TSP-3 Attr.chment-2 Issue 2 OPERATING DATA REPORT DOCKET MO.

50-267 DATE 820208 CoreLETED sr L. M. McBride TELEPs0NE 785-2224 OPERATING STATUS

\\

.m 1.

Unit Name:

Fort St. Vrain 2.

Raporting Period:

820101 *.hrough 820131 3.

Licensed Thermal Power (Mit):

842 4.

Nameplace Racing (Cross W e):

342 5.

Design Electrical Rating (Net We):

330 5.

Maximum Dependable Capacity (Gross We):

342 7.

Maximum Dependable Capacity ()let We):

330 8.

If Changes Ocaur in Capacity Ratings (Icesa Number 3 Through 7) Since Last Report, Give Reasons:

None 9.

Power Level To Which Restricted, If Any (Net We): 231 10.

Raasons for Restrictions If Any:

NRC restriction of 70% pending resolution of temoerature fluctuations.

This Month Year to Date Cumulative 11.

Pours in Reporting Period 744.0 744.0 22,705

12. Number of Hours Reactor Was Critical 0.0 0.0 14,578.4 13.

Reac'.or Reserve Shutdown Hours 0.0 0.0 0.0 la. aours Generator on-Line 0.0 0.0 9.908.3

15. Unit Reserve Shutdown Hours 0.0 0.0 0.0 16.

Cross Thermal Energy Generated (mm) 0.0 0.0 4.933.944.8

17. Cross Electrical Energy Genersted (51) 0.0 0.0 1.691.356 13.

Net Electrical Energy Generated (WR)

-1_450

-I.950 1.552_309 19.

t' nit Service Factor 00 0O 41.6 20.

Unit Availability Factor 0.0 0.0 43.6 l

l

21. Unit Capacity Factor (tsing MDC Net) 0.0 0.0 20.7 22.

Unit Capacity Factor (Using DER Net) 0.0 0.0 20.7

23. Unit Forced Outage Rate 0.0 0.0 34.0 24.

Shutdowns Scheduled over Next 6 Months (Type, Date. and Duracion of Each): Maintenance /

i mod Hicntion shutdown 2-1-82 throuch 2-28-82.

25.

If Shut Down at End of Report Period, Estimated Date of Startups March 1, 1982 26.

Units In Test Status (Prior to Commercial Operation):

Forecast Achieved INInAL CRIUCALITY N/A N/A I::ICAL ELECTRICITY N/A N/A CO:ffERCTAL OPERATION N/A N/A B202160514 820210 PDR ADOCK 05000267 R

PDR

TSP '

Attachmnc-3A AVERAGE DAILY UNIT POWER LEVEL Issue 2 Page 1 of 1 Docket No.

50-267 Unit Fort St. Vrain Date R20208

' Completed By. L. M. McBride Telephone 785-2224 Month January, 1982 DAY AVERAGE DAILY POWER LEVEL.

DAY AVERAGE DAILY POWER LEVEL.,

(MWe-Net).

(MWe-Net) 1 0.0 17 0.0 2

0.0 18 0.0 3

0.0 19 0.0 4-0.0 20 0.0 5

0.0 21 0.0 6

0.0 22 n_n

' 7 0.0 23 0.0 8

0.0 24 0.0 9

0.0 25 0.0 10 nn 26 0.0 11 0.0 27 0.0 l

12 0.0 28 0.0 13 0.0 29 0.0 14 0.0 30 0.0 15 0.0 31 0.0 l

l 16 0.0 I

l l

  • Generator on line but no net generation.

w-N--

-' +

, g g

--y,- -,.,., - -

9

.y 9

e-wy y

9,-.,.r w

yw T1y w--

y 8

r-W y

y fr' wevt-y-

~wir w

yeww

C

)"

E I

C t

N n

f E

e o

N m2 R

e 1

U 3de n

X

- aie t

Pt sg R

St oa n

tat P T

i e

N a

d E

r i

VE V

r R

B P

n c

s o

t M

2 t

o 7

S 8

1 i

N 6

0 2

O t

2 t

2 M

I a

r 0

5 T

c C

0 o

2 8

A i

5 F

8 L

7 f

E i

V d

I T

o C

m E

E v

F.

E o

M T

s N

R R

N A

A O

)

t N

n D

H T

E P

G i

c I

T E

l E

T D

p r

E.

R N

M 1

n u P

T A

s 9

i M

O E

p C

SU o

A o

C L

TNE X

N X

OFE X

D X

00)

C0 XX M

ETE I

SD B

YO S-SC C

N 2

C-O 8

T 9

U 1

D-E R-

.y RE-r a

W-O-

u A

P n

/

D a

N N

J A

S I

N l

R W

l m

E.

0 1

W I

T R

U P

H F

S T

OG T.

R N

R O

DI O

I P

OT T

N E

MTNC 2

U.

R 1 Ud A n

F. H i E MSDR NO SA B

E R

0 N

O I

T 4

A 4

R 7

UD E

S P

YT 1

0 E

1 T

0 A

2 D

8 6

O.

2 0

1 N

8

h E

a

L"Cl!I.*NG I3/CRMAT*03 1.

Name of Tec1110r.

Fort St. Vrain Uni: No. 1 2.

Scheduled date for nex: refueling shutdown.

October 1, 1983

^

3.

Scheduled date for restarn following refueling.

Seco-her i_ lost 3 4.

Will refueling or resumption of operation thereafter require a

= 4M"t specificacion change or other license==ncimanc?

Yes If answer is yea, what, in tener21, will these be?

Use of type H-451 graohite.

If answer is so, has the reload fuel design and core configura-

1on been rerieved by your Plan:

Safety Review Commi::ee to deter-sine whether any unreviewed safety questions are associated w1:h the core reload (2eference 10Cn See:1on 50.59)?

l

:o such review has taken i

olace, when is 1: schedded?

l 5.

Scheduled da:e(s) for submi::1ng t

proposed licensing action and succerting i=for=acion.

Not scheduled at this t!te: to be determined.

6.

Inpor:anc licensing considera-c1ans associated w1:h refueling, e.g., new or different fuel de-sign or supplier, unreviewed design or perforsence analysis

sechods, significane changes in fuel design, new operactsg pro-cadures.

7.

The number of fuel assemblies 1482 3:GR fuel ele =ents (a) in the core and (b) in 250 spent GR fuel elenants s.

the scene,.nel storage cool.

3.

he presene. licensed spent fuel pool scorage capac1:7 and :he Capac1:7 is li=1:ad in size :s about one-l l

sima of any increase in licensed third of core (approximacaly 300 ETGR storage capaci.7 :ha: has 'oeen elesen:s), No change is planned.

requested or is planned, in nunber of fuel assemblies.

.-.. a REFUELIT, INFORMATION (CONTINUED) 9.

The projected date of the 1986 under the Three Party Agreement (Con-last refueling that can be tract AT (04-3)-633) between DOE, Public j

discharged to the spent fuel Service Company of Colorado (PSCo), and pool assuming the present General Atomic Company.*

licensed capacity.

  • The 1986 date is based on the understanding that spent fuel discharged during the term of the Three Party Agreement will be shipped to the Idaho National Engineering Laboratory for storage by DOE at the Idaho Chemical Processing Plant (ICPP). The storage capacity has evidently been sized to accomodate fuel which is expected to be discharged during the eight year period covered by the Three Party Agreement.

1 1

.