Final Part 21 Rept Re Undersized Socket Welds on Piping of safety-related Skid Mounted Equipment,Originally Reported 791129.Weld Repair on Emergency Feedwater Pumps Completed. All Other Equipment Qualified
ML20040B468
Person / Time
Site: Summer 
Issue date: 01/13/1982
From: Nichols T
SOUTH CAROLINA ELECTRIC & GAS CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-82-551-000 10CFR-50.55E, 81-28-03, 81-28-3, PT21-82-551, PT21-82-551-000, NUDOCS 8201260080
Download: ML20040B468 (2)


Text

--

G o

M' y/RC R e r,,, H

. lr, rp

~

SOUTH CAROLINA ELECTRIC argas C' MPANY l

4 ros, o,,.c. oo, m Cotu@A, p H ARO IN 29218

  • hN T. C. N acwo ts, Ja wet Pers ties a.o Gnoop Carcutivt January 13, 1982

\\ ;

j N

'v' -

Mr. Jams P. O'Reilly U. S. Guclear Regulatory Conmission P

Region II, Suite 3100

' ~ "

iP? s 101 Marietta Street, N. W.

1

/

Atlanta, Georgia 30303 N

A S.lbject: Virgil C. Sunmer Nuclear Station Docket No. 50/395 Socket Weld Inspection of Skid j

Mounted Equipnent i

Open Item 81-28-03 i

Dear Mr. O'Reilly:

1

{

In a letter to you frcm G. C. Meetze of South Carolina Electric & Gas Wmpany j

(SCE&G) dated November 29, 1979, a catmitment was made to inspect and review j

the socket wlds made by vendors on piping of safety related skid mounted l

- equipnent. An inspection of the following equipnent for undersized socket i

welds has been conducted by SCE&G Construction QC:

Cantonent Cooling Water Pumps Emergency Ebalwater Pumps i

Diesel Generator Appurtenances l

Diesel Ebel Oil Transfer Pumps l

Reactor Building Spray Pumps Service Water Pumps l

Service Water Booster Pumps i

Chillal Water Pumps J

G illers Charging / Safety Injection Ptunps a

RHR Pumps Waste and Recycle Evaporators a

Waste Gas Canpressors Catalytic flydrogen Reconbiner The Canponent Cooling Water Durrps, Diesel Ebel Oil Transfer Pumps, Reactor Building Spray Pumps, Service Water Pumps, Service Water Booster Pumps, Chillai Water Pumps, and Gillers were found to have no safety related socket weldal piping. Socket welds associatal with the RilR pumps as well as one of 8201260080 820113 PDR ADOCK 05000395

.t q g

PDR L CSQ

%i1 M

~.

Mr. James P. O'Reilly January 13, 1982 Page Two the Ilydrogen Reconbiners wre found to be acceptable. W e Energency medwater Pumps, Diesel Generator Appirtenances, Charging / Safety Injection Pumps, Waste and Recycle Evaporators, Waste Gas Qxnpressors, and one Catalytic Ilydrogen Reconbiner were found to have deficient socket welds. Nonconformance Notices (NCN's) -1343M, -1348M, -1342M, -1393M, -1392M, and -1391M respectively were generatal as a result. These NCN's which specifically identified the deficient welds and their size, were utbnitted to their respective manufact.urers for evaluatica and a tion. With the exception of the anergency Nodwater Pumps, each nunufacturer was able to parform an analysis and danonstrate that the as-weldal conditions are adequate to withstand the equipnent's respective design loads. Based on these analyses, the disposition of NCN's -1342M, -1348M, -1391M, and -1393M were made to accept the nonconforming conditions as-is.

'Ihrough telephone conversations with Westinghouse, we understand that a letter is forthcaning stating that the Waste Csis Qxnpressor is acceptable. We expect to receive that letter and disposition NCN-1392M to accept as-is by January 29, 1982.

We manufacturer of the Emergency Rulwater Pumps could not qualify the existing conditions. Subsequently, a Substantial Safety llazard was declaral under the trovisions of 10CFR21. A final retort was subnittal to you by my letter dated Septanber 14, 1981, in which it was statal that corrective action was to add weld material to the deficient joints. Wis weld repiir has been canpletal by SCE&G under the rules of Section XI of the ASMS Code. Ibcununt packet revision is in trogress by SCE&G Nuclear Operations QC and is anticipatal to be canplete by January 29, 1982.

With respect to our cannitment to inspect socket welds on skid mowital equipnent, this is a final report and the issue of undersizal socket welds is consideral canplete.

If you require further information please alvise.

Very truly yours, y

j pri

./

T. C. Nichols, Jr.

GIN:'IEN:glb cc:

Page Three i

I Mr. James P. O'Reilly January 13, 1982 Page Three cc:

V. C. Summer T. C. Nichols, Jr.

G. II. Fischer II. N. Cyrus II. T. Babb D. A. Nauman M. B. Whitaker Jr.