ML20040B625
| ML20040B625 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse |
| Issue date: | 01/18/1982 |
| From: | Crouse R TOLEDO EDISON CO. |
| To: | Stolz J Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20040B626 | List: |
| References | |
| 767, IEB-79-14, NUDOCS 8201260259 | |
| Download: ML20040B625 (3) | |
Text
.
.. +.. - -
TOLEDO
%em EDISON Docket No. 50-346 vu nn t
License No. NPF-3 Nw Serial No. 767
'"fM
- x h'
January 18, 1982 s.
D-l 7
~.
a e.
;jzb j..
g
~ ~~~
?.
e y
Director of Nuclear Reactor Regulation d
N) g(/
Attention:
Mr. John F. Stolz Operating Reactor Branch No. 4 Division of Operating Reactors United States Nuclear Regulatory Commission Washington, D. C.
20555
Dear Mr. Stolz:
Under separate cover, we are transmitting three (3) origine!.:nd forty (40) conformed copics of an application for Amendment to Fac11 tty Operating License No. NPF-3 for the Davis-Besse Nuclear Pwer Station Unit No. 1.
This application requests that the Davis-Besse Nuclear Power Station Unit 1 Technical Specifications, Appendix A, be revised to reflect the changes attached. The proposed changes involve Table 3.7-3.
The attach-ments identify a snubber which was replaced upon reevaluation of the seismic analysis for safety related piping in accordance with I.E.
This amendment request involves a change of Class II type.
Enclosed is a check for $1,200 as requested by 10CFR170.22.
Very truly yours, l ff' W ~
Attachments
/
It wdde cc:
l Dil-1 NRC Resident inspector
'y poo.es l
l ht b/l THE T L in na a v c nie na, n.. "
300 MAD: SON AVENUE TOLEDO. OH!O 43652 PDR ADOCK 05000346 P
APPLICATION FOR AMENDMENT TO FACILITY OPERATING LICENSE NO. NPF-3 FOR DAVIS-BESSE NUCLEAR POWER STATION UNIT NO.'l Enclosed are forty-three (43) copics of the requested changes to the Davis-Besse Nuclear Power Station Unit No. 1 Facility Operating License No. NPF-3, together with the Safety Evaluation for the requested change.
The proposed changes include Table 3.7-3.
R. P. Crouse By Vice President, Nuclear Sworn and subscribed before me this
' day of January, 1982 C
N w (f.
~
Notary Public LAURIE A. BRUDZINSKI Notary Public. State of h My Commisman Empires May it.1984 l
2
Docket No. 50-346 License No. NPF-3 Serial No. 767 January 18, 1982 Attachment I.
Change to Davis-Besse Nuclear Power Station Unit 1, Appendix A j
Technical Specifications, Table 3.7-3 j
A.
Time required to Implement This change is to be effective upon NRC approval B.
Reason for Change (Facility Change Request 81-203)
Evaluations performed for IE Bulletin 79-14 showed that snubber 33A-GCH-4-ll5 could be replaced with a sway strut. The snubber was replaced, therefore the Technical Specifications Table 3.7-3 should be revised to reflect this change.
C.
Safety Evaluation A reevaluation of the seismic analysis for safety related piping system (IE Bulletin 79-14) showed that snubber 33A-GCB-4-il5 could be replaced with a sway strut. The safety function of hydraulic snubbers is to ensure that the structural integrity of the reactor coolant syr. tem and all other safety related systens is maintained during and following a seismic or other event initiating dynamic loads.
The evaluation revealed minimal hot and cold setting dif ferences for Emergency Core Cooling System snubber 33A-GCH-4-il5. As a result, the snubber was removed and replaced with a sway strut.
The safety function of the snubber is now accomplished by the sway strut.
Therefore, this is not an unreviewed safety issue.
---