, _ _ _.

POWER AUTHORITY OF THE STATE OF NEW YORK to CotuMaus CIRCLE NEW YORK. N. Y.1o019 t 21' ne 7.6 200 G eor,agt eERRy TRUSTEES opt st AYIN G oF FIC a n JOHN S DYSON JOHN W. BOSTON PRE IDEN, ROCEDURLS

  • ""*'0""""C" GEORGE L. iNG ALLS vics CMal4M AN JOSEPH R. SCHMIEDER Png. DE a CHIEF RICH ARD M. FLYNN RosERT e. miLLONzi February 4, 1982

!Jco","*ci^%,,,or,,,

PRE oERic x R. c'^""

JPN-82-14

,6.Ll. >.

Director of Nuclear Reactor Regulation

..., CY,.. 7e.,

United States Nuclear Regulatory Ccmmission

      • {k -

Washington, D.C.

20555 NC

~ J.O 9

2g

~

4q k

Attention:

Mr. Domenic Vassallo, Chief ga Operating Reactors Branch No. 2 p/

Division of Operating Reactors

'Q Af

Subject:

James A. FitzPatrick Nuclear Power Plant p

Docket No. 50-333 N

Decreased Control Rod Drive Scram Surveillance Frequency

References:

(1) Letter, J.

P. Bayne (PASNY) to T. A.

Ippolito (NRC) dated November 18, 1981 - Proposed Changes to the Technical Specifications Regarding Reload 4/

Cycle 5.

Dear Sir,

Attached is a report entitled " Evaluations of the effects of Corrosion Particles on Control Rod Drive Operation at the James A.

FitzPatrick Nuclear Power Plant, "which is submitted in sup-port of the Reload 4/ Cycle 5 Technical Specification Amendment (Reference 1).

This report provides technical justification for these Technical Specification changes to reduce the Control Rod Drive (CRD) surveillance frequency from the present fifteen-per-cent of operable drives at 8-week intervals, back to the original requirement of ten-percent of the operable drives at 16-week in-tervals.

The report also evaluates the potential impact of carbon steel corrosion particles on the scram reliability of the CRD system during operation without the use of the CRD exhaust header filters recommended by General Electric in their Service Information Let-ter No. 200.

The evaluation indicates that operation without the exhaust header filters does not affect the reliability of the CRD scram function.

po/

,Very truly yours, y

/<[ ~ :(fQ

  1. I m

(

. naytib1

^

'~

l U Senior Vice President Nuclear Generation cc enclosed

' 8202090271 820204 PDR ADOCK 05000333 P

PDR

. o 4:

+

4 cc:

Mr. J. Linville i

Resident Inspector U. S. Nuclear Regulatory Commission j

P. O. Box 136 l

Lycoming, New York 13093 3

-Mr.

Ron Barton

,,l-United Engineers & Constructors, Inc.

30~S. 17th Street' l-Philadelphia, PA 19101 1

l 4

9 1

4 j

i 3

J J

f 5

1

-.rm or

,~m.m.~,-.--,

.1-

_..+m..-, _ - -.. _, - - - - -

_ _, -