Text
,
,e w
e February 8, 1982
//, Cl;V/
'a v g Docket No. 70-1308 C/
, '.]
Y:a t
'1 n d,,2 219 gps -
iC General Electric Company
., :.g@/a re,M' s ATTN:
Mr. J. E. Van Hoomissen
' \\
I'.
Manager, Spent Fuel
- A Services Operation
'?y/'[pgih[7',
175 Curtner Avenue
'b San Jose, CA 95125
~
Gentlemen:
Enclosed is an addendum to I.E. Inspection Report No. 70-1308/81-01 transmitted by our letter dated March 4, 1981. The addenduc consists of a Confirmatory Measurements Program sheet comparing the results of analysis of alpha and beta activity in a liquid waste sample collected during the inspection on February 18, 1981, at your plant. This sample was analyzed by the NRC Refe rence Laboratory.
Please attach the addendum to your copy of our inspection report.
We will gladly discuss any questions you have regarding this addendum.
Sincerely, H
. A. Hind, Director Division of Emergency Preparedness and Operational Support Endlosure: Addendum to IE Inspection Report No. 70-1308/81-01 cc w/ encl:
DMB/ Document Control Desk (RIDS)
ITIh RIII RI}t/e2
+/~
%I Spcumacher RIII RIII Oestmann/so Gradt P
riello k
,i$
2/8/82 2p 9
- ///' /2.
8202160577 820208
~
PDR ADOCK 07001308 s/
C PDR
ATTACIN1:NT 1 CRITERIA FOR COMPARING ANALYTICAL MEASURDIENTS This attachment provides criteria for comparing resnits of capability tests and verification measurements.
The criteria are based on an empirical relationship which combines prior experience and the accuracy needs of this progrim.
In these criteria, the judgment limits are variable in relation to the comparison of the NRC Reference Laboratory's value to its associated one sigma uncertainty. As that ratio, referred to in this program as
." Resolution", increases, the acceptability of a licensec's measurement should be more selective.
Conversely, poorer agreement should be con-sidered acceptable as the resolution decreases.
The values in the ratio criteria may be rounded to fewer significant figures to maintain statistical consistency with the number of significant figures reported by the NRC Reference Laboratory, unless such rounding will result in a narrowed category of acceptance.
The acceptance category reported will be the narrowest into which the ratio fits for the resolution being ut.d.
~
RESOLUTION RATIO = LICENSEE VALUE/NRC REFERENCE VALUE Possible Possible Agreement _
Agreement "A" Agreeable "B"
~
<3 No Comparison No Comparison No Comparison
>3 and <4 d.4 2.5
- 0. 3
- 3.0 No Comparison T4 and <8 0.5 -
2.0 0.4 2.5 0.3
- 3.0 78 and <16 0.6 - 1.67 0.5
- 2.0 0.4
- 2.5 T16 and <51 0.75 - 1.33
- 0. 6
- 1.67 0.5
- 2.0 1.33 0.6
- 1.67 I51 and <200 0.80 - 1.25 0.75
.3200 0.85 - 1.18 0.80 - 1.25 0.75 -
1.33 "A" criteria are applied to the following analyses:
Gamma spectrometry, where principal gamma energy used for identifi-cation is greater than 250 kev.
Tritium analyses of liquid samples.
"B" criteria are applied to the following analyses:
Camma spectrometry, where principal gamma energy used for identifi-cction is 1 css than 250 kev.
Sr,-89 and Sr-90 determinations.
Cross beta, where samples are counted on the same date using the
- same reference nuclide.
9 e
F
"-HO e a
s TABLE I U S NUCLEAR REGULATORY COPMISSION OFFICE OF INSPECTION AND ENFORCEMENT CONFIRMATORY MEASUREMENTS PROGRAM FACILITYt GE MORRIS FOR THE 1- 0UARTER OF 1981
NRC-------
---LICENSEE-----
---NRCtLICENSEE----
SAMPLE ISOTOPE RESULT ERROR RESULT ER60R RATIO RES T
L WASTE ALPHA 0.0 1 0E-09 6'. 0 E - 10 0.0 0.0 0.0 N
BETA 2 3E-08 5 0E-09 1.2E-08 2 1E-09 5.2E-01 4.6E+00 A
T TEST RESULTS A= AGREEMENT D= DISAGREEMENT P=POSSIBLE AGREEMENT N=NO COMPARISON 4
b 6
s B
e G
4 b
e 1
0 r,.
m y
..