ea-a 21-S/10 M%d 4 /MMfE DEC 3 0198; 3%-D FCTC:WHL 71-5170 n..

y%.,

o

.9 HECEr&D s3 tq JAN 71982> E j t e. e.,, e'u U.S. Department of Energy g% Es;;U, ATTN: Dr. Donald M. Ross MS-E-201 Washington, DC 20545

IIM5 ~ ~

Gentlemen:

This refers to the Safety Analysis Report for Packaging (SARP), submitted on April 4,1975 requesting our review of the Model Nos. Steel Ingot Skid and Box No.~37 packages.

We have reviewed the approach and methods used to demonstrate that the J

proposed packaging and contents meet the requirements of 10 CFR Part 71.

J In connection with our review, we have' identified some basic issues that

.need to be resolved.

We agree with the approach of assuring subcriticality of the shipment by limiting the fissile material to a safe mass based on optimum moderation of the contents following the accident damage tests. However, it should be shown that the criticality analysis reported in Appendix B of Report No. RMI-L-67i August 1974, is applicable and justifies the safe mass limit of 18,100 kg of uranium enriched to 1.25 w/o U-235 for a minimin dimension of two inches (i.e., 2-inch diameter rods).

The physical form of the contents should be addressed following the accident damage tests.- It has not been shown that oxides or any interim mix of oxides and metal is less reactive than the uranium metal or that formation of oxides would be precluded. Also, provide verification that uranium pieces subject to the thermal test of 1475'F for 30 minutes will not completely oxidize.

8202040065 811230 PDR ADOCK 07105170 C

PDR

  • mC' >

oarr >

nac ronu ato cio-so> Nacu o24o OFFICIAL RECORD COPY

.J

O U.S. Department of Energy DEC 3 01931 Please advise us within thirty (30) days from the date of this letter when the above information will be provided.

Sincerely, Origin:a Mcnod by cwri.s E. ucDom14 Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS cc: DOE, Oak Ridge Operations Office ATTN: Mr. William H. Travis P.O. Box E Oak Ridge, TN 37830 Distribution:

WHLake RH0degaarden Docket File

NRC PDR IE HQ (3)

NMSS R/F FCTC R/F HWLee

,r) c'ncc>

. F.919....

...R,

11...,RHodegaarden..CEMacDonald.

oan >

l..'l..... /. 81

......&...o / 81

..... 30/81 12 12/

o

...4..

l ~=c ro.