i 6., ' f, y

ja Mou g

p UNITED STATES g

y i 1,.t g

NUCLEAR REGULATORY,COMMI SION S

g."

C WASHINGTON. D, C. 20555 o,f

[f January 25, 1982 a

y

,y s

Docket No. 50-537 s

APPLICANT:

Departcent of Energy FACILITY: ' Clinch River Breeder Reactor

SUBJECT:

SUMMARY

OF J M UARY 15, 1982 CRBR REVIEW MEETING A meeting was held on January 15,1982 dn' Bethesda, Md. to discuss sodium-concrete reactions. The applicant described'the results of all sodium-concrete interaction test data to date. Twenty-two sodium-concrete tests were reviewed.

The test results varied greatly. Specifically, the total concrete penetration

~-

ranged from zero to seven and one-half inches. The penetration rates also varied from zero to ten inches per hour.

However, the high penetrazion rates were short-lived.

The applicar,t then discussed the sensitiv'ity of high concrete' penetration rates on the cantainment integrity and radiological doses. The results, although still preliminary,'show that containment integrity 4 maintained and that offsite doses are within 10 CFR siOO limits.

~

The applicant then"dsscribad tneir plans to conduct additional sodium-concrete interaction tests in"an., effort to cbtain more test data and to better understand sodium-concrete phenomenology.

The meeting attendee listing-is attached to this summary.

N e

l n

i Richard M. Stark, Project Manager CRBR Program Office V

Office of Nuclear Reactor Regulation 1

s s

s

Enclosure:

t l

As stated s-

. t

'\\

cc:

Service Lis't g

xl s

h.

g j

l y

i c

t i

s i

t 820208dOb1 ' 20125 PDR ADCCK 05000537 i*,

A PDR m

3

[

A s

cc:

Dr. Cadet H.' Hand, Jr., Director Barbara A. Finamore q ;f -

Bodega Marine L2boratory S. Jacob Scherr University of California Ellyn R. Weiss b J' P. 0.'Bux 247-Dr. Thomas B. Cochran Bodega Bay, California 9.4923 Natural Resources Defense Council, Inc.

~

1725 I Street, N.W.

Daniel Swanson Suite 600 Office of'the Executive Washington, D.C.

20006 Legal, Director

,/,

U. S. Nuclear Regulatory Conunission Washington, D.C.

20555 4

William B. Hubbard, Esq.

a Assistant Attorney General State of Tennessee Office of tiie' Attorney General 422 Suprere' Court Building i

Nashville,'TN 37219 Luthsr M. Reed, Esq.

s Attorney for the City of Oak Ridge 253 Main Street, East Oak Ridge, TN 37830

~

George L. Edgar, Esq.

Morgan, Lewis & Bockius 1800 M Street, N.W.

20036

'pashing+on, D.C.

'Hirbert S. Sanger, Jr., Esq.

General Counsel Tennessee Valley Authority Knoxville, TN 37902 Chase Stephens, Chief Docketing and Servica Section I'0ffice of the Secretary I U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Raymond L. Copeland Project Management Corp.

P. O. Box U Oak Ridge, Tennessee 37830 L. Ribb LNR Associates Nuclear Power Safety Consultants S605 Grimsby Court Potcmac, MD 20854

e January 15, 1982 Sodium-Concrete Interaction Meeting-Richard Stark NRC Bethesda Piiillip Bradbury Westinghouse Oak Ridge Dave Goeser Westinghouse Bethesda George Clare Westinghouse Oak Ridge Lee Strawbridge Westinghouse Waltz Mill Joel Siegel P0 Oak Ridge Arlin Postura HEDL Harford R.K. Hilliard HEDL Richland Ed Purvis DOE Germantown Wayne Pasko CRBR-Project Office Oak Ridge Stephen Additon Westinghouse Dethesda Shakir Zaman Burns & Roe Oradell, N.J.

Robert Palm Burns & Roe Oradell, N.J.

T.W. Ball Westinghouse Waltz Mill P. Wu NRC Bethesda L.N. Rib LNR Associates Potomac, MD J. Cong NRC Bethesda D.G. Swanson Applied Science Ass.

Palos Verdes, CA D.A. Powers Sandia National Labs.

Albuquerque, N.M.

Bill Morris NRC CRBRP0 H.B. Holz NRC CRBRP0 L.S. Tong NRC RES Rob Woolley DOE Germantown D. Ujifusa DOE Germantown-T.J. Walker NRC

-S S. RES C.L. Allen NRC CRBRP0 4

"N i

JAN 2 51982 Docket lio. 50-537 APPLICAt4T: Department of Energy FACILITY:

Clinch River Breeder Reactor

SUBJECT:

SUMMARY

OF JAttUARY 15, 1982 CRBR REVIEW MEETI!4G A meeting was held on January 15, 1982 in Bethesda, Md. to discuss sodium-concrete reactions. The applicant described the results of all sodium-concrete interaction test data to date. Twenty-two sodium-caecrete tests were reviewed.

The test results varied greatly. Specifically, the total concrete penetration ranged from zero to seven and one-half inches. The penetration rates also varied from zero to ten inches per hour. However, the high penetration rates were short-lived.

The applicant then discussed the sensitivity of high concrete penetration rates on the containment integrity and radiological doses. The results, although still preliminary, show that containment integrity is maintained and that offlite dosessare within 10 CFR 100 limits.

The applicant then described their plans to conduct additional sodium-concrete interaction tests in an effort to obtain more test data and to better understand sodium-concrete phenomenology.

The neetii.g attendee listing is attached to this summary.

4 Original signed by:

Richard M. StW-Richard it. Stark, Project Manager CR8:1 Program Office Office of fluclear Reactor Regulation

Enclosure:

As Stated cc: Service List 7)AtS

..CRBRM....j:.NR..R CR RP0 p' orr,co

.g.;..

... g sua~ m >

..l. /.N.................L8 2,.......,

.)

g......,

om>

OFFICIAL RECORD COPY uso n.-m.,eo sac ronu :na no-soy nacu oua

Distribution Docket Eile' bec:

Applicant 3ervice List NRC PDR Local PDR CRBRPO File NSIC H. Denton D. Eisenhut-

/r ~'

R. Vollmer R. Mattson S. Hanauer

/

I' Y9 H. Thomosan

[

h J. P. Knight

/I

D
,.,l"l4 jde,

T I

LO W. Johnston

~

~, EFT a

D. Muller N

P. Check

"/d j;/

s W. Kreger (N

/

L. Rubenstein bl

/p

~~

F. Schroeder M. Ernst ACRS (16)

OI&E (3)

S. Treby (OELD)

J. LeDoux, I&E V. Moore B. Grimes C. Thomas P. Leech P. Stark W. H. Foster R. Wcodruff B. Morris I&E Region II ED0 (4)

L. S. Tong Licensing Assistant - P. Shuttleworth NRC Participants J. A. Olshinski, IE: Reg. II R. E. Irelanc, NRC-Idaho J. Austin

.B. D. Liaw J. Glynn P. Wood

.