-02 ITY AND COUNTY OF HONOLULU CONSTRUCTION INSPECTION 311 PACIFIC ST.

30 S. BERETAHIA STREET 1020 NEST IHTERNATIONAL AIRPOR h0HOLULU HI' 96817.

{

COHOLULU HI 96813 ANCHORAGE AK 99502

{

1 i

I b F BRAUN & COMPANY CHARLES POOL 1 ASSOCIATES, INC.

CHEVRON U. S.

A.

INC.

bRCLIC. #:

04-01186-03 HRC LIC. #:

50-19298-01 HRC LIC. #:

53-17787-01 3000 S.

FREMONT 1225 TONGASS AVENUE HAWAIIAN REFINERY-3LHAMBRA CA 91802 KETCHIKAH AK 99901 P. O. BOX 29789 HONOLULU HI 96820 1

!HRIS BERG INC. 8 INTERNATIONAL BRI CITY 1~ COUNTY OF' HONOLULU CITY AND COUNTY OF HONOLULU i

DRC LfC. #:

56-19285-01 NRC LIC. #:

53-16592-01 HRC LIC. #:

53-16592-02 BOARD OF WATER SUPPLY.

DEPARTMENT OF PUBLIC WORKS

{0INTVENTURE

.0.

BOX 2117 9 630 5. BERET ANI A/P.O.. BOX 3410 650 SOUTH KING STREET 8AKH POSTAL FAC.

GU 96921 H0HOLULU HI 96843 HONOLULU HI 96813 l

30MMERCE, DEPARTMENT OF COMMERCE, DEPARTMENT OF COMMERCE, DEPARTMENT OF NRC LIC. #:

46-06377-04 HRC LIC. #:

50-16908-01 QRC LIC. #:

46-06377-01 NATIONAL OCEANIC AND ATMOSPHERIC AD NATIONAL MARINE FISHERIES SERVICE A QATIDHAL MARINE FISHERIES SERVICE A

-2725 MONTLAKE BOULEVARD, EAST

)EATTLE WA 98102 SEATTLE WA 98112 AUKE BAY AK 99821 4

4

20MMERCE, DEPARTMENT OF CYPRUS HAWAIIAN CEMENT CORPORATION DAMES & MOORE-IRC LIC. #:. 04-13893-02 HRC LIC. #:

53-18471-01 NRC LIC. 3: ~53-19129-01 0AA,'NMFS, SWFC TIBURON LABORATOR 91-005 KADMI LOOP 1144 TOTH AVENUE 150 PARADISE DRIVE EWA BEACH HI 96706 HONOLULU-HI 96816 IBUROH "CA 94920

^EFENSE, DEPARTMENT OF DENALI ENGINEERING CD.

EHERGY RESOURCES COMPANY INC.

j IRC LIC, #:

04-14184-02 HRC LIC. #2 50-19751-01 HRC LIC. #

04-19352-01 l

EFENSE LOGISTICS AGENCY DEFENSE DE DRAWER B 3344 H.

TORREY PINES' COURT l

)HRISMANROAD COPPER CENTER AK 99573 LA JOLLA CA 92037 I

fRACY CA 95376 i

1 l

(NERGY, DEPARTMENT OF ENERGY, DEPARTMENT OF ENVIRONMENTAL PROTECTIDH AGENCY-9RC LIC. #3 46-12178-01 HRC LIC. #:

36-19375-01 HRC LIC. #:

46-10025-01

$0HNEVILLE' POWER ADMINISTRATIDH BONNEVILLE POWER ADMINISTRATION FIELD STUDIES SECTIDH

.0. BOX 491 P. O. BOX 3621 P.O. BOX 219 ANCOUVER WA 98660 PORTLAND OR 97208 WENATCHEE WA 98301 l

l

!HVIRONMENTAL PROTECTIDH AGENCY ENVIRONMENTAL PROTECTION AGENCY FELEC SERVICES INC.

3RC LIC. #3 27-05861-02 HRC LIC. #:

46-10100-02 HRC LIC. #2 05-16709-01 FNVIRONMENTAL MONITORING AND SUPPOR REGION.X LABORATORY 125 N. BARHES AVENUE f.0. BOX 15027 7411 BEACH DRIVE EAST COLORADO SPRINGS CO 80930 LAS VEGAS HV 89109 PORT ORCHARD WA 98366 kORD AEROSPACE AND COMMUNICATIONS C FRANK MOOLIN & ASSOCIATES INC.

GAMMA CORPORATION ORC LIC. #:

04-17873-01 HRC LIC. 8 50-19892-01 NRC LIC. #:

53-16847-01 939 FABIAN WAY POUCH B P.O.

BOX 430 gALOALTD CA 94303 BARROW AK 99723 WAHIAWA HI 96786 BEO-ENGINEERING & TESTING GUAM, UNIVERSITY OF HAWAII STATE DEPARTMENT OF LABOR AN QRC LIC. #3 56-18173-01 NRC LIC. #:

52-19618-01 HRC LIC. #2 53-17069-01 30ILS ENGINEERS AND MATERIALS TESTI AGRICULTURAL EXPERIMENT STATIDH COL DIVISI0H OF OCCUPATIONAL SAFETY AND J48 ASPINALL AVE., P.O.

BOX 35 UDG STATI0H 677 ALA MOAHA BLVD., SUITE 910 3GANA GU 96910 MANGILAD GU 96913 HONOLULU HI 96813 O,

.W

JAWAII,STATEOF HAWAZI, STATE OF HAWAIIAN ELECTRIC COMPANY INC.

RC LIC. #:

53-16076-01 NRC LIC. #

53-17656-01 NRC LIC. #:

53-08452-03 EPARTMENT OF HEALTH DEPARTMENT OF TRANSPORTATION, LAND P.O. BOX 2750

.0.

BOX 3378 2530 LIKELIKE HWY HONOLULU HI 07161 ONOHLULU HI 96801 HONOLULU HI 96819

'EALTH AND HUMAN SERVICES, DEPARTME HEALTH AND HUMAN SERVICES, DEPT. OF HEALTH EDUCATIDH AND WELFARE, DEPAR RC LYC.'#:

04-09759-01 HRC LIC. #:

02-19495-01 HRC LIC. #:

04-09763-01 UBLIC HEALTH SERVICE, FOOD AHD DRU INDIAN HEALTH SERVICE, PHOENIX AREA FOOD AND DRUG ADMINISTRATION LOS AN O UNITED HATIONS PLAZA, ROOM 801 E.

INDIAN SCHOOL ROAD 1521 W. PICO BOULEVARD AN FRANCISCO CA 94102 PHOEHIX AZ 85501 LOS ANGELES CA 90015 jEALTHEDUCATIONANDWELFARE,DEPAR HEALTH EDUCATION AND WELFARE, DEPAR HEALTH EDUCATION AND WELFARE, DEPAR RC LIC. #:

46-09750-01 HRC LIC. #:

02-16270-01 HRC LIC. #:

46-18301-01 00D AND DRUG ADMINISTRATION, FEDER HAVAJD AREA INDIAN HEALTH SERVICE D PUGET SOUND SERVICE UNIT 1

09 FIRST AVENUE P. 0. BOX G 1212-S0. JUDKINS EATTLE

. WA 98104 WINDOW ROCK AZ 86515 SEATTLE WA 98144 10HOLULU POLICE DEPARTMENT ICH PHARMACEUTICALS INC.

INTERIOR, DEPARTMENT OF THE C LIC. #:

53-12987-02' HRC LIC. #

04-15302-01 NRC LIC. #:

02-08779-01 455 5. BERETANIA STREET ICH CHEMICALS RADI0 ISOTOPES DIVISIO GEOLOGICAL SURVEY uGHOLULU HI 96814 2727 CAMPUS DRIVE 301 WEST CONCRESS ST.

IRVINE CA

92715, TUSCON

=AZ 85701

'HTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. #:

04-06674-02 NRC LIC. #:

46-03943-01 NRC LIC. 3:

50-11901-01 E0 LOGICAL SURVEY BUREAU OF T1INES SPOKAHE l1INING RESE GEOLOGICAL SURVEY, WATER RESOURCES-45 MIDDLEFIELD ROAD EAST 315 MONTGOMERY AVENUE 1209 ORCA STREET EHLO PARK CA 94025 SPOKANE WA 99207 ANCHORAGE AK 99501 HTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. #:

36-15021-01 NRC LIC.-#:

36-15059-01 NRC LIC. #:

36-15080-01

.S.

FISH AND WILDLIFE SERVICE BUREAU OF INDIAH AFF!. IRS BUREAU OF INDIAH AFFAIRS WARM SPRIN LOYD 500 BLDG., SUITE 1692 1425 N.

E.

IRVING STREET ORTLAND OR 97208 PORTLAND OR 97208-WARM SPRINGS OR 97761

.-_m

(HTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE IRC L2C. #:

46-15079-01 HRC LIC. 9:

04-15103-01 HRC LIC. #:

02-15106-01 UREAU OF INDIAH AFFAIRS BUREAU OF LAND MANAGEMENT CALIFORHI BUREAU OF INDIAN AFFAIRS PHOENIX AR OST OFFICE BOX 632 2800 COTTAGE WAY P.O. BOX 7007 OPPEHISH WA 98948 SACRA?1 ENTO CA 98525 PHOENIX AZ 85011 JHTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. #:

04-15259-01 HRC LIC. #

36-15528-01 NRC LIC. #:

36-15527-01 UREAU OF INDIAN AFFAIRS DUREAU OF LAND MANAGEMENT - EUGENE BUREAU OF LAND t1ANAGEMENT C005 BAY RANCH OF ROADS 2800 COTTAGEWA 1255 PEARL STREET 333 SOUTH 4TH STREET ACRAMENTO CA 95825 EUGENE OR 97401 C00S BAY OR 97420 NTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. #:

46-15846-01 NRC LIC. #:

46-15903-01 HRC LIC. #:

36-16357-01 UREAU OF INDIAN AFFAIRS, COLVILLE BUREAU OF INDIAH AFFAIRS SPOKANE AG BUREf'l 0F LAND MANAGEMENT, MEDFORD OST OFFICE BCX 111 P.

D.

BOX 6 310 W.

6TH STREET

.EAPELEM WA 99155 WELLPINIT WA 99040 MEDFG4D OR 97501 fMTERIOR, DEPARTt1EHT OF THE INTERICR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. #:

27-16664-01 HRC LIC. #:

04-16990-01 HRC LIC. #:

02-17208-01 UREAU OF RECLAMATION LOWER COLORAD BUREAU OF RECLAMATION MID-PACIFIC R BUREAU OF LAND MANAGEMENT, USDI

.0.

DOX 427 2800 COTTAGE WAY 2400 VALLEY BANK CENTER 0ULDER CITY HV 89005 SACRAMENTO CA 95825 PHOEHIX AZ 85073 3

fHTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LYC. #:

27-17597 NRC LIC. #:

46-17645-01 HRC LIC. #:

46-18085-01 E0 LOGICAL SURVEY, WRD YAKIMA PROJECT OFFICE GRAND COULEE PROJECT OFFICE MATERI 05 H. PLAZA STREET P.O.

BOX 1377 P.O.

BOX 620 ARSON CITY NV 89701 YAKIMA WA 989J1 GRAND COULEE WA 99133 J'HT ERI O R, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. #:

36-15526-02 NRC LIC. #:

36-18337-01 HRC LIC. #:

04-19249-01 UREAU OF L AND [1AHAGEMENT BUREAU OF LAND MANAGEMENT BUREAU OF RECLAMATION, AUBURN-FOLSO 550 LIBERTY RD.

S.

P.O.

BOX 3040 BIDDLE ROAD P.O.

60X 1309 ALEM CR 97302 MEDFORD OR 97501 AUBURH CA 95603

.___w

HTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE RC LIC. 3:

36-19313-01 NRC LIC. #:

02-19419-01 NRC LIC. 3 46-15078-02 UREAU OF LAND MANAGEMENT, BLM PRIN BUREAU OF INDIAN AFFAIRS BUREAU OF INDIAN AFFAIRS

.0.

BOX 550 ROUTE 1 BOX 9-C P.O.

BOX #120, STH & M STREET RINEVILLE OR 97754 PARKER AZ 85344 HOQUIAM WA 98550 fHTERIOR, DEPARTMENT OF THE INTERIOR, DEPARTMENT OF THE IRT CORPORATION

!RC LIC. 3 04-15259-02 NRC LIC. R:

36-19555-01 NRC LIC. 3:

04-18497-02 5UREAU OF INDIAN AFFAIRS CENTRAL CA BUREAU OF LAND MANAGEMENT P.O. BOX 30817

.0.

BOX 15740 777 N.W. GARDEN VALLEY BLVD.

SAN DIEGO CA 92138 ACRAMENTO CA 95813 ROSEBURG OR 97470 JUSTICE, DEPARTMENT OF KAISER CEMENT 1 GYPSUM COMPANY KEKAHA SUGAR COMPANY LIMITED yRC LIC. #:

04-13357-01 NRC LIC. 3:

04-03742-02 HRC LIC. 4 53-08148-02

  • RUG ENFORCEMENT ADMINISTRATION WES

$50 GOLDEN GATE AVENUE PERMANENTE CA 95014 KEKAHA HI 96752

)AN FRANCISCO CA 94102 10NA-HAWAIIAN MACADAMIA COMPANY LEONG, ARNOLD WF.

LOCKHEED AIRCRAFT CORPORATION I

9RC LIC. #:

53-17551-01 HRC LIC. 4:

53-19305-01 NRC LIC. 32 04-01964-07 kOST OFFICE BOX 16 DBA FIELD SERVICES LOCKHEED MISSILES & SPACE COMPANY lEALAKEKUA HI 96750 3744 AKEA RD.,

till LOCKHEED WAY KAUAI HI 96716 SUNNUVALE CA 94088 l

l 1

2AUI LAND AND PINEAPPLE COMPANY MCBRYDE SUCAR COMPANY LTD.

MUNICIPALITY OF ANCHORAGE I

ERC LIC. #:

53-17720-01 NRC LIC. #:

53-08969-01 NRC LIC. 8:

50-15852-01 l

P.

D.

BOX 187 LTD. MILL DEPARTMENT DEPARTMENT OF PUBLIC WORKS CONSTRUC

)

1AHULUI HI 96732 MILL DEPART!!ENT 3500 EAST TUDOR ROAD

(

ELEELE, KAUAI HI 96705 ANCHORAGE AK 99507 DAVY DEPT.

NAVY, DEPARTMENT OF THE NAVY, DEPARTMENT CF THE ORC LIC. A:

04-19816-01 NRC LIC. 3:

04-00364-02 NRC LIC. #:

04-01429-03 0AVAL SHIP WEAPON SYSTEMS ENGINEERI MARE ISLAND NAVAL SHIPYARD QUALITY U.S. MARINE CORPS 6SMSES, CODE 4510 MARINE CORPS LOGISTICS BASE PORY HUENEME CA 93043 VALLEJO CA 94592 BARSTOW CA 92311

i<AVY, DEPARTMENT OF THE HAVYo DEPARTMENT OF Tile NAVV, DEPARTMENT OF THE RC.LIC. #:

04-01757-07 NRC LIC. #:

04-04346-02 HRC LIC. 9:

04-07537-01 fAVALWEAPONSCENTER NAVAL TECHNICAL TRAINING CENTER HAVAL ELECTRONIC SYSTEMS ENGINEERIN

)HINA LAKE AFETY 8 SECURITY DEPT. CODE 2 TREASURE ISLAND 4297 PACIFIC HIGHWAY P. O. BOX CA 93555 SAN FRANCISCO CA 94130 SAN DIEGO CA 92138

)AVY, DEPARTMENT OF THE HAVY, DEPARTMENT OF THE NAVY, DEPARTMENT OF Tile (RC LIC. #:

53-06007-02 HRC LIC. #:

53-06007-03 NRC LIC. #:

46-09611-C2 EARL HARBOR HAVAL SHIPYARD, RADIAT PEARL HARBOR HAVAL SHIPYARD HAVAL UNDERSEA WARFARE ENGINEERING BOX 4C0 EARL HARBOR HI 96860 PEARL HARBOR llI 96860 KEYPORT WA 98345 1AVY, DEPARTMENT OF THE HAVY, DEPARTMENT OF THE HAVY, DEPARTMENT OF THE RC LIC. #:

46-09611-03 NRC LIC. #:

53-13243-02 HRC LIC. #

04-18225-01

.S.

HAVAL TORPEDO STATION PUBLIC WORKS CENTER, PEARL HARBOR BLDG. 118 C3DE 103 32ND 8 HARBOR DR. P.O. BOX 113 EYPORT WA 98345 PEARL HARBOR HI 96860 SAN DIEGO CA 92136 1AVY, DEPARTMENT OF THE NAVY, DEPARTMENT OF THE NAVY, DEPARTMENT OF THE ERC LIC. #:

04-09394-02 NRC LIC. #:

04-18347-01 HRC LIC. C:

04-01757-14 hAUALCONSTRUCTI0ttB4TTALIONCODE2 SHORE INTERMEDIATE MAINTENANCE ACTI HAVAL WEAPCHS CENTER, ORDNANCE SYST QAVAL CONSTRUCTION BATTALION C NAVAL STATION, BOX 106

' ORT HUENEME CA 93043 SAH DIEGO CA 92136 CHINA LAKE CA 93555 1AVY, DEPARTMENT OF THE NAVY, DEPARTf1ENT OF THE NAVY, DEPARTMENT OF THE

$RC LIC. #:

53-19400-01 NRC LIC. #

46-19259-02 NRC LIC. #:

46-03078-04 (AVALREG10HALMEDICALCLINIC, INDU TRIDENT REFIT FACILITY, SUBMARINE B PUGET SOUND HAVAL SHIPYARD LDG. 140, P.O.

BOX 121 IEARL HARBOR HI 96860 BANGOR BREMERTON WA 98315 BREMERTON WA 98314 AVY, DEPARTMENT OF THE HAVY, DEPARTMENT OF THE NERC0 INC.

02C LEC. #2 04-19811-01 HRC LIC. #:

04-19846-01 NRC LIC. #2 36-19095-01 AVAL AIR REWDRK FACILITY, HAS. ALA USS ACADIA (AD 42) 111 S.W. COLUMBIA SUITE 800 AVAL AIR STATION PORTLAND OR 97201 LAMEDA CA 94501 FPO SAN FRANCISCO CA 96647 M

OVATO CONSTRUCTION CO.

RUCLE0 HIC DATA SYSTEMS INC.

0AHU SUGAR COMPANY LTD.

RC LIC. #:

04-19527-01 HRC LIC. #:

04-19037-01 HRC LIC. #

53-11914-01 411 NAPA-VALLEJO HWY. P.O. BD 2811 MCGAW AVENUE P.O. BOX 0 APA CA 94558 IRVINE CA 92714 WAIPAHU HI 96797 AHU TRANSPORT CO LTD OREGON GRADUATE CENTER PACIFIC GAS AND ELECTRIC COMPANY RC LIC. #:

53-12546-01 NRC LIC. #3 35-19288-01 NRC LIC. #:

04-08134-03 90 SAHD ISLAND ACCESS RD STUDY AND RESEARCH 77 DEALE STREET

.0fl0 LULU HI 96819 19600 H.W. WALKER ROAD SAN FRANCISCO CA 94108 EEAVERTON OR 97005

[ACIFIC SOILS ENGINEERING 8 TESTING P1TTSBURGH AND MIDWAY COAL MINING C RAM CONSULTANTS INC.

JRC LIC. #2 54-19242-01 HRC LIC. #:

46-15449-01 NRC LIC. #:

50-19380-01 f. 0.

BOX 8453 100 EARKSDALE AVENUE P.O. BOX P. O. BOX 6087 (AMUNING GU 96911 DUPONT WA 98327 ANCHORAGE At 99503 l

l IOCKWELL INTERNATIONAL CORPORATION ROKE ELECTRICAL LOGGING INC.

SMITHKLINE CLINICAL LABORATORIES IN

!RC LIC. #:

04-17624-01 HRC LIC. #:

27-16976-01 NRC LIC. #:

53-18280-01

$ PACE DIVISION 604 LANDER STREET 2828 PAA STREET, #1140 22214 LAKEWOOD BOULEVARD REHO NV 89509 HONOLULU HI 96819

)0WNEY CA 90241 IOUTHERN CALIFORNIA EDISON COMPANY-TANAKA CONSTRUCTICH MANAGEMENT INC.

TED FORSI 1 ASSOCIATES INC.

RC LIC. 4:

04-17778-01 NRC LIC. #:

53-19056-01 HRC LIC. #:

50-19401-01 Ball DIEGO GAS ELECTRIC COMPANY 250-D WAIEHC BEACH ROAD 124 EAST SEVENTH AVENUE 2244 NALHUT GROVE AVE., P.O. B WAILUKU HI 96793 ANCHORAGE AK 99501 tOSEMEAD CA 91770

)

TONER 1 NORDLING, REG'T ENGINEERS TRANS-ASIA ENGINEERING ASSOCIATES I TRANSPORTATION, DEPARTMENT OF 4RC LIC. #:

50-18043-01 HRC LIC. #:

56-19185-01 HRC LIC. #:

36-13336-01 l0NSTRUCTION DEPARTMENT (MATERIALS P.O.

BOX 7924 FEDERAL HIGHWAY ADMINISTRATION 5.0.

BOX 570 TAMUNING GU 96911 222 S. W. MORRISON STREET ROOM JUNEAU AK 99801 PORTLAND OR 97204 4

w-__

jHION OIL COMPANY OF CALIFORNIA URANEX CORPORATION UECO INCORPORATED RC LIC. #:

50-16832-01 MRC LIC. 3:

04-17770-01 NRC LIC. 3:

50-19127-01 q:NION CHEMICALS DIVISION 17972 SKY PARK CIRCLE, SUITE C 5151 FAIRBANKS STREET

. O. BOX 575 IRVINE CA 92714 ANCHORAGE AK 99503 ENAI AK 99611 lASHINGTON PUBLIC POWLR SUPPLY SYST WILLIAM HEE & ASSOCIATES INC.

{RCLIC.

46-17964-G1 NRC LIC. 3:

53-19052-01 PPSS NUCLEAR PLANT NO. 2 1020 AUAHI STREET, SUITE NO. 1

.0.

BOX 968 HONOLULU HI 96814 ICHLAND WA 99352 B

w

+

.~

~n;;:~

sy j

a w

.m mp-

.... e n

g.

g'

'A

%g,;;,

g2 s

February 9, 1982 Gentlemen:

The enclosed notice is sent for your information.

It provides revised information about an event (case 2) that was included in the previously issued IE Information Notice No. 81-37.

If you have any questions related to this subject, please contact this office.

Sincerely, IMg.hthns v.

R. H. ErgeRen R. H. Engelken Regional Administrator

Enclosure:

IE Information Notice 81-37. Rev. I s

~u>......R W,,[hg,$,,

,,, 3 4 f,,,

"a-P

......IHQMA,S/,dA,

,,{, BOOK,,,,,,,,SP,Efs.E.R,

,,,,EfjGE(K,EN,

.... [/8,2 2/7/82 2/F/82 2/7/82 2/

omp N4C FORM 318 hoe 00l NRCM O240 OFFICIAL RECORD COPY

"" "- 2n:4

~

SSINS No.:

6835 Accession No.:

8107230049 IN 81-37, Rev. I UNITED STATES NUCLEAR REGULATORY COMMISSION 0FFICE OF INSPECTION AND ENFORCEMENT WASHINGTON, D.C.

20555 February 9,1982 4 -

IE INFORMATION NOTICE NO. 81-37, Rev.' 1:

UNNECESSARY, RADIATION EXPOSURES TO THE PUBLIC AND WORKERS DURING EVENTS INVOLVING-THICKNESS AND LEVEL MEASURING DEVICES Puroose:

Licensees holding byproduct material licenses have 'recently received IE Information Notice No. 81-37 dealing with unnecessary _ radiation exposures to the public and worke.s during events involving thickness.and level measuring devices.

Further NRC staff review of the circumstances: of.. Case 2 suggests that licensees using measuring devices may not always be totally familiar with their licensed devices and associated equipment. ~Thi's supplemental information is intended to reemphasize the need to assess the capability or the device to maintain full integrity in adverse environments--in this case, a high-temperature environment. Additionally, associated equipment, the radiation detector in this case, would have shown that the radioactive source was not fully shielded. This information should be brought to the attention of all persons involved in the administration and operation of the facilities using licensed measuring devices.

Descriotion of Circumstances (Case 2):

In Case 2, a level measuring device containing a 10 curie cesium-137 sealed source was subjected to a high-temperature environment that resulted in a melt-down and loss of the lead shielding.

Subsequent to this event, 31 individuals received unnecessary radiation exposures ranging from 0.14 to 3 rems while the unshielded source remained undiscovered.

During a four-day period, the radia-tion detector, which was part of the process equipment, showed that the source was not shielded; however, no one had noted this condition.

This information is intended to remind licensees about the importance of being familiar with the construction and installation of their measuring devices and '

to take full advantage of associated equipment, such as radiation detectors, that may be part of the process.

No written response to this notice is required.

If you need additional information about this subject, contact the Regional Administrator of the aporcoriate NRC Regional Office.

Attachment:

Recently issued IE Information Notices e

f

0 Attachment IN 81-37, Rev. 1 February 9, 1982

'RECENTLY' ISSUED IE INFORMATION-NOTICES-Infonnation Date of Notice No.

Subject Issue Issued to 82-02 Westinghouse BFD Relay.

N27/82 All power reactor Failures in Reactor Pro-~

facilities holding tection Systems 'at Certain an OL or CP Nuclear Power Plants R

'82-01 Auxiliary Feedwater Pump 01/22/82-All power reactor Lockout Resulting from

_ facilities holding Westinghouse W-2 Switch -

an OL or CP Circuit Modification 81-39 EPA Crosscheck Program -

12/23/81 All power reactor Low Level Radiciodine in facilities holding Water Test Program an OL or CP 33 Potentially Significant 12/16/81 All power reactor Equipment failures Resulting facilities holding from Contamination of Air-an OL or CP Operated Systems 81-37 Unnecessary Radiation 12/15/81 All power reactor Exposure to the Public and facilities holding Workers during Events-byproduct material Involving Thickness and

_ licenses Level Measuring Devices 81-36 Replacement Diaphragas for 12/3/81 All power reactor Robertshaw Valve (Model facilities holding No. VC-210) an OL or CP 81-35 Check Valve Failures

.12/2/81 All oower reactor facilities holding an OL or CP 81-34 Accidental Actuation of 11/16/81 All power reactor Prompt Public Notification facilities holding System an OL or CP 81-33 Locking Devices Inadequately 11/9/81 All powe.r reactor Installed on Main Steam facilitie3 holding Isolation Valves an-OL or CP OL = Operating License CP = Construction Permit

@