PHILADELPHIA ELECTRIC COMPANY 23O1 MARKET STREET P.O. DOX 8699 PHILADELPHI A. PA.19101 (215; 841 4o0o January 13, 1982 Mr. R. C. Haynes, Director Office of Inspection and Enforcement

~

N.

Region I U. S. Nuclear Regulatory Commission f

'N 631 Park Avenue

/

King of Prussia, PA 19406

\\

SUBJECT:

Peach Bottom Unit 3 - Inservice Inspection's i

/

Refs.: Technical Specifications 6.9.3.b,

/

4.6.G, and Tabl e 4.6.1

/

Dear Mr. Haynes:

a In accordance wi th the referenced Technical Speci fications, Inservice Inspections were completed on Unit 3 during the March 6, 1981 to October 23, 1981 Refueling Outage.

Enclosed are three copies of the Inservice Inspection Report which sunsaarizes the examinations performed.

Several indications (lack of penetration and linear) were iden-tified as a result of these examinations.

Their resolutions are contained in Attachment 2 of the report, "Cuntnary of Indications".

The ISI examination data has been reviewed by the PORC, the PECo Senior Engineer - ISI Section, and the Hartford Steam Boiler Inspection and Insurance Company Code Inspector.

The results of these reviews indi-cate that the ISI inspection requirements have been met satisfactorily.

In addition to the Inservice Inspection Report, a detailed data package has been assembled which supports this examination.

This package is re-tained by Philadelphia Electric Company, and is available for review.

Very trul y yours,

/ {/ l )' Qj if 'G f-

/

M. gJ ~. Cooneyf fSuperintendent

" Generation Division - Nuclear Enclosures cc:

Mr. Julius Clarr, Chief Inspector, Dept. of Labor & Industry Mr. Charles E. Berry, Chief Inspector, The Hartford Steam Boiler Inspection & Insurance Company 8201'220277 820113 PDR ADOCK 05000278 N O; G

PDR

I e

.-